Lucene search
+L

4392 matches found

OSV
OSV
added 2019/10/17 7:15 p.m.9 views

CVE-2019-12611

An issue was discovered in Bitdefender BOX firmware versions before 2.1.37.37-34 that affects the general reliability of the product. Specially crafted packets sent to the miniupnpd implementation in result in the device allocating memory without freeing it later. This behavior can cause the...

4.4CVSS5.8AI score0.00323EPSS
SaveExploits0References1
Prion
Prion
added 2019/10/17 7:15 p.m.19 views

Information disclosure

An issue was discovered in Bitdefender BOX firmware versions before 2.1.37.37-34 that affects the general reliability of the product. Specially crafted packets sent to the miniupnpd implementation in result in the device allocating memory without freeing it later. This behavior can cause the...

4.9CVSS4.8AI score0.00323EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2019/10/17 12:00 a.m.8 views

Cisco SPA100 Remote Code Execution Vulnerability (CNVD-2019-36891)

The Cisco SPA100 Series is an analog phone adapter from Cisco that allows your standard analog phone to access Internet telephony services through an RJ-11 phone port. A remote code execution vulnerability exists in the Cisco SPA100 Series with firmware 1.4.1 SR4 and earlier. The vulnerability...

8CVSS8.5AI score0.00578EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/10/12 12:00 a.m.12 views

Cobham plc EXPLORER 710 has an unspecified vulnerability (CNVD-2019-35794)

The Cobham plc EXPLORER 710 is a portable satellite terminal from Cobham plc, UK. It provides features such as satellite communications and Internet access. A security vulnerability exists in the Cobham plc EXPLORER 710 using firmware version 1.07, which originates from the web root directory not...

5.5CVSS6.7AI score0.00361EPSS
SaveExploits0References1
OSV
OSV
added 2019/10/10 8:15 p.m.8 views

CVE-2019-9533

The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device...

9.8CVSS7.2AI score0.01507EPSS
SaveExploits0References1
NVD
NVD
added 2019/10/10 8:15 p.m.22 views

CVE-2019-9530

The web root directory of the Cobham EXPLORER 710, firmware version 1.07, has no access restrictions on downloading and reading all files. This could allow an unauthenticated, local attacker connected to the device to access and download any file found in the web root directory...

5.5CVSS5.5AI score0.00361EPSS
SaveExploits0References1
NVD
NVD
added 2019/10/10 8:15 p.m.18 views

CVE-2019-9529

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default. This could allow an unauthenticated, local attacker connected to the device to access the portal and to make any change to the device...

5.5CVSS5.6AI score0.00282EPSS
SaveExploits0References1
NVD
NVD
added 2019/10/10 8:15 p.m.14 views

CVE-2019-9531

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, allows unauthenticated access to port 5454. This could allow an unauthenticated, remote attacker to connect to this port via Telnet and execute 86 Attention AT commands, including some that provide unauthenticated,...

10CVSS9.7AI score0.02505EPSS
SaveExploits0References1
Prion
Prion
added 2019/10/10 8:15 p.m.19 views

Default credentials

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext. This could allow an unauthenticated, local attacker to intercept the password and gain access to the portal...

2.1CVSS8.3AI score0.00215EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2019/10/10 8:15 p.m.23 views

Design/Logic Flaw

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, allows unauthenticated access to port 5454. This could allow an unauthenticated, remote attacker to connect to this port via Telnet and execute 86 Attention AT commands, including some that provide unauthenticated,...

10CVSS9.6AI score0.02505EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2019/10/10 8:15 p.m.20 views

Authentication flaw

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default. This could allow an unauthenticated, local attacker connected to the device to access the portal and to make any change to the device...

4.9CVSS6.5AI score0.00282EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/10/10 8:09 p.m.26 views

CVE-2019-9532 The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext. This could allow an unauthenticated, local attacker to intercept the password and gain access to the portal...

8.3AI score0.00215EPSS
SaveExploits0References1
CVE
CVE
added 2019/10/10 8:09 p.m.103 views

CVE-2019-9531

The CVE-2019-9531 entry affects the Cobham EXPLORER 710 portable satcom terminal running firmware version 1.07. Connected sources confirm that the web application portal allows unauthenticated access to port 5454, enabling an unauthenticated remote attacker to connect via Telnet and execute 86 At...

10CVSS9.7AI score0.02505EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/10/10 8:09 p.m.26 views

CVE-2019-9529 The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default

The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default. This could allow an unauthenticated, local attacker connected to the device to access the portal and to make any change to the device...

6.6AI score0.00282EPSS
SaveExploits0References1
Exploit DB
Exploit DB
added 2019/10/10 12:00 a.m.345 views

SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery

Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny WebBox SMA Solar Device Firmware Version...

8.8CVSS7.8AI score0.03087EPSS
SaveExploits4
exploitpack
exploitpack
added 2019/10/10 12:00 a.m.123 views

SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery

SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware...

6.8CVSS0.1AI score0.03087EPSS
SaveExploits4
Packet Storm
Packet Storm
added 2019/10/10 12:00 a.m.217 views

SMA Solar Technology AG Sunny WebBox 1.6 Cross Site Request Forgery

Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny WebBox SMA Solar Device Firmware Version...

8.8AI score0.03087EPSS
SaveExploits4
zdt
zdt
added 2019/10/10 12:00 a.m.105 views

SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Vulnerability

Exploit for hardware platform in category web applications Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny...

6.8CVSS8.6AI score0.03087EPSS
SaveExploits4
OSV
OSV
added 2019/10/09 4:15 p.m.8 views

CVE-2019-13529

An attacker could send a malicious link to an authenticated operator, which may allow remote attackers to perform actions with the permissions of the user on the Sunny WebBox Firmware Version 1.6 and prior. This device uses IP addresses to maintain communication after a successful login, which...

8.8CVSS7.3AI score0.03087EPSS
SaveExploits4References2
CNVD
CNVD
added 2019/10/08 12:00 a.m.9 views

Smart Battery License Issue Vulnerability

Smart Battery A4 is a portable power supply device. An authorization issue vulnerability exists in the Smart Battery A4 using firmware version r1.7.9 and earlier. An attacker can exploit this vulnerability to obtain/reset the administrator password without authentication...

10CVSS7AI score0.01853EPSS
SaveExploits0References1
Rows per page
Query Builder