Lucene search
+L

267 matches found

CVE
CVE
added 2024/01/31 5:46 p.m.65 views

CVE-2023-5390

CVE-2023-5390 affects Honeywell ControlEdge VirtualUOC and ControlEdge UOC. The connected documents confirm an absolute path traversal flaw that could allow an attacker to read files from the controller over the network, exposing limited device information. The issue is triggered through unauthor...

5.3CVSS5.5AI score0.0057EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2024/01/31 5:46 p.m.48 views

CVE-2023-5390

An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends...

5.3CVSS5.4AI score0.0057EPSS
SaveExploits0References2
Prion
Prion
added 2024/01/30 8:15 p.m.26 views

Design/Logic Flaw

An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files...

5CVSS7.2AI score0.00779EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2024/01/30 8:00 p.m.3 views

CVE-2023-5389

An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files...

9.1CVSS7.2AI score0.00779EPSS
SaveExploits0References2
CVE
CVE
added 2024/01/30 8:00 p.m.88 views

CVE-2023-5389

Honeywell CVE-2023-5389 affects Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. The vulnerability involves use of a dangerous method/function in the Configuration Handler that could allow an attacker to modify files, potentially causing configuration changes or malicious code execu...

9.1CVSS7.5AI score0.00779EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
added 2024/01/30 12:00 a.m.9 views

PT-2024-1408 · Honeywell · Honeywell Experion Controledge Virtualuoc +1

Name of the Vulnerable Software and Affected Versions: Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC affected versions not specified Description: The issue is related to the use of dangerous methods or functions in the Configuration Handler component of the Honeywell Experion...

9.1CVSS7AI score0.00779EPSS
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2024/01/30 12:00 a.m.21 views

PT-2024-1736 · Honeywell · Honeywell Experion Controledge Virtualuoc +1

Name of the Vulnerable Software and Affected Versions: Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC affected versions not specified Description: The issue is related to incorrect restriction of directory path names with limited access, potentially allowing an attacker to read fil...

5.3CVSS6.7AI score0.0057EPSS
SaveExploits0References8
Tenable Nessus
Tenable Nessus
added 2023/09/05 12:00 a.m.42 views

Honeywell Experion PKS, LX and PlantCruise Uncontrolled Resource Consumption (CVE-2023-26597)

Controller DoS due to buffer overflow in the handling of a specially crafted message received by the controller. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...

7.5CVSS7.8AI score0.00636EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/05 12:00 a.m.21 views

Honeywell Experion PKS, LX and PlantCruise Insufficient Verification of Data Authenticity (CVE-2023-25178)

Controller may be loaded with malicious firmware which could enable remote code execution This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid501611;...

9.8CVSS8.5AI score0.0052EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/05 12:00 a.m.27 views

Honeywell Experion PKS, LX and PlantCruise Improper Encoding or Escaping of Output (CVE-2023-24480)

Controller DoS due to stack overflow when decoding a message from the server This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid501610;...

9.8CVSS7.5AI score0.00718EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2023/07/31 12:00 a.m.14 views

The vulnerabilities of the microprogramming software for Honeywell Experion PKS programmable logic controllers, the measurement and computing controllers Experion LX, and the distribution control system Experion PlantCruise allow a intruder to execute arbitrary code.

The vulnerability of microprogrammed software in Honeywell Experion PKS programmable logic controllers, as well as in measurement and control controllers Experion LX, and the distribution control system Experion PlantCruise, is related to buffer overflow in dynamic memory. Exploiting this...

10CVSS7.9AI score0.00652EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.18 views

The vulnerabilities of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Honeywell Experion LX measurement and control controllers, and the Experion PlantCruise distribution control system allow a intruder to gain unauthorized access to protected information.

The vulnerabilities of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Honeywell Experion LX measurement and control controllers, and the Experion PlantCruise distribution control system are related to insufficient data authentication checks. Exploiting these...

