Lucene search
+L

1538 matches found

Zero Day Initiative
Zero Day Initiative
added 2025/08/12 12:00 a.m.21 views

(0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetTgmlContent Directory Traversal Information Disclosure Vulnerability

This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The specific flaw exists within the GetTgmlContent method. The issue results...

4.9CVSS6.4AI score0.00908EPSS
SaveExploits0References2
Packet Storm News
Packet Storm News
added 2025/08/04 12:00 a.m.15 views

PentestJudge: Judging Agent Behavior against Operational Requirements

We introduce PentestJudge, a system for evaluating the operations of penetration testing agents. PentestJudge is a large language model LLM-as-judge with access to tools that allow it to consume arbitrary trajectories of agent states and tool call history to determine whether a security agent's...

6.7AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2025/07/29 12:00 a.m.6 views

EcoStruxure IT Data Center Expert <= 8.3 Multiple Vulnerabilities (SEVD-2025-189-01)

The version of EcoStruxure IT Data Center Expert installed on the remote host is prior to 9.0. It is, therefore, affected by multiple vulnerabilities as referenced in the apsb25-36 advisory. - A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection'...

9.5CVSS6.5AI score0.1929EPSS
SaveExploits6References7
CNVD
CNVD
added 2025/07/25 12:00 a.m.16 views

Schneider Electric EcoStruxure IT Data Center Expert Server-Side Request Forgery Vulnerability

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A server-side request forgery vulnerability exists in Schneider...

6.3CVSS6.8AI score0.00486EPSS
SaveExploits2References1
Packet Storm News
Packet Storm News
added 2025/07/22 12:00 a.m.16 views

GATEBLEED: Exploiting On-Core Accelerator Power Gating for High Performance and Stealthy Attacks on AI

As power consumption from AI training and inference continues to increase, AI accelerators are being integrated directly into the CPU. Intel's Advanced Matrix Extensions AMX is one such example, debuting on the 4th generation Intel Xeon Scalable CPU. We discover a timing side and covert channel,...

6.7AI score
SaveExploits0
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.18 views

Schneider Electric EcoStruxure IT Data Center Expert 操作系统命令注入漏洞

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. Schneider Electric EcoStruxure IT Data Center Expert suffers from...

9.5CVSS8.1AI score0.1929EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.14 views

Schneider Electric EcoStruxure IT Data Center Expert 代码注入漏洞

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A code injection vulnerability exists in Schneider Electric...

7.2CVSS7.2AI score0.00341EPSS
SaveExploits2References1
BDU FSTEC
BDU FSTEC
added 2025/07/11 12:00 a.m.20 views

The vulnerability of the web interface of the software for managing the infrastructure of the EcoStruxure IT Data Center Expert allows a perpetrator to execute arbitrary code.

The vulnerability of the web interface of the software for managing the infrastructure of the EcoStruxure IT Data Center Expert is related to the failure to take measures to neutralize specific elements. Exploiting this vulnerability allows a malicious actor to execute arbitrary code by creating ...

10CVSS6AI score0.1929EPSS
SaveExploits1References2Affected Software1
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.11 views

Schneider Electric EcoStruxure Power Monitoring Expert和Schneider Electric EcoStruxure Power Operation 安全漏洞

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation Schneider Electric EPO are both products of the French company Schneider Electric Schneider Electric EcoStruxure Power Monitoring Expert is a device for power distribution monitoring in IoT...

5.3CVSS6.4AI score0.00277EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.15 views

Schneider Electric EcoStruxure IT Data Center Expert 代码问题漏洞

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A server-side request forgery vulnerability exists in Schneider...

6.3CVSS6.6AI score0.00486EPSS
SaveExploits2References1
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.18 views

Schneider Electric EcoStruxure IT Data Center Expert 代码问题漏洞

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A code issue vulnerability exists in Schneider Electric EcoStruxu...

5.9CVSS6.5AI score0.00411EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.12 views

Schneider Electric EcoStruxure IT Data Center Expert 安全特征问题漏洞

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. Schneider Electric EcoStruxure IT Data Center Expert suffers from...

8.9CVSS6.4AI score0.00206EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2025/07/11 12:00 a.m.11 views

Schneider Electric EcoStruxure IT Data Center Expert 安全漏洞

Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A security vulnerability exists in Schneider Electric EcoStruxure...

7.2CVSS6.3AI score0.00191EPSS
SaveExploits1References1
Packet Storm
Packet Storm
added 2025/07/10 12:00 a.m.153 views

📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Server-Side Request Forgery

Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below insecurely forward HTTP requests based on user-controlled values, enabling an unauthenticated user to coerce the web application into sending data to arbitrary locations, such as the SMTP service listening on localhost...

6.3CVSS7.6AI score0.00486EPSS
SaveExploits2
Packet Storm
Packet Storm
added 2025/07/10 12:00 a.m.124 views

📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Root Password Discovery

Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below use logic contained within a JAR file and the MAC address to compute a "random" password for the root account. With access to the JAR file and knowledge of the MAC address, it is possible to determine the root password...

8.9CVSS7.5AI score0.00206EPSS
SaveExploits1
Packet Storm
Packet Storm
added 2025/07/10 12:00 a.m.219 views

📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Privilege Escalation

Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below contain a Charon executable that can be used by a low-privileged attacker to obtain root privileges. The Charon executable and configuration appears to be a local method for adding and removing services that run within th...

7.2CVSS7AI score0.00341EPSS
SaveExploits2
Packet Storm
Packet Storm
added 2025/07/10 12:00 a.m.162 views

📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Remote Command Execution

Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below have a configuration modification issue where sufficient input sanitization is not performed on the value provided for the hostname of the appliance. The hostname variable can include a command terminator and subsequent...

7.2CVSS7.5AI score0.00341EPSS
SaveExploits2
Packet Storm
Packet Storm
added 2025/07/10 12:00 a.m.221 views

📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 XML Injection

Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below has a DataExchange route that allows the XML body of SOAP requests to contain references to external entities. This allows an unauthenticated attacker to read local files, perform server-side request forgery, and overwhel...

5.9CVSS7.3AI score0.00411EPSS
SaveExploits1
KoreLogic Security
KoreLogic Security
added 2025/07/09 12:00 a.m.21 views

Schneider Electric EcoStruxure IT Data Center Expert Privilege Escalation

Vulnerability Details Affected Vendor: Schneider Electric Affected Product: EcoStruxure IT Data Center Expert Affected Version: 8.3 and prior Platform: CentOS CWE Classification: CWE-266: Incorrect Privilege Assignment CVE ID: CVE-2025-50124 2. Vulnerability Description The Data Center Expert...

7.2CVSS7.4AI score0.00341EPSS
SaveExploits2Affected Software1
KoreLogic Security
KoreLogic Security
added 2025/07/09 12:00 a.m.19 views

Schneider Electric EcoStruxure IT Data Center Expert Root Password Discovery

Vulnerability Details Affected Vendor: Schneider Electric Affected Product: EcoStruxure IT Data Center Expert Affected Version: 8.3 and prior Platform: CentOS CWE Classification: CWE-6311: Insufficient Entropy CVE ID: CVE-2025-50122 2. Vulnerability Description The Data Center Expert "DCE"...

8.9CVSS7.3AI score0.00206EPSS
SaveExploits1Affected Software1
Rows per page
Query Builder