Lucene search
+L

8857 matches found

ThreatPost
ThreatPost
•added 2014/01/16 7:56 a.m.•15 views

DHS Warns of Schneider Electric ClearSCADA Vulnerability

The Department of Homeland Security is warning the maintainers of industrial control systems ICS about a remotely exploitable uncontrolled resource consumption vulnerability in Schneider Electric’s ClearSCADA software. Schneider Electric says that it has developed a new version of ClearSCADA that...

1.7AI score
SaveExploits0References1
NVD
NVD
•added 2014/01/15 4:11 p.m.•33 views

CVE-2013-6142

DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remote attackers to cause a denial of service resource consumption via IP packets containing errors that trigger event-journal messages...

4.3CVSS6.6AI score0.01164EPSS
SaveExploits0References1
Prion
Prion
•added 2014/01/15 4:11 p.m.•25 views

Design/Logic Flaw

DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remote attackers to cause a denial of service resource consumption via IP packets containing errors that trigger event-journal messages...

4.3CVSS7.1AI score0.01164EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2014/01/15 3:00 p.m.•64 views

CVE-2013-6142

Summary (MODE C): Schneider Electric ClearSCADA/SCADA Expert ClearSCADA 2010 R2–R3.x and 2013 R1–R1.2 are affected by CVE-2013-6142, an uncontrolled resource consumption vulnerability in the DNP3 driver (DNP3Driver.exe). Specially crafted IP frames can trigger event journal flooding, potentially ...

4.3CVSS6.8AI score0.01164EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2014/01/15 3:00 p.m.•45 views

CVE-2013-6142

DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remote attackers to cause a denial of service resource consumption via IP packets containing errors that trigger event-journal messages...

6.6AI score0.01164EPSS
SaveExploits0References1
ICS
ICS
•added 2014/01/04 7:00 a.m.•65 views

Schneider Electric OPC Factory Server Buffer Overflow

OVERVIEW Researcher Wei Gao, formerly of IXIA, has identified a buffer overflow vulnerability in the Schneider Electric OPC Factory Server OFS application. Schneider Electric has produced a patch that mitigates this vulnerability. Wei Gao has tested the patch to validate that it resolves the...

7.8CVSS6.7AI score0.02471EPSS
SaveExploits0References10
ICS
ICS
•added 2013/12/20 7:00 a.m.•46 views

Schneider Electric PLCs Vulnerabilities

OVERVIEW --------- Begin Update B Part 1 of 2 -------- This updated advisory is a follow-up to the previous advisory update titled ICSA-13-077-01A Schneider Electric PLCs Vulnerabilities Update A that was published March 20, 2013, on the ICS-CERT Web page. It is also a follow-up to the updated...

7.4AI score
SaveExploits0References10
OpenVAS
OpenVAS
•added 2013/12/16 12:00 a.m.•17 views

Schneider Electric Modicon M340 Detection (HTTP)

HTTP based detection of Schneider Electric Modicon M340 devices. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

7.4AI score
SaveExploits0References1
ICS
ICS
•added 2013/11/16 7:00 a.m.•46 views

Schneider Electric Accutech Manager Heap Overflow

Overview This advisory provides mitigation details for a vulnerability that impacts the Schneider Electric Accutech Manager. Independent researcher Aaron Portnoy of Exodus Intelligence has identified a heap-based buffer overflow vulnerability in Schneider Electric’s Accutech Manager application...

10CVSS7.8AI score0.21527EPSS
SaveExploits1References10
Tenable Nessus
Tenable Nessus
•added 2013/11/15 12:00 a.m.•10 views

Schneider Electric Accutech Manager 'RFManagerService' SQL Injection

Binary data scadaschneiderelectricaccutechmanagersql.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2013/11/05 12:00 a.m.•21 views

Schneider Electric InduSoft Web Studio Arbitrary Script Execution

Binary data scadaindusoftwebstudioscriptexecution.nbin...

7.5CVSS7.3AI score0.02923EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2013/10/24 12:00 a.m.•19 views

Schneider Electric Accutech Manager RF Successful Authentication

Binary data 8037.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2013/10/24 12:00 a.m.•20 views

Schneider Electric Accutech Manager RF Server Detection

Binary data 8036.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2013/10/24 12:00 a.m.•17 views

Schneider Electric Accutech Manager RF Failed Authentication

Binary data 8038.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2013/10/24 12:00 a.m.•19 views

Schneider Electric Accutech Manager RF Client Detection

Binary data 8035.prm...

7.3AI score
SaveExploits0References1
ThreatPost
ThreatPost
•added 2013/10/23 2:34 p.m.•39 views

ProSoft Technology RadioLinx ControlScape PRNG vulnerability

Industrial automation software used worldwide to create and configure wireless radios that connect devices in environments such as oil and gas is vulnerable to attack by a hacker armed with an antenna from as far as 30 miles away. Though the vulnerability in the ProSoft Technology RadioLinx...

0.9AI score
SaveExploits0References2
ICS
ICS
•added 2013/10/22 6:00 a.m.•55 views

Schneider Electric IGSS Buffer Overflow

Overview Independent researcher Aaron Portnoy of Exodus Intelligence has identified a buffer overflow vulnerability in Schneider Electric’s Interactive Graphical SCADA System IGSS application. Schneider Electric has produced a patch that fully resolves this vulnerability. Aaron Portnoy has...

10CVSS6.8AI score0.21262EPSS
SaveExploits9References10
ICS
ICS
•added 2013/10/20 6:00 a.m.•63 views

Schneider Electric Authenticated Communication Risk Vulnerability

OVERVIEW ICS-CERT received a report from Schneider Electric concerning an Authenticated Communication Risk vulnerability in the Schneider Electric Software Update SESU utility. This vulnerability was reported to Schneider Electric by security researcher Arthur Gervais. The SESU is a centralized...

9.3CVSS7.3AI score0.02906EPSS
SaveExploits0References10
ThreatPost
ThreatPost
•added 2013/09/23 3:24 p.m.•11 views

ICS Vendor Fixes Hard-Coded Credential Bugs Nearly Two Years After Advisory

Nearly two years after a security researcher published details of the hard-coded credentials that ship with a slew of industrial control system products made by Schneider Electric, the company has released updated firmware that fix the problems. The vulnerabilities, which were discovered by...

7.7AI score
SaveExploits0References4
ICS
ICS
•added 2013/09/18 6:00 a.m.•75 views

Schneider Electric CitectSCADA Products Exception Handler Vulnerability (Update A)

OVERVIEW --------- Begin Update A Part 1 of 1 -------- This updated advisory is a follow-up to the original advisory titled ICSA-13-350-01 Schneider Electric SCADA Products Exception Handler Vulnerability that was published February 25, 2014, on the NCCIC/ICS-CERT web site. This advisory was...

7.8CVSS6.5AI score0.01786EPSS
SaveExploits1References10
Rows per page