Lucene search
+L

1515 matches found

Cvelist
Cvelist
added 2022/02/09 12:0 a.m.33 views

CVE-2022-22807

A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert former...

7.6AI score0.00938EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.7 views

EcoStruxure Geo SCADA Expert 代码问题漏洞

EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable surveillance and data acquisition SCADA software A code issue vulnerability exists in EcoStruxure Geo SCADA Expert that stems from a denial of service to the Geo SCADA server when an improper HTTP request is received...

7.5CVSS7.5AI score0.00999EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2022/02/08 12:0 a.m.7 views

PT-2022-6694 · Schneider Electric · Ecostruxure Ev Charging Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure EV Charging Expert versions prior to V4.0.0.13 Description: A vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within...

8.5CVSS7.2AI score0.00938EPSS
SaveExploits0References7
Securelist
Securelist
added 2022/02/07 10:0 a.m.14 views

Roaming Mantis reaches Europe

Roaming Mantis is a malicious campaign that targets Android devices and spreads mobile malware via smishing. We have been tracking Roaming Mantis since 2018, and published five blog posts about this campaign: Roaming Mantis uses DNS hijacking to infect Android smartphones Roaming Mantis dabbles i...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.23 views

Schneider Electric Modicon NULL Pointer Dereference (CVE-2021-22792)

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BMEP and BMEH, all versions, Modicon M340 CPU par...

7.5CVSS7.6AI score0.00937EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.21 views

Schneider Electric Web Server on Modicon M340 Out-of-Bounds Read (CVE-2020-7562)

A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...

8.1CVSS8.1AI score0.00891EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.31 views

Schneider Electric Modicon Out-of-bounds Read (CVE-2021-22790)

A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BMEP and BMEH, all versions, Modicon M340 CPU part...

6.5CVSS7.1AI score0.00839EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.15 views

Schneider Electric Web Server on Modicon M340 Out-of-Bounds Write (CVE-2020-7563)

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause corruption of data, a crash, or code execution when uploading a specially crafted...

8.8CVSS8.3AI score0.01082EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.19 views

Schneider Electric Modicon Injection (CVE-2020-7475)

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...

9.8CVSS8.5AI score0.01542EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.830 views

Schneider Electric Modicon Controllers and Software Authentication Bypass By Spoofing (CVE-2021-22779)

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, SCADAPack...

9.1CVSS8.7AI score0.01023EPSS
SaveExploits0References3
NVD
NVD
added 2022/02/04 11:15 p.m.23 views

CVE-2022-22804

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected...

5.4CVSS0.00451EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/04 11:15 p.m.29 views

CVE-2022-22727

A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power...

9.3CVSS0.01235EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/04 11:15 p.m.4 views

CVE-2022-22804

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected...

5.4CVSS5.8AI score0.00451EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/02/04 11:15 p.m.7 views

CVE-2022-22726

A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert Versions 2020 and prior...

6.5CVSS6.7AI score0.00771EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2022/02/04 11:15 p.m.8 views

CVE-2022-22804

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected...

5.4CVSS6.1AI score0.00451EPSS
SaveExploits0References2
NVD
NVD
added 2022/02/04 11:15 p.m.19 views

CVE-2022-22726

A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert Versions 2020 and prior...

6.5CVSS0.00771EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/04 11:15 p.m.4 views

CVE-2022-22727

A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power...

8.8CVSS7.3AI score
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/02/04 11:15 p.m.6 views

CVE-2022-22727

A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power...

9.3CVSS7.3AI score0.01235EPSS
SaveExploits0References2
OSV
OSV
added 2022/02/04 11:15 p.m.5 views

CVE-2022-22726

A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert Versions 2020 and prior...

6.5CVSS5.9AI score0.00771EPSS
SaveExploits0References1
Prion
Prion
added 2022/02/04 11:15 p.m.17 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected...

3.5CVSS5.4AI score0.00451EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder