Lucene search
+L

8 matches found

NVD
NVD
•added 2026/10/08 5:17 a.m.•20 views

CVE-2026-87662

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control...

7CVSS0.00253EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/10/08 4:02 a.m.•15 views

EUVD-2026-94745

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control...

7CVSS6.3AI score0.00253EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/10/08 4:02 a.m.•47 views

CVE-2026-87662

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control...

7CVSS0.00253EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/10/08 4:02 a.m.•8 views

CVE-2026-87662

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control...

7CVSS6.3AI score0.00253EPSS
SaveExploits0References1
CVE
CVE
•added 2026/10/08 4:02 a.m.•30 views

CVE-2026-87662

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 are vulnerable to OS Command Injection (CWE-78) within the firmware download and upgrade component. The root cause is the use of unsanitized parameter strings during upgrade request processing; specifically, control characters and ...

7CVSS6.3AI score0.00253EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/10/08 12:00 a.m.•8 views

CVE-2026-87662: Improper Neutralization of Special Elements used in an OS Command

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control...

7CVSS6.3AI score0.00253EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/10/08 12:00 a.m.•11 views

PT-2026-107811

Name of the Vulnerable Software and Affected Versions Brocade Fabric versions prior to 9.2.2d Brocade Fabric versions 10.0.0 through 10.0.0a1 Description Improper handling of specific download protocols allows for the use of unsanitized parameter strings. During the processing of upgrade requests...

7CVSS6.3AI score0.00253EPSS
SaveExploits0References5
Broadcom
Broadcom
•added 2026/10/06 12:00 a.m.•19 views

An input validation and command injection vulnerability exists in the firmware download and upgrade component of Brocade Fabric OS

: Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control...

7CVSS6.3AI score0.00253EPSS
SaveExploits0
Rows per page
Query Builder