CVE-2025-5241 Denial-of-Service Vulnerability in MELSEC iQ-F Series
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series allows a remote unauthenticated attacker to lockout legitimate users for a certain period by repeatedly attempting to login with incorrect passwords. The legitimate users will be unabl...
CVE-2025-5241
CVE-2025-5241 affects Mitsubishi Electric MELSEC iQ-F Series. A remote, unauthenticated attacker can trigger a denial-of-service by exploiting an overly restrictive account lockout mechanism, causing legitimate users to be blocked for a period after repeated incorrect login attempts. The impact i...
CVE-2025-5241 Denial-of-Service Vulnerability in MELSEC iQ-F Series
Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series allows a remote unauthenticated attacker to lockout legitimate users for a certain period by repeatedly attempting to login with incorrect passwords. The legitimate users will be unabl...
Schneider Electric EcoStruxure IT Data Center Expert 操作系统命令注入漏洞
Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. Schneider Electric EcoStruxure IT Data Center Expert suffers from...
Schneider Electric EcoStruxure IT Data Center Expert 代码注入漏洞
Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A code injection vulnerability exists in Schneider Electric...
Schneider Electric EcoStruxure IT Data Center Expert 代码问题漏洞
Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A code issue vulnerability exists in Schneider Electric EcoStruxu...
Schneider Electric EcoStruxure IT Data Center Expert 代码问题漏洞
Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. A server-side request forgery vulnerability exists in Schneider...
Schneider Electric EcoStruxure IT Data Center Expert 安全特征问题漏洞
Schneider Electric EcoStruxure IT Data Center Expert is a scalable monitoring software from Schneider Electric France that collects, organizes, and distributes critical device information to provide a comprehensive view of devices. Schneider Electric EcoStruxure IT Data Center Expert suffers from...
Mitsubishi Electric MELSEC iQ-F Series 安全漏洞
Mitsubishi Electric MELSEC iQ-F Series is a series of simple motion controllers from Mitsubishi Electric Japan. A security vulnerability exists in the Mitsubishi Electric MELSEC iQ-F Series that stems from an overly strict account lockout mechanism that could allow a remote, unauthenticated...
CVE-2025-50130
A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD. Opening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution...
CVE-2025-5022
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product measurement unit and display unit to...
CVE-2025-5023
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product measurement unit and display unit to...
CVE-2025-5023
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product measurement unit and display unit to...
CVE-2025-5023
The CVE-2025-5023 entry affects Mitsubishi Electric EcoGuideTAB PV-DR004J and PV-DR004JA, all versions, with a root cause related to hard-coded credentials. An attacker in Wi‑Fi range between the measurement unit and display unit can disclose generated power data and grid-revenue information, tam...
CVE-2025-5022
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product measurement unit and display unit to...
CVE-2025-5022
CVE-2025-5022 affects Mitsubishi Electric Corporation’s photovoltaic system monitor “EcoGuideTAB” PV-DR004J (all versions) and PV-DR004JA (all versions). The vulnerability is described as a weak password requirement that enables an attacker within the Wi‑Fi range between the measurement unit and ...
CVE-2025-5022
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product measurement unit and display unit to...
📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Root Password Discovery
Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below use logic contained within a JAR file and the MAC address to compute a "random" password for the root account. With access to the JAR file and knowledge of the MAC address, it is possible to determine the root password...
📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Remote Command Execution
Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below have a configuration modification issue where sufficient input sanitization is not performed on the value provided for the hostname of the appliance. The hostname variable can include a command terminator and subsequent...
📄 Schneider Electric EcoStruxure IT Data Center Expert 8.3 Server-Side Request Forgery
Schneider Electric EcoStruxure IT Data Center Expert versions 8.3 and below insecurely forward HTTP requests based on user-controlled values, enabling an unauthenticated user to coerce the web application into sending data to arbitrary locations, such as the SMTP service listening on localhost...