1515 matches found
Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU Authentication Bypass By Capture-Replay (CVE-2022-45789)
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert Versions pri...
The vulnerability of the monitoring system for critical equipment, StruxureWare Data Center Expert, is related to deficiencies in the authentication process, allowing a perpetrator to execute arbitrary codes.
The vulnerability of the StruxureWare Data Center Expert monitoring system is related to deficiencies in authentication procedures. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code remotely...
What are the biggest cyberthreats heading our way in 2023?
Wiz and Procter & Gamble experts share their security insights and tips...
Schneider Electric Modicon M221 Programmable Logic Controller Inadequate Encryption Strength (CVE-2020-7565)
A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. This plugin on...
Wago PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
Input validation
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
The vulnerability of the monitoring system for critical equipment, StruxureWare Data Center Expert, arises due to the lack of measures taken to protect the structure of the web page. This vulnerability allows attackers to carry out XSS attacks.
The vulnerability of the StruxureWare Data Center Expert monitoring system exists due to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a malicious actor to carry out XSS attacks...
The vulnerability of the monitoring system for critical equipment, StruxureWare Data Center Expert, arises due to the failure to take measures to neutralize special elements used in the operating system’s command set. This allows a perpetrator to execute arbitrary commands.
The vulnerability of the StruxureWare Data Center Expert monitoring system exists because measures to neutralize special elements used in the operating system have not been taken. Exploiting this vulnerability allows a malicious actor to execute arbitrary commands via the SSH protocol remotely...
PT-2023-1789 · Schneider Electric · Struxureware Data Center Expert
Name of the Vulnerable Software and Affected Versions: StruxureWare Data Center Expert versions prior to 7.9.2 Description: The issue is related to insufficient authorization procedures in the system, allowing a remote attacker to perform unauthorized functions, modify, or delete arbitrary conten...
PT-2023-3274 · Schneider Electric · Struxureware Data Center Expert
Name of the Vulnerable Software and Affected Versions: StruxureWare Data Center Expert versions prior to 7.9.2 Description: The issue is related to insufficient protection of the web page structure, allowing a remote attacker to conduct a cross-site scripting attack in the DCE file upload endpoin...
PT-2023-1607 · Schneider Electric · Struxureware Data Center Expert
Name of the Vulnerable Software and Affected Versions: StruxureWare Data Center Expert versions prior to 7.9.2 Description: The issue is related to insufficient authorization procedures in the system, allowing a remote attacker to potentially execute arbitrary code. Specifically, it involves a...
PT-2023-3272 · Schneider Electric · Struxureware Data Center Expert
Name of the Vulnerable Software and Affected Versions: StruxureWare Data Center Expert versions prior to 7.9.2 Description: The issue is related to improper control of code generation, allowing remote code execution via the hostname parameter when maliciously crafted hostname syntax is entered...
PT-2023-1418 · Schneider Electric · Struxureware Data Center Expert
Name of the Vulnerable Software and Affected Versions: StruxureWare Data Center Expert versions prior to 7.9.2 Description: A vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. The issue is related to...
The vulnerability of the SoMachine and EcoStruxure Machine Expert programming devices lies in the lack of protection for operational data, which allows attackers to disclose the protected information.
The vulnerability of the SoMachine and EcoStruxure Machine Expert logic controller programs lies in the lack of protection for operational data. Exploiting this vulnerability allows a malicious actor to disclose sensitive information by sending certain messages to the server’s TCP port through th...
CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
Information disclosure
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...