839 matches found
CVE-2025-7973 Rockwell Automation FactoryTalk® ViewPoint Privilege Escalation Vulnerability
A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling fu...
CVE-2025-9036 Rockwell Automation FactoryTalk® Action Manager v1.0.0 Runtime Vulnerability
A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection...
CVE-2025-9036 Rockwell Automation FactoryTalk® Action Manager v1.0.0 Runtime Vulnerability
A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection...
Rockwell Automation FactoryTalk Viewpoint
RISK EVALUATION Successful exploitation of this vulnerability could result in full privilege escalation. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system...
Rockwell Automation FactoryTalk Action Manager
RISK EVALUATION Successful exploitation of this vulnerability could allow a local unauthenticated attacker to listen to communications and manipulate the device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability,...
Rockwell FactoryTalk Linx
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to to create, update, and delete FTLinx drivers. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network...
Rockwell Automation FactoryTalk Linx 安全漏洞
Rockwell Automation FactoryTalk Linx is a suite of industrial communication solutions from Rockwell Automation USA. The product is primarily used to communicate between small applications and large automation systems, among others. A security vulnerability exists in Rockwell Automation FactoryTal...
PT-2025-33284 · Rockwell Automation · Factorytalk® Viewpoint
Name of the Vulnerable Software and Affected Versions: FactoryTalk ViewPoint versions 14.0 and earlier Description: A security issue exists in FactoryTalk ViewPoint due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs...
Rockwell Automation FactoryTalk Viewpoint 安全漏洞
Rockwell Automation FactoryTalk Viewpoint is a browser plug-in from Rockwell Automation, Inc. A security vulnerability exists in Rockwell Automation FactoryTalk Viewpoint version 14.0 and prior versions, which stems from a mishandled MSI fix operation that could result in elevated privileges...
PT-2025-33292
Name of the Vulnerable Software and Affected Versions: FactoryTalk Linx Network Browser affected versions not specified Description: A security issue exists within the FactoryTalk Linx Network Browser. Modifying the process.env.NODE ENV environment variable to ‘development’ disables FTSP token...
Rockwell Automation FactoryTalk Action Manager 安全漏洞
Rockwell Automation FactoryTalk Action Manager is an automation operations management software from Rockwell Automation. A security vulnerability exists in Rockwell Automation FactoryTalk Action Manager that stems from the runtime event system allowing unauthenticated connections to receive...
The vulnerability of the FactoryTalk Linx automation system’s software, related to insufficient verification of input data, allows a intruder to trigger a service failure.
The vulnerability of the FactoryTalk Linx automation system’s software is related to insufficient verification of input data. Exploiting this vulnerability can allow a malicious actor to cause service interruptions by sending a malicious package...
The vulnerability of the FactoryTalk Linx automation system’s software relates to operations where data is written beyond the buffer boundaries in memory. This allows attackers to bypass the ASLR protection mechanism and gain access to confidential information.
The vulnerability of the FactoryTalk Linx automation system’s software is related to the execution of operations outside the buffer boundaries in memory. Exploiting this vulnerability allows a malicious actor to bypass the ASLR protection mechanism and gain access to confidential information...
The vulnerability of the FactoryTalk Linx automation system’s software lies in the possibility of an operation exceeding the buffer boundaries in memory, allowing a hacker to execute arbitrary code.
The vulnerability of the FactoryTalk Linx automation system’s software is related to the execution of operations outside the buffer boundaries in memory. Exploiting this vulnerability allows a malicious actor to execute arbitrary code remotely...
The vulnerability of the Rockwell Automation FactoryTalk View SE HMI software lies in the fact that operations may escape out of the buffer into memory, allowing an attacker to execute arbitrary code.
The vulnerability of the Rockwell Automation FactoryTalk View SE human-machine interface control software lies in the execution of operations beyond the buffer boundaries in memory. Exploiting this vulnerability can allow an attacker to execute arbitrary code...
The vulnerability of the Redundancy Host Service (RdcyHost.exe) of the FactoryTalk Services Platform allows a attacker to increase their privileges and execute arbitrary code.
The vulnerability of the Redundancy Host Service RdcyHost.exe component of the FactoryTalk Services Platform is related to insufficient validation of input data. Exploiting this vulnerability can allow a malicious actor to increase their privileges and execute arbitrary code...
The vulnerability of the Rockwell Automation FactoryTalk View SE HMI software lies in the lack of authentication for critical functions. This allows attackers to bypass security restrictions and write arbitrary files.
The vulnerability of the Rockwell Automation FactoryTalk View SE human-machine interface control software is related to the lack of authentication for critical functions. Exploiting this vulnerability allows a malicious actor to bypass security restrictions and write arbitrary files...
The vulnerability of the Rockwell Automation FactoryTalk View SE HMI software, related to insufficient validation of input data, allows a perpetrator to execute arbitrary code.
The vulnerability of the Rockwell Automation FactoryTalk View SE human-machine interface control software is related to insufficient validation of input data. Exploiting this vulnerability can allow an attacker to execute arbitrary code...
The vulnerability of the FactoryTalk Services Platform, related to buffer overflows in dynamic memory, can lead to service failures.
The vulnerability of the FactoryTalk Services Platform lies in the overflow of memory buffer in dynamic memory. Exploiting this vulnerability can allow a malicious actor to cause service failures remotely...
CVE-2023-2444
A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, t...