Lucene search
+L

8 matches found

Positive Technologies
Positive Technologies
•added 2022/03/30 12:00 a.m.•3 views

PT-2022-12039

Name of the Vulnerable Software and Affected Versions Firmware Analysis and Comparison Tool version 3.2 Description The issue allows an attacker with administrator privileges to perform stored XSS attacks by inserting JavaScript and HTML code in the user creation functionality. Recommendations Fo...

4.8CVSS5.7AI score0.0057EPSS
SaveExploits1References4
Positive Technologies
Positive Technologies
•added 2022/03/30 12:00 a.m.•3 views

PT-2022-12040

Name of the Vulnerable Software and Affected Versions Firmware Analysis and Comparison Tool version 3.2 Description An issue allows logged in administrators to be targeted by a CSRF attack through visiting a crafted web page. Recommendations For Firmware Analysis and Comparison Tool version 3.2,...

8.8CVSS5.7AI score0.00433EPSS
SaveExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/03/30 12:00 a.m.•5 views

CVE-2021-44312: Cross-Site Request Forgery (CSRF)

An issue was discovered in Firmware Analysis and Comparison Tool v3.2. Logged in administrators could be targeted by a CSRF attack through visiting a crafted web page...

8.8CVSS7.8AI score0.00433EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/03/30 12:00 a.m.•7 views

CVE-2021-44310: Improper Neutralization of Input During Web Page Generation

An issue was discovered in Firmware Analysis and Comparison Tool v3.2. With administrator privileges, the attacker could perform stored XSS attacks by inserting JavaScript and HTML code in user creation functionality...

4.8CVSS5.5AI score0.0057EPSS
SaveExploits1References2
CVE
CVE
•added 2020/04/02 10:43 p.m.•63 views

CVE-2020-11499

FACT 3 from Firmware Analysis and Comparison Tool shows a Stored XSS vulnerability when updating analysis details via a localhost web request, caused by mishandling of the tags and version fields in helperFunctions/mongo_task_conversion.py. This is corroborated by multiple CVE references (NVD, Re...

6.1CVSS5.9AI score0.00614EPSS
SaveExploits1References2Affected Software1
Mend
Mend
•added 2020/04/02 10:43 p.m.•4 views

CVE-2020-11499

Firmware Analysis and Comparison Tool FACT 3 has Stored XSS when updating analysis details via a localhost web request, as demonstrated by mishandling of the tags and version fields in helperFunctions/mongotaskconversion.py...

6.1CVSS0.00614EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/02 12:00 a.m.•9 views

CVE-2020-11499: Improper Neutralization of Input During Web Page Generation

Firmware Analysis and Comparison Tool FACT 3 has Stored XSS when updating analysis details via a localhost web request, as demonstrated by mishandling of the tags and version fields in helperFunctions/mongotaskconversion.py...

6.1CVSS5.6AI score0.00614EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2020/04/02 12:00 a.m.•5 views

PT-2020-12649

Name of the Vulnerable Software and Affected Versions Firmware Analysis and Comparison Tool FACT version 3 Description The issue is related to Stored XSS when updating analysis details via a localhost web request. This is caused by the mishandling of the tags and version fields in the...

6.1CVSS0.00614EPSS
SaveExploits1References5
Rows per page
Query Builder