7.8CVSS7.8AI score0.0052EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.13 views

The vulnerabilities of the microprogramming software for Honeywell Experion PKS programmable logic controllers, the measurement and computing controllers Experion LX, and the distribution control system Experion PlantCruise allow a intruder to execute arbitrary code.

The vulnerabilities of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Experion LX measurement and control controllers, and the Experion PlantCruise distribution control system are related to the restoration of unreliable data in memory. Exploiting these...

10CVSS7.7AI score0.00706EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.10 views

The vulnerabilities of the microprogrammed software in Honeywell Experion PKS programmable logic controllers, Honeywell Experion LX measurement and control controllers, and the Experion PlantCruise distribution control system allow a intruder to trigger malfunctions during maintenance operations.

The vulnerabilities of microprogrammed software in Honeywell Experion PKS programmable logic controllers, as well as in measurement and control controllers Experion LX, and the distribution control system Experion PlantCruise, are related to improper cleaning or release of resources. Exploitation...

7.8CVSS7.2AI score0.00636EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.11 views

The vulnerabilities of the microprogramming software for Honeywell Experion PKS programmable logic controllers, the measurement and computing controllers Experion LX, and the distribution control system Experion PlantCruise allow a intruder to execute arbitrary code.

The vulnerability of microprogrammed software in Honeywell Experion PKS programmable logic controllers, as well as in measurement and control controllers Experion LX, and the distribution control system Experion PlantCruise, is related to buffer overflow in dynamic memory. Exploiting this...

10CVSS7.9AI score0.00662EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.8 views

The vulnerabilities of the microprogramming software for Honeywell Experion PKS programmable logic controllers, the measurement and computing controllers Experion LX, and the distribution control system Experion PlantCruise allow a intruder to execute arbitrary code.

The vulnerabilities of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Experion LX measurement and control controllers, and the Experion PlantCruise distribution control system are related to improper code generation. Exploiting these vulnerabilities could allow...

10CVSS7.7AI score0.00601EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.11 views

The vulnerabilities of the microprogramming software for Honeywell Experion PKS programmable logic controllers, the measurement and computing controllers Experion LX, and the distribution control system Experion PlantCruise allow a intruder to execute arbitrary code.

The vulnerability of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Experion LX measurement and control controllers, and Experion PlantCruise distribution systems is related to buffer overflow in the stack. Exploiting this vulnerability could allow an attacker...

10CVSS7.9AI score0.00718EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/28 12:00 a.m.11 views

The vulnerabilities of microprogramming software in Honeywell Experion PKS programmable logic controllers, Honeywell Experion LX measurement and control controllers, and the Experion PlantCruise distribution control system allow attackers to compromise the confidentiality, integrity, and accessibility of protected information.

The vulnerabilities of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Experion LX measurement and control controllers, and Experion PlantCruise distribution systems are related to insufficient testing of value return. Exploitation of these vulnerabilities could...

10CVSS7.2AI score0.00569EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2023/07/27 12:00 a.m.10 views

The vulnerabilities of the microprogramming software for Honeywell Experion PKS programmable logic controllers, the measurement and computing controllers Experion LX, and the distribution control system Experion PlantCruise allow a intruder to execute arbitrary code.

The vulnerability of microprogrammed software in Honeywell Experion PKS programmable logic controllers, Experion LX measurement and control controllers, and Experion PlantCruise distribution systems is related to buffer overflow in the stack. Exploiting this vulnerability could allow an attacker...

10CVSS7.9AI score0.00652EPSS
SaveExploits0References4
The Hacker News
The Hacker News
added 2023/07/14 2:41 p.m.140 views

Critical Security Flaws Uncovered in Honeywell Experion DCS and QuickBlox Services

Multiple security vulnerabilities have been discovered in various services, including Honeywell Experion distributed control system DCS and QuickBlox, that, if successfully exploited, could result in severe compromise of affected systems. Dubbed Crit.IX, the nine flaws in the Honeywell Experion D...

9.8CVSS9.2AI score0.12823EPSS
SaveExploits5
Rows per page
Query Builder