Lucene search
+L

685 matches found

NVD
NVD
added 2012/02/03 8:55 p.m.25 views

CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

7.1CVSS6.5AI score0.07527EPSS
Exploits0References8
NVD
NVD
added 2012/02/03 8:55 p.m.23 views

CVE-2011-4513

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

10CVSS7.5AI score0.04846EPSS
Exploits0References2
Prion
Prion
added 2012/02/03 8:55 p.m.17 views

Cross site request forgery (csrf)

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

8.5CVSS7.2AI score0.12545EPSS
Exploits0References8Affected Software3
Prion
Prion
added 2012/02/03 8:55 p.m.24 views

Authentication flaw

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

10CVSS7AI score0.03522EPSS
Exploits0References2Affected Software3
Prion
Prion
added 2012/02/03 8:55 p.m.27 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.9AI score0.01509EPSS
Exploits0References2Affected Software3
Cvelist
Cvelist
added 2012/02/03 8:0 p.m.35 views

CVE-2011-4514

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

6.4AI score0.03522EPSS
Exploits0References2
CVE
CVE
added 2012/02/03 8:0 p.m.64 views

CVE-2011-4511

CVE-2011-4511 is a cross-site scripting (XSS) vulnerability in the Siemens SIMATIC WinCC HMI web server. Affected products (per ICS-CERT) include WinCC flexible 2004/2005/2007/2008 (before SP3), WinCC V11 (TIA Portal) before SP2 Update 1, and multiple SIMATIC HMI panels plus WinCC V11 Runtime Adv...

4.3CVSS5.7AI score0.01509EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2012/02/03 8:0 p.m.60 views

CVE-2011-4510

CVE-2011-4510 and CVE-2011-4511 describe cross-site scripting (XSS) in the Siemens SIMATIC WinCC/HMI Web server. Affected products include WinCC flexible 2004–2008 (before SP3), WinCC V11 (TIA Portal) before SP2 Update 1, and multiple SIMATIC HMI panels, plus WinCC V11 Runtime Advanced and WinCC ...

4.3CVSS5.7AI score0.01509EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2012/02/03 8:0 p.m.31 views

CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexibl...

6.6AI score0.12067EPSS
Exploits0References8
CVE
CVE
added 2012/02/03 8:0 p.m.91 views

CVE-2011-4509

CVE-2011-4509 affects Siemens WinCC/WinCC flexible products (2004–2008, WinCC V11, and related SIMATIC HMI panels). The root cause is an improperly selected default administrator password, which enables remote attackers to gain access by brute-forcing via many HTTP requests. Public citations in c...

10CVSS6.7AI score0.0217EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2012/02/03 8:0 p.m.30 views

CVE-2011-4876

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is...

6.6AI score0.09847EPSS
Exploits0References9
CVE
CVE
added 2012/02/03 8:0 p.m.58 views

CVE-2011-4512

CVE-2011-4512 is a CRLF/header-injection vulnerability in the Siemens SIMATIC WinCC/HMI web server. Affected products include WinCC flexible 2004/2005/2007/2008 before SP3; WinCC V11 (TIA Portal) before SP2 Update 1; multiple SIMATIC HMI panels (TP/OP/MP/Comfort/Mobile); WinCC V11 Runtime Advance...

5CVSS6.9AI score0.01704EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2012/02/03 8:0 p.m.35 views

CVE-2011-4508

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication token...

6.6AI score0.03119EPSS
Exploits0References2
CVE
CVE
added 2012/02/03 8:0 p.m.64 views

CVE-2011-4876

CVE-2011-4876 is a directory traversal vulnerability in Siemens WinCC family runtimes (WinCC flexible 2004–2008, WinCC V11/TIA Portal, and related SIMATIC HMI panels) where the runtime loader HmiLoad fails to validate strings during Transfer Mode. This allows remote attackers to access or modify ...

9.3CVSS6.9AI score0.09847EPSS
Exploits0References9Affected Software1
Cvelist
Cvelist
added 2012/02/03 8:0 p.m.31 views

CVE-2011-4879

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

6.6AI score0.12545EPSS
Exploits0References8
Cvelist
Cvelist
added 2012/02/03 8:0 p.m.31 views

CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

6.5AI score0.07527EPSS
Exploits0References8
CVE
CVE
added 2012/02/03 8:0 p.m.61 views

CVE-2011-4513

CVE-2011-4513 affects Siemens WinCC Flexible (2004–2008), WinCC V11 (TIA Portal), SIMATIC HMI panels (TP/OP/MP/Comfort/Mobile), and WinCC Runtime Advanced/Flexible Runtime. The vulnerability allows user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the...

10CVSS7.8AI score0.04846EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2012/02/03 8:0 p.m.61 views

CVE-2011-4877

CVE-2011-4877 affects Siemens WinCC flexible products (2004–2008) and related SIMATIC HMI panels, WinCC V11 Runtime Advanced, and WinCC flexible Runtime. The issue lies in HmiLoad in the runtime loader; when Transfer Mode is enabled, sending crafted data over TCP can cause a remote denial of serv...

7.1CVSS6.7AI score0.07527EPSS
Exploits0References8Affected Software1
The Hacker News
The Hacker News
added 2012/02/02 6:43 a.m.18 views

Application Security With Apache Shiro : Java security framework

Application Security With Apache Shiro : Java security framework Are you frustrated when you try to secure your applications? Do you feel existing Java security solutions are difficult to use and only confuse you further? Les Hazlewood is the Apache Shiro PMC Chair and co-founder and CTO of...

6.9AI score
Exploits0
Kaspersky
Kaspersky
added 2012/01/24 12:0 a.m.58 views

KLA10394 Multiple vulnerabilities in Siemens

Multiple critical vulnerabilities have been found in Siemens products. Malicious users can exploit these vulnerabilities to read & modify arbitrary files, cause denial of service, execute arbitrary code, bypass authentication, obtain access and inject arbitrary HTTP headers. Below is a complete...

10CVSS8.4AI score0.14013EPSS
Exploits0References5
Rows per page