CVE-2025-66051
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...
CVE-2025-66052
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...
CVE-2025-66049
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
CVE-2025-66049
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
CVE-2025-66051
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...
CVE-2025-66051
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...
CVE-2025-66052 Command injection in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...
CVE-2025-66051 Path traversal in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...
CVE-2025-66051
CVE-2025-66051 affects the Vivotek IP7137 camera running firmware 0200a. A path traversal flaw allows an authenticated attacker to access resources outside the webroot via a direct HTTP request. The issue is linked to end-of-life status of the product and there is no expected fix. The vulnerabili...
CVE-2025-66050 No password set for administrative account in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...
CVE-2025-66049
Affected product: Vivotek IP7137 camera with firmware 0200a. Vulnerabilities: (1) information disclosure via RTSP on port 8554 without authentication, exposing live feed; (2) command injection via /cgi-bin/admin/setparam.cgi with parameter system_ntpIt, exploitable by an admin user; (3) path trav...
CVE-2025-66049 Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
PT-2026-1854
Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to firmware version 0200a Description The Vivotek IP7137 camera, with firmware version 0200a, does not require a password by default when logging in as an administrator. Although setting a password is...
PT-2026-1855
Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to firmware version 0200a Description The Vivotek IP7137 camera is susceptible to a path traversal issue. An authenticated attacker can potentially access resources outside the intended webroot directory by...