8884 matches found
PT-2022-9875 · Brocade · Brocade Fabric Os
Name of the Vulnerable Software and Affected Versions: Brocade Fabric OS versions 7.4.1b through 7.4.1.x Brocade Fabric OS versions 7.3.1d through 7.3.x Description: A vulnerability in Brocade Fabric OS could allow local users to conduct privileged directory transversal. The affected versions hav...
CLSA-2022-1659639100 Fixed CVEs in vim: CVE-2022-2345, CVE-2022-2344, CVE-2022-2343, CVE-2022-2522
CVE-2022-2345: fix using freed memory with recursive substitute - CVE-2022-2344: fix reading past end of completion with duplicate match - CVE-2022-2343: fix reading past end of completion with a long line and 'infercase' set - CVE-2022-2522: fix accessing uninitialized memory when completing...
CLSA-2022-1659637855 Fixed CVEs in vim: CVE-2022-2344, CVE-2022-2345, CVE-2022-2522, CVE-2022-2343
CVE-2022-2345: fix using freed memory with recursive substitute - CVE-2022-2344: fix reading past end of completion with duplicate match - CVE-2022-2343: fix reading past end of completion with a long line and 'infercase' set - CVE-2022-2522: fix accessing uninitialized memory when completing...
CVE-2022-35236
In BIG-IP Versions 16.1.x before 16.1.2.2, 15.1.x before 15.1.6.1, and 14.1.x before 14.1.5, when an HTTP2 profile is configured on a virtual server, undisclosed traffic can cause an increase in memory resource utilization. Note: Software versions which have reached End of Technical Support EoTS...
CVE-2022-33968
In BIG-IP Versions 17.0.x before 17.0.0.1, 16.1.x before 16.1.3.1, 15.1.x before 15.1.6.1, 14.1.x before 14.1.5.1, and all versions of 13.1.x, when an LTM monitor or APM SSO is configured on a virtual server, and NTLM challenge-response is in use, undisclosed traffic can cause a buffer over-read...
Privilege escalation
In BIG-IP Versions 16.1.x before 16.1.3.1, 15.1.x before 15.1.6.1, 14.1.x before 14.1.5.1, and all versions of 13.1.x, an authenticated attacker with Resource Administrator or Manager privileges can create or modify existing monitor objects in the Configuration utility in an undisclosed manner...
Design/Logic Flaw
In BIG-IP Versions 17.0.x before 17.0.0.1 and 16.1.x before 16.1.3.1, when source-port preserve-strict is configured on an HTTP Message Routing Framework MRF virtual server, undisclosed traffic may cause the Traffic Management Microkernel TMM to produce a core file and the connection to terminate...
CVE-2022-35728 iControl REST vulnerability CVE-2022-35728
In BIG-IP Versions 17.0.x before 17.0.0.1, 16.1.x before 16.1.3.1, 15.1.x before 15.1.6.1, 14.1.x before 14.1.5.1, and all versions of 13.1.x, and BIG-IQ version 8.x before 8.2.0 and all versions of 7.x, an authenticated user's iControl REST token may remain valid for a limited time after logging...
CVE-2022-28668
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sante DICOM Viewer Pro 11.9.2. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the...
CVE-2022-34862
In BIG-IP Versions 16.1.x before 16.1.3.1, 15.1.x before 15.1.6.1, 14.1.x before 14.1.5, and all versions of 13.1.x, when an LTM virtual server is configured to perform normalization, undisclosed requests can cause the Traffic Management Microkernel TMM to terminate. Note: Software versions which...
CVE-2022-35735
In BIG-IP Versions 16.1.x before 16.1.3.1, 15.1.x before 15.1.6.1, 14.1.x before 14.1.5.1, and all versions of 13.1.x, an authenticated attacker with Resource Administrator or Manager privileges can create or modify existing monitor objects in the Configuration utility in an undisclosed manner...
CVE-2022-34865
In BIG-IP Versions 15.1.x before 15.1.6.1, 14.1.x before 14.1.5, and all versions of 13.1.x, Traffic Intelligence feeds, which use HTTPS, do not verify the remote endpoint identity, allowing for potential data poisoning. Note: Software versions which have reached End of Technical Support EoTS are...
qemu security update
15:4.2.1-18.el7 - block: introduce maxhwiov for use in scsi-generic Paolo Bonzini Orabug: 33785156 - file-posix: try BLKSECTGET on block devices too, do not round to power of 2 Paolo Bonzini Orabug: 33785156 - block: add maxhwtransfer to BlockLimits Paolo Bonzini Orabug: 33785156 - block-backend:...
HPESBST04353 rev.1 - HPE B-series Fibre Channel SAN Switch Brocade Fabric OS (FOS), Directory Traversal
Potential Security Impact: Local: Directory Traversal; Remote: Directory Traversal SUPPORTED SOFTWARE VERSIONS: ONLY impacted versions are listed. HPE 8/8 SAN Switch - v7.4.1b and v7.3.1d HPE 8/24 SAN Switch - v7.4.1b and v7.3.1d Brocade 8Gb SAN Switch for HPE BladeSystem c-Class - v7.4.1b and...
[SECURITY] Fedora 36 Update: golang-sourcegraph-appdash-0-0.10.20210113gitebfcffb.fc36
Appdash is an application tracing system for Go, based on Google's Dapper and Twitter's Zipkin. Appdash allows you to trace the end-to-end handling of requests and operations in your application for perf and debugging. It displays timings and application-specific metadata for each step, and it...
Multiple vulnerabilities in Nintendo Wi-Fi Network Adaptor WAP-001
Overview Nintendo Wi-Fi Network Adaptor provided by Nintendo Co.,Ltd. contains multiple vulnerabilities listed below. OS command injection CWE-78 - CVE-2022-36381 Buffer overflow CWE-121 - CVE-2022-36293 Taizoh Tsukamoto of Mitsui Bussan Secure Directions, Inc reported these vulnerabilities to IP...
SUSE-SU-2022:2567-1 Important update for SUSE Manager 4.2.8 Release Notes
This update for SUSE Manager 4.2.8 Release Notes provides the following additions: Release notes for SUSE Manager: - Update to 4.2.8 Notification about SUSE Manager end-of-life has been added CVEs fixed CVE-2022-31248 Bugs mentioned bsc1179962, bsc1182742, bsc1189501, bsc1192850, bsc1193032...
CVE-2022-30272
The Motorola ACE1000 RTU through 2022-05-02 mishandles firmware integrity. It utilizes either the STS software suite or ACE1000 Easy Configurator for performing firmware updates. In case of the Easy Configurator, firmware updates are performed through access to the Web UI where file system, kerne...
OESA-2022-1781 log4j12 security update
With log4j it is possible to enable logging at runtime without modifying the application binary. Security Fixes: By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converte...
BSA-2022-2012
Security Advisory ID : BSA-2022-2012 Component : Brocade Fabric OS Revision : 1.1: Final Brocade has received a report from Black Lantern Security of a potential Privileged Directory Traversal vulnerability on Brocade Fabric OS: v7.4.1b, v7.3.1d stating that: “From within the restricted shell...