Lucene search
+L

229 matches found

ICS
ICS
added 2023/07/12 6:00 a.m.49 views

Rockwell Automation Select Communication Modules

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: 1756-EN2T, 1756-EN2TK, 1756-EN2TXT, 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT, 1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT, 1756-EN2F, 1756-EN2FK, 1756-EN3TR, 1756-EN3TRK,...

9.8CVSS9.9AI score0.0469EPSS
SaveExploits0References8
ICS
ICS
added 2023/06/23 6:00 a.m.32 views

SpiderControl SCADAWebServer

1. EXECUTIVE SUMMARY CVSS v3 4.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: SpiderControl Equipment: SCADAWebServer Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could result in a denial-of-service condition 3. TECHNICAL DETAILS...

6.5CVSS6.7AI score0.01049EPSS
SaveExploits0References10
ICS
ICS
added 2023/05/18 6:00 a.m.41 views

Mitsubishi Electric MELSEC WS Series

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: WS0-GETH00200 Vulnerabilities: Active Debug Code 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-23-138-02...

8.6CVSS8.4AI score0.01132EPSS
SaveExploits0References8
ICS
ICS
added 2023/05/12 6:09 p.m.77 views

SDG PnPSCADA

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: SDG Technologies Equipment: PnPSCADA Vulnerabilities: SQL Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to interact with the database and retrieve...

9.8CVSS9.1AI score0.08079EPSS
SaveExploits3References5
ICS
ICS
added 2023/05/11 10:14 p.m.34 views

Rockwell Automation PanelView 800

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PanelView 800 Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow remote code...

10CVSS10AI score0.03524EPSS
SaveExploits1References5
ICS
ICS
added 2023/05/11 6:00 a.m.112 views

Teltonika Remote Management System and RUT Model Routers

1. EXECUTIVE SUMMARY CVSS v3 9.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Teltonika Equipment: Remote Management System and RUT model routers Vulnerabilities: Observable Response Discrepancy, Improper Authentication, Server-Side Request Forgery, Cross-site Scripting, Inclusio...

9.8CVSS9.5AI score0.0148EPSS
SaveExploits0References10
ICS
ICS
added 2023/05/05 6:00 a.m.76 views

Hitachi Energy's RTU500 Series Product (UPDATE B)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Hitachi Energy Equipment : RTU500 Series Vulnerabilities : Type Confusion, Observable Timing Discrepancy, Out-of-bounds Read, Infinite Loop, Classic Buffer Overflow 2. RISK EVALUATION...

9.8CVSS9.1AI score0.87816EPSS
SaveExploits3References8
ICS
ICS
added 2023/04/25 6:00 a.m.59 views

Keysight N8844A Data Analytics Web Service (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Keysight Equipment : N8844A Data Analytics Web Service Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to remote code...

9.8CVSS10AI score0.00799EPSS
SaveExploits0References10
ICS
ICS
added 2023/04/20 3:30 p.m.36 views

Omron CS/CJ Series

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Omron Equipment: SYSMAC CS/CJ Series Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access...

8.6CVSS8.6AI score0.00536EPSS
SaveExploits0References4
ICS
ICS
added 2023/04/20 3:30 p.m.36 views

INEA ME RTU

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: INEA Equipment: ME RTU Vulnerability: OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED...

10CVSS10AI score0.01663EPSS
SaveExploits0References5
ICS
ICS
added 2023/04/18 7:27 p.m.116 views

FANUC ROBOGUIDE-HandlingPRO

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Exploitable remotely Vendor: FANUC Equipment: ROBOGUIDE-HandlingPRO Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read and/or overwrite files on the system running the affected...

7.5CVSS7.3AI score0.00943EPSS
SaveExploits0References7
ICS
ICS
added 2023/03/31 4:10 p.m.83 views

Rockwell Automation Modbus TCP AOI Server

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Modbus TCP Server Add-On Instruction AOI Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this...

5.3CVSS5AI score0.00849EPSS
SaveExploits0References5
ICS
ICS
added 2023/03/23 6:00 a.m.88 views

ProPump and Controls Osprey Pump Controller (Update A)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available Vendor : ProPump and Controls, Inc. Equipment : Osprey Pump Controller Vulnerabilities: Insufficient Entropy, Use of GET Request Method with Sensitive Query Strings, Use...

9.8CVSS10AI score0.17571EPSS
SaveExploits9References10
ICS
ICS
added 2023/02/14 12:00 a.m.48 views

Siemens COMOS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

10CVSS9.8AI score0.00813EPSS
SaveExploits0References11
ICS
ICS
added 2023/02/02 12:00 p.m.52 views

Mitsubishi Electric Multiple Factory Automation Products (Update D)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: GOT2000 compatible HMI software, CC-Link IE TSN Industrial Managed Switch, MELSEC iQ-R Series OPC UA Server Module Vulnerabilities: Infinite Loop, OS Command Injection 2...

10CVSS10AI score0.82612EPSS
SaveExploits7References29
ICS
ICS
added 2022/12/15 12:00 a.m.51 views

Siemens APOGEE/TALON Field Panels

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: APOGEE PXC/TALON TC Vulnerabilities: Predictable Exact Value from Previous Values 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to hijack...

6.5CVSS6.8AI score0.0135EPSS
SaveExploits0References8
ICS
ICS
added 2022/12/13 12:00 a.m.64 views

Siemens SCALANCE SC-600 Family

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE SC-600 Family Vulnerability: Out-of-bounds Write, Use After Free, Allocation of Resources Without Limits or Throttling 2. RISK EVALUATION Successful exploitation of this...

7.8CVSS8.9AI score0.3216EPSS
SaveExploits3References11
ICS
ICS
added 2022/12/13 12:00 a.m.59 views

Siemens SCALANCE Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

9.8CVSS7.4AI score0.0221EPSS
SaveExploits0References10
ICS
ICS
added 2022/12/13 12:00 a.m.59 views

Schneider Electric APC Easy UPS Online

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: APC Easy UPS Online Vulnerabilities: Missing Authentication for Critical Function, Unrestricted Upload of File with Dangerous Type, Incorrect Permission Assignment for...

9.8CVSS9.9AI score0.01071EPSS
SaveExploits0References4
ICS
ICS
added 2022/12/13 12:00 a.m.71 views

Siemens Mendix Email Connector

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix Email Connector Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated remote attacker to read and...

8.1CVSS8.3AI score0.00705EPSS
SaveExploits0References11
Rows per page
Query Builder