8857 matches found
Buffer overflow
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a 1 CFG or 2 DAT file...
CVE-2014-8390
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a 1 CFG or 2 DAT file...
CVE-2014-8390
Schneider Electric VAMPSET software (Schneider Electric VAMPSET) is affected by CVE-2014-8390. A stack-based and a heap-based buffer overflow can be triggered by opening specially crafted COMTRADE disturbance-recording files (CFG/DAT) in vulnerable versions, allowing local privilege escalation. E...
PT-2015-4038
Name of the Vulnerable Software and Affected Versions Schneider Electric VAMPSET versions prior to 2.2.168 Description The issue concerns multiple buffer overflows that can be triggered by local users through malformed disturbance-recording data in a CFG or DAT file, potentially allowing them to...
CVE-2014-8390: Improper Restriction of Operations within the Bounds of a Memory Buffer
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a 1 CFG or 2 DAT file...
Schneider Electric InduSoft Web Studio and InTouch Machine Edition Information Disclosure Vulnerability (CNVD-2015-02057)
Schneider Electric InduSoft Web Studio and InTouch Machine Edition are both an embedded HMI software package from Schneider Electric France. A security vulnerability exists in Schneider Electric InduSoft Web Studio prior to version 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 prior to...
Schneider Electric InduSoft Web Studio and InTouch Machine Edition Information Disclosure Vulnerability (CNVD-2015-02059)
Schneider Electric InduSoft Web Studio and InTouch Machine Edition are both an embedded HMI software package from Schneider Electric France. A security vulnerability exists in Schneider Electric InduSoft Web Studio prior to version 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 prior to...
CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
CVE-2015-0998
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network...
CVE-2015-0997
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack...
CVE-2015-0996
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive...
Design/Logic Flaw
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
Default credentials
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack...
Design/Logic Flaw
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network...
Hardcoded credentials
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive...
CVE-2015-0997
Schneider Electric InduSoft Web Studio (before 7.1.3.4 SP3 Patch 4) and InTouch Machine Edition 2014 (before 7.1.3.4 SP3 Patch 4) expose an authentication flaw: the HMI UI lists all valid usernames, enabling remote brute-force access. Root cause involves use of hard-coded/cleartext credentials in...
CVE-2015-0998
CVE-2015-0998 affects Schneider Electric InduSoft Web Studio (before 7.1.3.4 SP3 Patch 4) and InTouch Machine Edition 2014 (before 7.1.3.4 SP3 Patch 4). The issue is cleartext transmission of credentials (CWE-319), enabling an attacker on an adjacent network to sniff sensitive information. Root c...
CVE-2015-0998
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network...
CVE-2015-0996
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive...
CVE-2015-0999
The CVE-2015-0999 issue affects Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4, where OPC User credentials are stored in cleartext in configuration files. This enables local attackers with access to read the files to o...