Lucene search
K

22 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-26964

Malware in sbrugna...

7.5CVSS7.5AI score0.04219EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2011-2925

Malware in sbrugna...

6.9CVSS6.4AI score0.00004EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-28107

Malware in sbrugna...

10CVSS9.2AI score0.01521EPSS
Exploits0References2
RedhatCVE
RedhatCVE
added 2025/05/22 5:41 p.m.5 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.5CVSS6.8AI score0.04219EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 4:46 p.m.7 views

CVE-2020-6967

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data...

10CVSS6.8AI score0.01521EPSS
Exploits0References1
ICS
ICS
added 2023/05/18 12:0 p.m.23 views

Rockwell Automation FactoryTalk Diagnostics (Update B)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: FactoryTalk Diagnostics Vulnerabilities: Deserialization of Untrusted Data 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original...

10CVSS9.9AI score0.01521EPSS
Exploits0References28
OSV
OSV
added 2020/12/29 4:15 p.m.1 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.5CVSS7.2AI score
Exploits0References1
NVD
NVD
added 2020/12/29 4:15 p.m.11 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.5CVSS7.4AI score0.04219EPSS
Exploits0References1
Prion
Prion
added 2020/12/29 4:15 p.m.16 views

Code injection

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

5CVSS7.4AI score0.04219EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2020/12/29 3:18 p.m.44 views

CVE-2020-5807

Summary: CVE-2020-5807 affects Rockwell Automation’s FactoryTalk Diagnostics (and related components) where an unauthenticated remote actor can send data to RsvcHost.exe (TCP port 5241) to inject log entries. The attacker can craft long fields that trigger an unhandled wcscpy_s() exception when a...

7.5CVSS7.4AI score0.04219EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/12/29 3:18 p.m.14 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.4AI score0.04219EPSS
Exploits0References1
CNNVD
CNNVD
added 2020/12/29 12:0 a.m.1 views

FactoryTalk Diagnostics All Security Vulnerabilities

Rockwell Automation FactoryTalk Diagnostics is a Rockwell Automation software program for diagnosing the status of equipment in industrial environments. The software is a subsystem of the FactoryTalk Industrial Architecture. A security vulnerability exists in all versions of FactoryTalk...

7.5CVSS5.8AI score0.04219EPSS
Exploits0References4
NVD
NVD
added 2020/03/23 9:15 p.m.15 views

CVE-2020-6967

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data...

10CVSS9.5AI score0.01521EPSS
Exploits0References1
Prion
Prion
added 2020/03/23 9:15 p.m.15 views

Design/Logic Flaw

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data...

10CVSS9.3AI score0.01521EPSS
Exploits0References1
CNVD
CNVD
added 2020/02/21 12:0 a.m.2 views

Deserialization Vulnerability in Rockwell Automation FactoryTalk Diagnostics Untrustworthy Data

Rockwell Automation is a provider of industrial automation, control and information technology solutions. A deserialization of untrusted data vulnerability exists in Rockwell Automation FactoryTalk Diagnostics, which can be exploited by an attacker to execute arbitrary code with SYSTEM-level...

10CVSS7.7AI score0.01521EPSS
Exploits0References1
OpenVAS
OpenVAS
added 2019/01/19 12:0 a.m.75 views

Rockwell Automation FactoryTalk Diagnostics Detection (Windows SMB Login)

SMB login-based detection of Rockwell Automation FactoryTalk Diagnostics. SPDX-FileCopyrightText: 2019 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

7.1AI score
Exploits0References1
NVD
NVD
added 2011/07/28 6:55 p.m.8 views

CVE-2011-2957

Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 CPR9 SR3 allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer .ftd configuration file, which triggers memory corruption...

6.9CVSS7.1AI score0.00004EPSS
Exploits0References3
Prion
Prion
added 2011/07/28 6:55 p.m.8 views

Memory corruption

Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 CPR9 SR3 allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer .ftd configuration file, which triggers memory corruption...

6.9CVSS7.6AI score0.00004EPSS
Exploits0References3Affected Software1
ATTACKERKB
ATTACKERKB
added 2011/07/28 6:55 p.m.1 views

CVE-2011-2957

Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 CPR9 SR3 allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer .ftd configuration file, which triggers memory corruption...

6.9CVSS6.1AI score0.00004EPSS
Exploits0References4
CVE
CVE
added 2011/07/28 6:0 p.m.39 views

CVE-2011-2957

Rockwell Automation FactoryTalk Diagnostics Viewer before version 2.30.00 (CPR9 SR3) is affected by a memory‑corruption vulnerability triggered by a crafted .ftd configuration file. The issue allows local users to execute arbitrary code when the vulnerable viewer processes the crafted file; it is...

6.9CVSS7.3AI score0.00004EPSS
Exploits0References3Affected Software1
Rows per page
Query Builder