4752 matches found
Cross site scripting
We have recently released new version of AirMax AirOS firmware v6.3.0 for TI, XW and XM boards that fixes vulnerabilities found on AirMax AirOS v6.2.0 and prior TI, XW and XM boards, according to the description below:Multiple end-points with parameters vulnerable to reflected cross site scriptin...
PT-2020-5594 · D Link · Dsl-2888A
Name of the Vulnerable Software and Affected Versions: D-Link DSL-2888A versions prior to AU 2.31 V1.1.47ae55 Description: An issue was discovered that allows an unauthenticated attacker to bypass authentication and access authenticated pages and functionality. This is related to weaknesses in th...
PT-2020-5617 · D Link · D-Link Dsl-2888A
Name of the Vulnerable Software and Affected Versions: D-Link DSL-2888A versions prior to AU 2.31 V1.1.47ae55 Description: The issue is related to the execute cmd.cgi feature, which allows an authenticated user to execute Operating System commands. This feature is not reachable via the web user...
PT-2020-5616 · D Link · D-Link Dsl-2888A
Name of the Vulnerable Software and Affected Versions: D-Link DSL-2888A versions prior to AU 2.31 V1.1.47ae55 Description: The issue is related to a lack of authentication functionality, allowing an attacker to assign a static IP address that was once used by a valid user. This can potentially le...
Opto 22 SoftPAC Project Access Control Error Vulnerability
Opto 22 SoftPAC Project is an automation software suite from Opto 22 USA. The product is capable of providing industrial automation, process control, building automation, remote monitoring, data acquisition and industrial IoT. An Access Control Error vulnerability exists in Opto 22 SoftPAC Projec...
CVE-2020-12046
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files...
CVE-2020-10612
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPACAgent communicates with SoftPACMonitor over network Port 22000. However, this port is open without any restrictions. This allows an attacker with network access to control the SoftPACAgent service including updating SoftPAC firmware, starting ...
CVE-2020-10612
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPACAgent communicates with SoftPACMonitor over network Port 22000. However, this port is open without any restrictions. This allows an attacker with network access to control the SoftPACAgent service including updating SoftPAC firmware, starting ...
Open redirect
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPACAgent communicates with SoftPACMonitor over network Port 22000. However, this port is open without any restrictions. This allows an attacker with network access to control the SoftPACAgent service including updating SoftPAC firmware, starting ...
Code injection
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files...
CVE-2020-12046
Opto 22 SoftPAC Project (firmware update mechanism) vulnerability CVE-2020-12046 affects version 9.6 and earlier. Root cause: firmware update files are not verified by signatures, enabling an attacker to replace legitimate firmware files with malicious ones. Practical impact (as stated): arbitrar...
CVE-2020-12046
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files...
Emerson WirelessHART Gateway
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Emerson Equipment: Emerson WirelessHART Gateways 1410, 1420 and 1552WU Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could disable the...
Opto 22 SoftPAC Project
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Opto 22 Equipment: SoftPAC Project Vulnerabilities: External Control of File Name or Path, Improper Verification of Cryptographic Signature, Improper Access Control, Uncontrolled Search Path...
CVE-2020-10019
USB DFU has a potential buffer overflow where the requested length wLength is not checked against the buffer size. This could be used by a malicious USB host to exploit the buffer overflow. See NCC-ZEP-002 This issue affects: zephyrproject-rtos zephyr version 1.14.1 and later versions. version...
TP-LINK Cloud Cameras NCXXX SetEncryptKey Command Injection
Vulnerability title: TP-LINK Cloud Cameras NCXXX SetEncryptKey Command Injection Author: Pietro Oliva CVE: CVE-2020-12111 Vendor: TP-LINK Product: NC260, NC450 Affected version: NC260 %s/%08X" 0x00491734 lw a1, EncryptKeyparam ; Attacker controlled string 0x00491738 lw a2, -0x7fd4gp 0x0049173c no...
Multiple SHARP Android devices vulnerable to information disclosure
Overview Multiple SHARP Android devices contain an information disclosure vulnerability CWE-200. Impact Sensitive information of the device may be obtained by the other android application installed in the device. Solution Update the Firmware Update the firmware to the latest version according to...
JVN#93064451: Multiple SHARP Android devices vulnerable to information disclosure
Multiple SHARP Android devices contain an information disclosure vulnerability CWE-200. Impact Sensitive information of the device may be obtained by the other android application installed in the device. Solution Update the Firmware Update the firmware to the latest version according to the...
CVE-2019-20731
CVE-2019-20731 affects a broad set of NETGEAR routers and extenders (e.g., D6220, D6400, D7000v2, D8500, EX3700/3800/6000/6100/6120/6130/6150v1/6200/7000, R6250/6300v2/6400v2/6700/6900/7000/6900P/7000P/7100LG/7300DST/8000/7900P/8000P/8300/8500, WN2500RPv2, WNDR3400v3) prior to the fixed versions ...
PT-2020-6990 · Draytek · Draytek Vigor2960 +2
Name of the Vulnerable Software and Affected Versions: DrayTek Vigor3900, Vigor2960, and Vigor300B devices versions prior to 1.5.1 Description: The issue exists due to the lack of measures to neutralize special elements used in the operating system command. This allows a remote attacker to execut...