2904 matches found
The vulnerability of the OPC Factory Server data server, related to incorrect restrictions on XML links to external objects, allows attackers to gain unauthorized access to the file system.
The vulnerability of the OPC Factory Server data server is related to incorrect restrictions on XML links to external objects. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain unauthorized access to the file system...
CVE-2023-1618
Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and i...
CVE-2023-1618
The vulnerability CVE-2023-1618 affects Mitsubishi Electric MELSEC WS Series WS0-GETH00200 Ethernet interface modules (serial numbers 2310 and prior). The issue is an authentication bypass via a hidden telnet function that is enabled by default at factory, allowing remote unauthenticated access t...
CVE-2023-1618 Authentication Bypass Vulnerability in MELSEC WS Series Ethernet Interface Module
Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function and i...
Schneider Electric OPC Factory Server XML External Entity Injection Vulnerability
Schneider Electric OPC Factory Server is a software application from the French company Schneider Electric Schneider Electric. An XML external entity injection vulnerability exists in Schneider Electric OPC Factory Server, which stems from an improper restriction on XML external entity references...
Schneider Electric OPC Factory Server 代码问题漏洞
Schneider Electric OPC Factory Server is a software application from the French company Schneider Electric Schneider Electric. An XML external entity injection vulnerability exists in Schneider Electric OPC Factory Server, which stems from an improper restriction on XML external entity references...
PT-2023-2955 · Unknown · Opc Factory Server
Name of the Vulnerable Software and Affected Versions: OPC Factory Server affected versions not specified Description: The issue is related to improper restriction of XML external entity references, which could allow a remote attacker to gain unauthorized read access to the file system. This can...
Cloud Security Strategies for Manufacturing
Protecting production while supporting growing cloud initiatives The manufacturing industry is in limbo as organizations shift to cloud services. Many organizations are transitioning services to the cloud, but the vast majority maintain hybrid network environments that lean heavily on on-prem...
CISA Releases One Industrial Control Systems Advisory
CISA released one Industrial Control Systems ICS advisory on May 2, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories for technical...
Upgraded Q -> 2 from #854 [1683053410661]
Judge has assessed an item in Issue 854 as 2 risk. The relevant finding follows: L-01 Reorg attack possibility in pool factory 1 --- The text was updated successfully, but these errors were encountered: All reactions...
CVE-2023-23451
CVE-2023-23451 affects SICK Flexi Classic and Flexi Soft Gateways (e.g., UE410-EN1/EN3/EN3S04/EN4 and FX0-GENT00000/FX0-GMOD00000/FX0-GPNT00000, including V2 variants) where Telnet is enabled by factory default and no password is set in the default configuration. This creates potential unauthoriz...
Security Issues in FINS protocol
Overview FINS Factory Interface Network Service is a message communication protocol, which is designed to be used in closed FA Factory Automation networks, and is used in FA networks composed of Omron products. FINS commands enable to read/write information, conduct various operations and set the...
CVE-2023-0277
The WC Fields Factory WordPress plugin through 4.1.5 does not properly sanitise and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by high privilege users such as admin...
CVE-2023-0277
The WC Fields Factory WordPress plugin through 4.1.5 does not properly sanitise and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by high privilege users such as admin...
Sql injection
The WC Fields Factory WordPress plugin through 4.1.5 does not properly sanitise and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by high privilege users such as admin...
CVE-2023-0277
The CVE CVE-2023-0277 affects WC Fields Factory for WordPress (
CVE-2023-0277 WC Fields Factory <= 4.1.5 - ShopManager+ SQLi
The WC Fields Factory WordPress plugin through 4.1.5 does not properly sanitise and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by high privilege users such as admin...
PT-2023-21095 · Omron · Sysmac Nx1P-Series Cpu Units +4
Name of the Vulnerable Software and Affected Versions: SYSMAC CS-series CPU Units, all versions SYSMAC CJ-series CPU Units, all versions SYSMAC CP-series CPU Units, all versions SYSMAC NJ-series CPU Units, all versions SYSMAC NX1P-series CPU Units, all versions SYSMAC NX102-series CPU Units, all...
WordPress Plugin WC Fields Factory SQL注入漏洞
WordPress and WordPress plugin are both products of the WordPress Foundation.WordPress is a blogging platform developed using the PHP language. The platform supports personal blog sites on PHP and MySQL servers.WordPress plugin is an application plugin. A SQL injection vulnerability exists in...
Sielco PolyEco Digital FM Transmitter 2.0.6 - Authorization Bypass Factory Reset Vulnerability
Exploit Title: Sielco PolyEco Digital FM Transmitter 2.0.6 - Authorization Bypass Factory Reset Exploit Author: LiquidWorm Vendor: Sielco S.r.l Product web page: https://www.sielco.org Affected version: PolyEco1000 CPU:2.0.6 FPGA:10.19 PolyEco1000 CPU:1.9.4 FPGA:10.19 PolyEco1000 CPU:1.9.3...