Lucene search
+L

51 matches found

Cvelist
Cvelist
added 2022/07/26 9:28 p.m.32 views

CVE-2022-31205

In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication...

8.2AI score0.0063EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/07/26 9:28 p.m.30 views

CVE-2022-31204

Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations such as project/logic uploads and downloads. This...

8.3AI score0.00619EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/06/28 12:00 a.m.8 views

Omron SYSMAC CS/CJ/CP Series 和 NJ/NX Series 安全漏洞

Omron SYSMAC CS/CJ/CP Series and Omron SYSMAC NJ/NX Series are products of Omron Corporation, Japan.Omron SYSMAC CS/CJ/CP Series is a series of programmable controllers.Omron SYSMAC NJ/NX Series is a series of machine automation controllers. Omron SYSMAC NJ/NX Series is a series of machine...

7.5CVSS7.3AI score0.0063EPSS
SaveExploits0References6
BDU FSTEC
BDU FSTEC
added 2022/06/27 12:00 a.m.12 views

The vulnerability of the Omron FINS protocol’s microprogramming software for programmable logic controllers of the SYSMAC CP series allows a intruder to gain unauthorized access to protected information.

The vulnerability of the Omron FINS protocol implemented by the microprogramming software for programmable logic controllers of the SYSMAC series lies in the deficiencies of the authentication process. Exploiting this vulnerability could allow an attacker, operating remotely, to gain unauthorized...

7.8CVSS5.5AI score0.0063EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2022/06/22 12:00 a.m.16 views

PT-2022-3093 · Omron · Omron Sysmac Cx

Name of the Vulnerable Software and Affected Versions: Omron SYSMAC Cx product family PLCs CS series, CJ series, and CP series through 2022-05-18 Description: The issue is related to a lack of cryptographic authentication in the Omron FINS 9600/TCP protocol used for engineering purposes, includin...

9.8CVSS9.6AI score0.00923EPSS
SaveExploits0References8
OSV
OSV
added 2019/02/26 3:29 p.m.8 views

CVE-2019-6594

On BIG-IP 11.5.1-11.6.3.2, 12.1.3.4-12.1.3.7, 13.0.0 HF1-13.1.1.1, and 14.0.0-14.0.0.2, Multi-Path TCP MPTCP does not protect against multiple zero length DATAFINs in the reassembly queue, which can lead to an infinite loop in some circumstances...

5.9CVSS6.2AI score0.01017EPSS
SaveExploits0References1
OpenVAS
OpenVAS
added 2017/11/24 12:00 a.m.46 views

Factory Interface Network Service (FINS) Detection (UDP)

UDP based detection of services supporting the Factory Interface Network Service FINS protocol. SPDX-FileCopyrightText: 2017 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...

7.1AI score
SaveExploits0References1
OpenVAS
OpenVAS
added 2017/11/20 12:00 a.m.119 views

Factory Interface Network Service (FINS) Detection (TCP)

TCP based detection of services supporting the Factory Interface Network Service FINS protocol. SPDX-FileCopyrightText: 2017 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...

7.1AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2016/10/27 12:00 a.m.37 views

OMRON FINS TCP Protocol Detection

Binary data scadaomrontcpdetect.nbin...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2016/10/27 12:00 a.m.18 views

OMRON FINS UDP Protocol Detection

Binary data scadaomronudpdetect.nbin...

7.3AI score
SaveExploits0
Nmap
Nmap
added 2015/06/01 4:12 a.m.259 views

omron-info NSE Script

This NSE script is used to send a FINS packet to a remote device. The script will send a Controller Data Read Command and once a response is received, it validates that it was a proper response to the command that was sent, and then will parse out the data. Example Usage nmap --script omron-info...

10CVSS0.1AI score0.99448EPSS
SaveExploits34
Rows per page
Query Builder