90 matches found
CVE-2024-2892
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The explo...
EUVD-2009-4006
Malware in sbrugna...
EUVD-2021-25017
Malware in sbrugna...
EUVD-2024-48684
Malicious code in bioql PyPI...
EUVD-2024-16777
Malicious code in bioql PyPI...
EUVD-2025-21096
Malicious code in bioql PyPI...
EUVD-2023-40448
Malicious code in bioql PyPI...
EUVD-2024-27930
Malicious code in bioql PyPI...
EUVD-2022-35563
Malicious code in bioql PyPI...
EUVD-2025-17365
Malicious code in bioql PyPI...
CVE-2025-9250
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This impacts the function setPWDbyBBS of the file /goform/setPWDbyBBS. Such manipulation of the argument hint leads to stack-based buffer overflow. ...
CVE-2025-7532 Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
A vulnerability has been found in Tenda FH1202 1.2.0.14408 and classified as critical. This vulnerability affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated...
PT-2025-28023 · Hdf5 +1 · Hdf5 +1
Name of the Vulnerable Software and Affected Versions: HDF5 version 1.14.6 Description: A problematic vulnerability was found in HDF5, affecting the function H5FS sect link size of the file src/H5FSsection.c. This manipulation leads to a heap-based buffer overflow. The attack can be launched on t...
CVE-2025-6374
D-Link DIR-619L (firmware 2.06B01) contains a stack-based buffer overflow in the formSetACLFilter function (/goform/formSetACLFilter) caused by unsafely handling the curTime argument. This remote vulnerability could allow an attacker to exploit the overflow and potentially take control or crash t...
CVE-2025-6121
A vulnerability, which was classified as critical, has been found in D-Link DIR-632 FW103B08. Affected by this issue is the function getpurecontent of the component HTTP POST Request Handler. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be...
CVE-2025-5978
A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has...
CVE-2025-5862
CVE-2025-5862 affects Tenda AC7 (firmware version 15.03.06.44). The vulnerability is in the formSetPPTPUserList function of /goform/setPptpUserList, where manipulation of the list argument leads to a buffer overflow. This can potentially be exploited remotely; multiple sources note public exploit...
CVE-2025-5852 Tenda AC6 setPptpUserList formSetPPTPUserList buffer overflow
A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been...
CVE-2025-5790
A vulnerability classified as critical was found in TOTOLINK X15 1.0.0-B20230714.1105. This vulnerability affects unknown code of the file /boafrm/formIpQoS of the component HTTP POST Request Handler. The manipulation of the argument mac leads to buffer overflow. The attack can be initiated...
PT-2025-24312 · Totolink · Totolink X15
Name of the Vulnerable Software and Affected Versions: TOTOLINK X15 version 1.0.0-B20230714.1105 Description: A critical issue has been identified, affecting an unknown function of the file /boafrm/formDMZ of the component HTTP POST Request Handler. The manipulation of the submit-url argument lea...