Lucene search
+L

286 matches found

NVD
NVD
added 2018/03/08 5:29 p.m.36 views

CVE-2018-4840

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

7.5CVSS7.4AI score0.01777EPSS
SaveExploits0References2
Prion
Prion
added 2018/03/08 5:29 p.m.24 views

Authorization

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

5CVSS7.5AI score0.01777EPSS
SaveExploits0References2Affected Software5
CVE
CVE
added 2018/03/08 5:00 p.m.81 views

CVE-2018-4838

CVE-2018-4838 affects Siemens EN100 Ethernet module variants (IEC 61850 < V4.30, DNP3 < V1.04, PROFINET IO, Modbus TCP, IEC 104

7.5CVSS7.5AI score0.01404EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2018/03/08 5:00 p.m.85 views

CVE-2018-4840

CVE-2018-4840 affects Siemens DIGSI 4 and EN100 Ethernet modules (DNP3, IEC 104, IEC 61850, Modbus TCP, PROFINET IO). The issue allows an unauthenticated remote attacker to upload a modified device configuration that overwrites the access-authorization passwords. Affected products include DIGSI 4...

7.5CVSS7.4AI score0.01777EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2018/03/08 5:00 p.m.38 views

CVE-2018-4840

A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...

7.5AI score0.01777EPSS
SaveExploits0References1
zdt
zdt
added 2018/02/17 12:00 a.m.73 views

Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module < 4.25 - Denial of Service Exploit

Exploit for hardware platform in category dos / poc Exploit Title: Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module V4.25 - Denial of Service Exploit Author: M. Can Kurnaz Contact: https://twitter.com/0x43414e Vendor Homepage: https://www.siemens.com Version: All devices that include...

7.8CVSS9.2AI score0.74497EPSS
SaveExploits7
Packet Storm
Packet Storm
added 2018/02/16 12:00 a.m.57 views

Siemens SIPROTEC 4 / Compact EN100 Ethernet Module Denial Of Service

Exploit Title: Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module V4.25 - Denial of Service Date: 14.02.2018 Exploit Author: M. Can Kurnaz Contact: https://twitter.com/0x43414e Vendor Homepage: https://www.siemens.com Version: All devices that include the EN100 Ethernet module version...

7.8CVSS9.2AI score0.74497EPSS
SaveExploits7
Exploit DB
Exploit DB
added 2018/02/16 12:00 a.m.86 views

Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module < 4.25 - Denial of Service

Exploit Title: Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module V4.25 - Denial of Service Date: 14.02.2018 Exploit Author: M. Can Kurnaz Contact: https://twitter.com/0x43414e Vendor Homepage: https://www.siemens.com Version: All devices that include the EN100 Ethernet module version...

7.8CVSS8.6AI score0.74497EPSS
SaveExploits7
Zero Day Initiative
Zero Day Initiative
added 2017/07/11 12:00 a.m.85 views

Fatek Automation PLC Ethernet Module Configuration Tool Stack-based Buffer Overflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Fatek Automation PLC Ethernet Module Configuration Tool. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The...

9.8CVSS4AI score0.04414EPSS
SaveExploits0References1
ICS
ICS
added 2017/07/06 12:00 a.m.69 views

Siemens SIPROTEC 4 and SIPROTEC Compact (Update C)

CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the updated...

10CVSS1.5AI score0.74497EPSS
SaveExploits7References49
ICS
ICS
added 2017/07/04 12:00 a.m.111 views

ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)

CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the updated...

7.8CVSS8.5AI score0.74497EPSS
SaveExploits7References9
VulnCheck KEV
VulnCheck KEV
added 2017/06/12 12:00 a.m.9 views

VulnCheck KEV: CVE-2015-5374

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant...

7.8CVSS7.3AI score0.74497EPSS
SaveExploits7References1
CNVD
CNVD
added 2017/03/27 12:00 a.m.24 views

Fatek Automation PLC Ethernet Module Stack Buffer Overflow Vulnerability

Fatek Automation PLC is a controller developed by Fatek Automation. A stack-based buffer overflow vulnerability exists in the Fatek Automation PLC Ethernet Module. A remote attacker could use this vulnerability to execute arbitrary code in the context of the affected application, which could also...

9.8CVSS8.1AI score0.04414EPSS
SaveExploits0References1
OSV
OSV
added 2017/03/16 4:59 a.m.10 views

CVE-2017-6023

An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ethercfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions pri...

9.8CVSS6.6AI score0.04414EPSS
SaveExploits0References2
NVD
NVD
added 2017/03/16 4:59 a.m.26 views

CVE-2017-6023

An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ethercfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions pri...

9.8CVSS10AI score0.04414EPSS
SaveExploits0References2
Prion
Prion
added 2017/03/16 4:59 a.m.17 views

Stack overflow

An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ethercfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions pri...

9CVSS9.8AI score0.04414EPSS
SaveExploits0References2Affected Software4
CVE
CVE
added 2017/03/16 3:49 a.m.72 views

CVE-2017-6023

Affects Fatek Automation PLC Ethernet Module; Ether_cfg tool on CBEH/CBE/CM55E/CM25E (pre V3.6 Build 170215). Root cause: stack-based buffer overflow in ether_cfg.exe due to improper length checking. Impact: remote code execution or device crash. Mitigation: upgrade to the patched ether_cfg tool ...

9.8CVSS9.8AI score0.04414EPSS
SaveExploits0References2Affected Software4
Cvelist
Cvelist
added 2017/03/16 3:49 a.m.34 views

CVE-2017-6023

An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ethercfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions pri...

9.9AI score0.04414EPSS
SaveExploits0References2
ICS
ICS
added 2017/03/14 12:00 a.m.104 views

FATEK Automation PLC Ethernet Module

CVSS v3 7.3 ATTENTION: Remotely exploitable. Low skill level to exploit. Vendor: FATEK Automation Equipment: PLC Ethernet Module Vulnerability: Stack-based buffer overflow AFFECTED PRODUCTS The affected Ethercfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to...

9.8CVSS10AI score0.04414EPSS
SaveExploits0References3
CNVD
CNVD
added 2016/11/14 12:00 a.m.10 views

Land Attack Vulnerability in Schneider 140NOE77101 Ethernet Module

The 40NOE77101 is an Ethernet communication module for Schneider's Quantum series PLCs. A Land attack vulnerability exists in the TCP/IP stack of the Schneider 140NOE77101 Ethernet module. Since the program sends TCP SYN messages with the same source and destination IP both IP addresses of the...

6.8AI score
SaveExploits0
Rows per page
Query Builder