5460 matches found
CVE-2022-29948
Due to an insecure design, the Lepin EP-KP001 flash drive through KP001V19 is vulnerable to an authentication bypass attack that enables an attacker to gain access to the stored encrypted data. Normally, the encrypted disk partition with this data is unlocked by entering the correct passcode 6 to...
CVE-2022-29948
Due to an insecure design, the Lepin EP-KP001 flash drive through KP001V19 is vulnerable to an authentication bypass attack that enables an attacker to gain access to the stored encrypted data. Normally, the encrypted disk partition with this data is unlocked by entering the correct passcode 6 to...
Authentication flaw
Due to an insecure design, the Lepin EP-KP001 flash drive through KP001V19 is vulnerable to an authentication bypass attack that enables an attacker to gain access to the stored encrypted data. Normally, the encrypted disk partition with this data is unlocked by entering the correct passcode 6 to...
CVE-2022-29948
Due to an insecure design, the Lepin EP-KP001 flash drive through KP001V19 is vulnerable to an authentication bypass attack that enables an attacker to gain access to the stored encrypted data. Normally, the encrypted disk partition with this data is unlocked by entering the correct passcode 6 to...
CVE-2022-29948
Due to an insecure design, the Lepin EP-KP001 flash drive through KP001V19 is vulnerable to an authentication bypass attack that enables an attacker to gain access to the stored encrypted data. Normally, the encrypted disk partition with this data is unlocked by entering the correct passcode 6 to...
CVE-2022-29948
CVE-2022-29948 affects Lepin EP-KP001 (KP001_V19) USB flash drive. The root cause is insecure hardware design allowing an attacker to bypass password authentication by replacing the device’s microcontroller with one controlled by the attacker, whose passcode is known. This enables unlocking the e...
PT-2022-19929 · Lepin · Lepin Ep-Kp001
Name of the Vulnerable Software and Affected Versions: Lepin EP-KP001 versions through KP001 V19 Description: The issue is due to an insecure design, allowing an authentication bypass attack. This enables an attacker to gain access to stored encrypted data by replacing the microcontroller on a...
CVE-2022-25804
An issue was discovered in the IGEL Universal Management Suite UMS 6.07.100. Insecure permissions for the serverconfig registry key under JavaSoft\Prefs\de\igel\rm\config in HKEYLOCALMACHINE\SOFTWARE allow an unprivileged local attacker to read the encrypted dbuser and dbpassword values for the U...
CVE-2022-25804
An issue was discovered in the IGEL Universal Management Suite UMS 6.07.100. Insecure permissions for the serverconfig registry key under JavaSoft\Prefs\de\igel\rm\config in HKEYLOCALMACHINE\SOFTWARE allow an unprivileged local attacker to read the encrypted dbuser and dbpassword values for the U...
Hardcoded credentials
An issue was discovered in the IGEL Universal Management Suite UMS 6.07.100. A hardcoded DES key in the PrefDBCredentials class allows an attacker, who has discovered encrypted superuser credentials, to decrypt those credentials using a static 8-byte DES key...
Design/Logic Flaw
An issue was discovered in the IGEL Universal Management Suite UMS 6.07.100. Insecure permissions for the serverconfig registry key under JavaSoft\Prefs\de\igel\rm\config in HKEYLOCALMACHINE\SOFTWARE allow an unprivileged local attacker to read the encrypted dbuser and dbpassword values for the U...
CVE-2022-25804
An issue was discovered in the IGEL Universal Management Suite UMS 6.07.100. Insecure permissions for the serverconfig registry key under JavaSoft\Prefs\de\igel\rm\config in HKEYLOCALMACHINE\SOFTWARE allow an unprivileged local attacker to read the encrypted dbuser and dbpassword values for the U...
CVE-2022-25806
IGEL UMS 6.07.100 contains a hardcoded DES key in PrefDBCredentials, enabling an attacker who has obtained encrypted superuser credentials to decrypt them with a static 8-byte DES key. This affects IGEL Universal Management Suite and allows confidentiality/integrity/availability impact as describ...
IGEL Universal Management Suite 安全漏洞
The IGEL Universal Management Suite IGEL UMS is a single management solution from IGEL Germany. It can be used for up to tens of thousands of endpoints running IGEL OS. A security vulnerability in IGEL Universal Management Suite UMS version 6.07.100, which stems from insecure permissions in the...
IGEL Universal Management Suite 信任管理问题漏洞
The IGEL Universal Management Suite IGEL UMS is a single management solution from IGEL Germany. It can be used for up to tens of thousands of endpoints running IGEL OS. A security vulnerability exists in IGEL Universal Management Suite UMS version 6.07.100, which stems from a hard-coded DES key i...
CVE-2022-28384
An issue was discovered in certain Verbatim drives through 2022-03-31. Due to an insecure design, they allow an offline brute-force attack for determining the correct passcode, and thus gaining unauthorized access to the stored encrypted data. This affects Keypad Secure USB 3.2 Gen 1 Drive Part...
CVE-2022-28384
An issue was discovered in certain Verbatim drives through 2022-03-31. Due to an insecure design, they allow an offline brute-force attack for determining the correct passcode, and thus gaining unauthorized access to the stored encrypted data. This affects Keypad Secure USB 3.2 Gen 1 Drive Part...
CVE-2022-28384
An issue was discovered in certain Verbatim drives through 2022-03-31. Due to an insecure design, they allow an offline brute-force attack for determining the correct passcode, and thus gaining unauthorized access to the stored encrypted data. This affects Keypad Secure USB 3.2 Gen 1 Drive Part...
CVE-2022-24296
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...
Design/Logic Flaw
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...