1538 matches found
CVE-2022-32748
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise...
Schneider Electric StruxureWare Data Center Expert 安全漏洞
Schneider Electric StruxureWare Data Center Expert StruxureWare Data Center Management Expert is a monitoring software from the French company Schneider Electric Schneider Electric. Suitable for a variety of organizations to monitor their company-wide power, cooling, security, environment. A...
The vulnerability of SCADA systems such as EcoStruxure Geo SCADA Expert 2020 and EcoStruxure Geo SCADA Expert 2019 lies in the lack of protection for operational data, allowing attackers to disclose sensitive information.
The vulnerability of SCADA systems such as EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2019, and EcoStruxure Geo SCADA Expert 2021 lies in the lack of protection for operational data. Exploiting this vulnerability can allow a malicious actor, operating remotely, to disclose th...
CVE-2022-32520
The CVE-2022-32520 entry affects Schneider Electric Data Center Expert before version 7.9.0. It describes a CWE-522 vulnerability (insufficiently protected credentials) that could allow a malicious remote actor to gain unauthorized access to a DCE instance over a network. The connected sources co...
CVE-2022-32748
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise...
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
Schneider Electric StruxureWare Data Center Expert 安全漏洞
Schneider Electric StruxureWare Data Center Expert StruxureWare Data Center Management Expert is a monitoring software from the French company Schneider Electric Schneider Electric. Suitable for a variety of organizations to monitor their company-wide power, cooling, security, environment. A...
CVE-2022-32520
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32519
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32521
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32519
CVE-2022-32519 affects Schneider Electric StruxureWare Data Center Expert prior to V7.9.0. The root cause is storing passwords in a recoverable format, which could allow a malicious third party to gain unauthorized, potentially full control over a DCE instance when accessed over a network. Affect...
CVE-2022-45788
Schneider Electric’s CVE-2022-45788 affects EcoStruxure Control Expert, EcoStruxure Process Expert, and multiple Modicon CPU families (M340 BMXP34*, M580 BMEP*/BMEH*, M580 Safety BMEP58*/BMEH58*, Momentum Unity 171CBU*, MC80 BMKC80, Legacy Quantum 140CPU65* and Premium TSXP57*; all versions prior...
Schneider Electric StruxureWare Data Center Expert 代码问题漏洞
Schneider Electric StruxureWare Data Center Expert StruxureWare Data Center Management Expert is a monitoring software from the French company Schneider Electric Schneider Electric. Suitable for a variety of organizations to monitor their company-wide power, cooling, security, environment. A code...
CVE-2022-32518
CVE-2022-32518 affects Schneider Electric Data Center Expert prior to version 7.9.0. It is a CWE-522 Insufficiently Protected Credentials flaw that could allow unauthorized access to a DCE instance over a network by a malicious third party. The vulnerability impact is described as high/critical i...
expert-marketplace.de Cross Site Scripting vulnerability OBB-3169022
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
Phoenix Contact PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...
PT-2023-1019 · Schneider Electric · Ecostruxure Geo Scada Expert +1
Name of the Vulnerable Software and Affected Versions: EcoStruxure Geo SCADA Expert versions 2019 through 2021 prior to October 2022 ClearSCADA versions prior to the fixed version Description: A vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific...
Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU (Update A)
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: EcoStruxure Control Expert, EcoStruxure Process Expert, Modicon M340 CPU, Modicon M580 CPU, Modicon Momentum Unity M1E Processor, Modicon MC80 Vulnerability: Authentication Bypass by...
PT-2023-1079 · Schneider Electric · Modicon M580 Cpu +7
Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert All Versions EcoStruxure Process Expert All Versions Modicon M340 CPU - part numbers BMXP34 All Versions Modicon M580 CPU - part numbers BMEP and BMEH All Versions Modicon M580 CPU Safety - part numbers BMEP58S and...
PT-2023-1235 · Schneider Electric · Ecostruxure Geo Scada Expert +1
Name of the Vulnerable Software and Affected Versions: EcoStruxure Geo SCADA Expert versions 2019 through 2021 ClearSCADA all versions Description: A vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. This...