134 matches found
CVE-2020-11438
CVE-2020-11438 concerns LibreHealth EMR v2.0.0, where a systemic CSRF vulnerability is reported. The connected records characterize the issue as a cross-site request forgery affecting LibreHealth EMR 2.0.0, with attacker‑summoned unintended requests via a compromised or tricked environment, per s...
CVE-2020-11438
LibreHealth EMR v2.0.0 is affected by systemic CSRF...
CVE-2020-11436
LibreHealth EMR v2.0.0 is vulnerable to XSS that results in the ability to force arbitrary actions on behalf of other users including administrators...
CVE-2020-11436
LibreHealth EMR v2.0.0 is reported vulnerable to cross-site scripting (XSS) that can force arbitrary actions on behalf of other users, including administrators. The connected sources confirm the affected product and the impact (unauthorized actions by different user roles), but they do not provid...
CVE-2020-11437
LibreHealth EMR v2.0.0 is affected by SQL injection allowing low-privilege authenticated users to enumerate the database...
CVE-2020-11437
CVE-2020-11437 affects LibreHealth EMR v2.0.0. The vulnerability is a SQL injection that allows low-privilege authenticated users to enumerate the database. The available documents confirm the affected product/version and the impact (database enumeration), but do not provide remediation steps or ...
CVE-2020-11439
LibreHealth EMR v2.0.0 is affected by a Local File Inclusion issue allowing arbitrary PHP to be included and executed within the EMR application...
CVE-2020-11439
CVE-2020-11439 affects LibreHealth EMR v2.0.0. The connected sources describe a Local File Inclusion vulnerability that enables inclusion and execution of arbitrary PHP within the EMR application. The datasets consistently identify the impact as arbitrary code execution via LFI, but do not provid...
CVE-2020-12036
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12037
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
Design/Logic Flaw
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
Design/Logic Flaw
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12036
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12037
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
The vulnerability of the OpenOffice office suite relates to the issue of operations occurring outside the buffer boundaries in memory. This allows attackers to gain access to confidential data, compromise its integrity, and cause service failures.
The vulnerability of the OpenOffice office suite is related to the issue of operations occurring outside the buffer boundaries in memory. Exploiting this vulnerability can allow an attacker to gain access to confidential data, compromise its integrity, and even cause service failures through...
Cross site request forgery (csrf)
goform/formEMR30 in Sumavision Enhanced Multimedia Router EMR 3.0.4.27 allows creation of arbitrary users with elevated privileges administrator on a device, as demonstrated by a setString=newuseradministrator123456 request...
CVE-2020-10181
Sumavision Enhanced Multimedia Router (EMR) 3.0.4.27 is affected by a cross-site request forgery (CSRF) vulnerability (CVE-2020-10181) in goform/formEMR30 that enables creation of arbitrary administrator users. Exploitation demonstrated via a payload like setString=new_useradministrator sent to /...
CVE-2019-13557
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information...
CVE-2019-13557
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information...
Information disclosure
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information...