Lucene search
+L

97 matches found

EUVD
EUVD
•added 2025/10/03 8:07 p.m.•13 views

EUVD-2022-48514

Malicious code in bioql PyPI...

7.5CVSS7.6AI score0.00854EPSS
SaveExploits1References1
BDU FSTEC
BDU FSTEC
•added 2025/09/18 12:00 a.m.•13 views

The vulnerability of the formSetFirewallCfg() function in the Tenda AC6 router’s microprogramming software allows a hacker to trigger a service failure.

The vulnerability of the formSetFirewallCfg function in the Tenda AC6 router’s microprogramming software is related to the operation of writing data outside the buffer in memory when processing the firewallEn parameter. Exploiting this vulnerability can allow a remote attacker to cause a service...

7.8CVSS6AI score0.00447EPSS
SaveExploits1References2Affected Software1
OSV
OSV
•added 2025/08/10 2:15 p.m.•13 views

CVE-2025-8810

A vulnerability classified as critical was found in Tenda AC20 16.03.08.05. Affected by this vulnerability is the function strcpy of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit...

8.7CVSS6.5AI score0.01061EPSS
SaveExploits1References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/08/10 12:00 a.m.•3 views

CVE-2025-8810: Stack-based Buffer Overflow

A vulnerability classified as critical was found in Tenda AC20 16.03.08.05. Affected by this vulnerability is the function strcpy of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit...

9CVSS6.2AI score0.01061EPSS
SaveExploits1References1
OSV
OSV
•added 2025/07/03 2:15 p.m.•14 views

CVE-2025-50260

Tenda AC6 v15.03.05.16multi is vulnerable to Buffer Overflow in the formSetFirewallCfg function via the firewallEn parameter...

7.5CVSS5.8AI score0.00447EPSS
SaveExploits1References1
NVD
NVD
•added 2025/07/03 2:15 p.m.•18 views

CVE-2025-50260

Tenda AC6 v15.03.05.16multi is vulnerable to Buffer Overflow in the formSetFirewallCfg function via the firewallEn parameter...

7.5CVSS0.00447EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2025/07/03 12:00 a.m.•25 views

CVE-2025-50260

Tenda AC6 v15.03.05.16multi is vulnerable to Buffer Overflow in the formSetFirewallCfg function via the firewallEn parameter...

0.00447EPSS
SaveExploits1References1
CVE
CVE
•added 2025/07/03 12:00 a.m.•50 views

CVE-2025-50260

The Tenda AC6 dual-band wireless router, specifically version 15.03.05.16_multi , is vulnerable to a Stack-based Buffer Overflow (CWE-121) within the formSetFirewallCfg function. The root cause is a failure to correctly validate the length and size of input data provided via the firewallEn parame...

7.5CVSS7.1AI score0.00447EPSS
SaveExploits1References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/07/03 12:00 a.m.•1 views

CVE-2025-50260: Stack-based Buffer Overflow

Tenda AC6 v15.03.05.16multi is vulnerable to Buffer Overflow in the formSetFirewallCfg function via the firewallEn parameter...

7.5CVSS5.9AI score0.00447EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/05/23 3:53 a.m.•25 views

CVE-2023-33673

Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function...

9.8CVSS7.8AI score0.01056EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/05/22 11:58 p.m.•17 views

CVE-2022-24142

Tenda AX3 v16.03.12.10CN was discovered to contain a stack overflow in the function formSetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service DoS via the firewallEn parameter...

7.8CVSS7.6AI score0.01175EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/13 12:00 a.m.•3 views

CVE-2025-29358: Buffer Copy without Checking Size of Input

Tenda RX3 USRX3V1.0brV16.03.13.11multiTDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted packet...

7.5CVSS6AI score0.00811EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/03 12:00 a.m.•2 views

CVE-2025-1851: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack...

9CVSS8.2AI score0.01092EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/03/03 12:00 a.m.•20 views

Tenda AC7 安全漏洞

The Tenda AC7 is a wireless router manufactured by Tenda. A stack overflow vulnerability exists in the formSetFirewallCfg function of the /goform/SetFirewallCfg file in Tenda AC7 15.03.06.44 and earlier versions when handling the firewallEn parameter, which stems from the program failing to check...

9CVSS9.1AI score0.01092EPSS
SaveExploits0References6
BDU FSTEC
BDU FSTEC
•added 2025/02/25 12:00 a.m.•16 views

The vulnerability of the Tenda AX3 Wi-Fi router’s microprogramming software, related to the execution of operations beyond the buffer in memory, allows attackers to escalate their privileges and cause service interruptions.

The vulnerability of the Tenda AX3 Wi-Fi router’s microprogramming software is related to the operation of the function that outputs data beyond the buffer in memory when processing the firewallEn parameter. Exploiting this vulnerability can allow a remote attacker to increase their privileges an...

9CVSS7.9AI score0.00901EPSS
SaveExploits1References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2025/02/13 12:00 a.m.•32 views

The vulnerability of the formSetFirewallCfg function in the microprogramming software for Tenda AC18 allows a hacker to trigger a service failure.

The vulnerability of the formSetFirewallCfg function in the Tenda AC18 router microprogramming system is related to buffer overflow during the processing of the firewallEn parameter. Exploiting this vulnerability can allow a remote attacker to cause a service failure...

10CVSS8.4AI score0.00752EPSS
SaveExploits1References3Affected Software1
OSV
OSV
•added 2025/01/16 9:15 p.m.•12 views

CVE-2024-57581

Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function...

9.8CVSS5.9AI score0.00752EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2025/01/16 12:00 a.m.•40 views

CVE-2024-57581

Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function...

0.00752EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/16 12:00 a.m.•5 views

CVE-2024-57581: Out-of-bounds Write

Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function...

9.8CVSS5.9AI score0.00752EPSS
SaveExploits1References1
BDU FSTEC
BDU FSTEC
•added 2024/03/27 12:00 a.m.•16 views

The vulnerability of the formSetFirewallCfg() function (/goform/SetFirewallCfg) in the Tenda AC15 router software allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the formSetFirewallCfg function /goform/SetFirewallCfg of the Tenda AC15 router’s software lies in the issue of the operation exceeding the buffer boundaries in memory when processing the firewallEn parameter. Exploiting this vulnerability allows an attacker to compromise the...

10CVSS8.1AI score0.01918EPSS
SaveExploits1References3Affected Software1
Rows per page
Query Builder