Lucene search
+L

5 matches found

CNVD
CNVD
•added 2025/10/15 12:00 a.m.•17 views

Tenda AC7 /goform/fast_setting_pppoe_set file buffer overflow vulnerability

Tenda AC7 is a wireless router from Tenda, a Chinese company. A buffer overflow vulnerability exists in Tenda AC7 version 15.03.06.44, which originates from the parameter Password in the file /goform/fastsettingpppoeset that fails to correctly validate the length and size of the input data, and c...

9CVSS8.3AI score0.00799EPSS
SaveExploits1References1
CVE
CVE
•added 2025/10/09 2:32 a.m.•41 views

CVE-2025-11527

CVE-2025-11527 concerns the Tenda AC7 router (version 15.03.06.44). A vulnerability in the file /goform/fast_setting_pppoe_set allows manipulation of the Password parameter to trigger a stack-based overflow in a function whose exact name is not disclosed in the documents. The issue is exploitable...

9CVSS8.2AI score0.00799EPSS
SaveExploits1References5Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/09 12:00 a.m.•1 views

CVE-2025-11527: Stack-based Buffer Overflow

A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fastsettingpppoeset. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been public...

9CVSS6.3AI score0.00799EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/07 12:00 a.m.•6 views

CVE-2025-11387: Stack-based Buffer Overflow

A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fastsettingpppoeset. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may ...

9CVSS6.3AI score0.00799EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/10/06 12:00 a.m.•3 views

CVE-2025-11325: Stack-based Buffer Overflow

A security flaw has been discovered in Tenda AC18 15.03.05.196318. Affected by this issue is some unknown functionality of the file /goform/fastsettingpppoeset. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out...

9CVSS6.3AI score0.00799EPSS
SaveExploits1References1
Rows per page
Query Builder