Lucene search
+L

8154 matches found

CVE
CVE
added 2013/04/04 10:00 a.m.49 views

CVE-2013-2762

The CVE-2013-2762 issue affects the Schneider Electric Magelis XBT HMI controller and is caused by a default password used for authentication of configuration uploads. This allows remote attackers to bypass access restrictions via crafted configuration data. Exploitation details or existence of i...

10CVSS7.3AI score0.02105EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2013/04/04 10:00 a.m.86 views

CVE-2013-2763

Summary (CVE-2013-2763) : The Schneider Electric M340 PLC modules are reported to be susceptible to a remote denial-of-service (resource consumption) via unspecified vectors. The vendor disputes the issue, stating it could not be duplicated and that the observed behavior could not remotely deny P...

5CVSS6.8AI score0.02133EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2013/04/04 10:00 a.m.76 views

CVE-2013-0664

CVE-2013-0664 affects Schneider Electric Modicon PLCs (Quantum 140NOE77111, 140NWM10000, M340 BMXNOE0110x, Premium TSXETY5103). The vulnerability arises in the FactoryCast feature: remote authenticated users can embed Modbus messages in SOAP HTTP POST requests, enabling arbitrary code execution o...

8.5CVSS7.1AI score0.03909EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2013/04/04 10:00 a.m.31 views

CVE-2013-0664

The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests...

6.8AI score0.03909EPSS
SaveExploits0References3
Check Point Advisories
Check Point Advisories
added 2013/04/04 12:00 a.m.53 views

Schneider Electric Interactive Graphical SCADA System Buffer Overflow (CVE-2013-0657)

A buffer overflow vulnerability exists in Schneider Electric's Interactive Graphical SCADA System IGSS application. The vulnerability is due to an integer underflow that leads to a stack buffer overflow when processing crafted input sent to ports 12397/TCP and 12399/TCP...

6.6AI score0.21262EPSS
SaveExploits9
Positive Technologies
Positive Technologies
added 2013/04/04 12:00 a.m.10 views

PT-2013-3916 · Schneider Electric · Schneider Electric M340

Name of the Vulnerable Software and Affected Versions: Schneider Electric M340 PLC modules affected versions not specified Description: The issue allows remote attackers to cause a denial of service through resource consumption via unspecified vectors. The vendor reportedly disputes this issue,...

5CVSS7.1AI score0.02133EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2013/03/18 12:00 a.m.20 views

Schneider Electric Accutech Manager Detection

Binary data scadaappschneiderelectricaccutechmanager.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2013/03/18 12:00 a.m.32 views

Schneider Electric Accutech Manager RFManagerService Heap Overflow

Binary data scadaschneiderelectricaccutechmanager202.nbin...

10CVSS7.3AI score0.21527EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2013/03/15 12:00 a.m.14 views

Schneider Electric Accutech Manager Detection (SCADA)

Binary data 6731.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2013/03/15 12:00 a.m.16 views

Schneider Electric Accutech Manager Default Credentials(SCADA)

Binary data 6732.prm...

7.3AI score
SaveExploits0References1
ICS
ICS
added 2013/02/21 7:00 a.m.62 views

Mitsubishi Electric Automation MX Component V3 ActiveX Vulnerability

OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-13-091-01 Mitsubishi Electric Automation MX Buffer Overflow Vulnerability that was published April 1, 2013, on the ICS-CERT Web siteICSA-13-091-01, http://ics-cert.us-cert.gov/alerts/ICSA-13-091-01, last accessed May 20, 2013...

10CVSS7.4AI score0.10771EPSS
SaveExploits2References10
NVD
NVD
added 2013/02/15 12:09 p.m.26 views

CVE-2013-0658

Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request...

10CVSS7.9AI score0.21527EPSS
SaveExploits1References1
Prion
Prion
added 2013/02/15 12:09 p.m.21 views

Heap overflow

Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request...

10CVSS8.6AI score0.21527EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
added 2013/02/15 11:00 a.m.36 views

CVE-2013-0658

Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request...

7.9AI score0.21527EPSS
SaveExploits1References1
CVE
CVE
added 2013/02/15 11:00 a.m.125 views

CVE-2013-0658

CVE-2013-0658 is a heap-based buffer overflow in Schneider Electric Accutech Manager’s RFManagerService.exe affecting version 2.00.1 and earlier. By sending an HTTP request to ports 2537/TCP, an attacker could remotely exploit the vulnerability to execute arbitrary code with administrator privile...

10CVSS8.2AI score0.21527EPSS
SaveExploits1References1Affected Software1
ThreatPost
ThreatPost
added 2013/02/13 8:19 p.m.38 views

Vulnerability Patched in Schneider Electric ICS Gear

The Industrial Control System CERT released an advisory this week warning of a vulnerability in a popular sensor monitoring system used in a number of critical industries, including energy, water and manufacturing. Aaron Portnoy of Exodus Intelligence discovered the flaw in the Windows-based...

10CVSS7.4AI score0.21527EPSS
SaveExploits1References3
Saint
Saint
added 2013/02/11 12:00 a.m.58 views

Schneider Electric Interactive Graphical SCADA System Data Collector Overflow

Added: 02/11/2013 CVE: CVE-2013-0657 BID: 57449 OSVDB: 89324 Background Schneider Electric Interactive Graphical SCADA System IGSS is a supervisory control and data acquisition SCADA system designed to monitor and control industrial processes. The Data Collector DC.exe component listens on port...

10CVSS7.6AI score0.21262EPSS
SaveExploits9
Packet Storm
Packet Storm
added 2013/02/11 12:00 a.m.47 views

Schneider Electric Accutech Manager Heap Overflow

Schneider Electric Accutech Manager Server Heap Overflow PoC RFManagerService - Port: 2537 I think this is the same vuln that ExodusIntel discovered. Credit also goes to Aaron Portnoy, ExodusIntel. The patch has not been released yet. Evren Yalcin, Signalsec Ltd. www.signalsec.com Download app:...

0.7AI score
SaveExploits0
Saint
Saint
added 2013/02/11 12:00 a.m.65 views

Schneider Electric Interactive Graphical SCADA System Data Collector Overflow

Added: 02/11/2013 CVE: CVE-2013-0657 BID: 57449 OSVDB: 89324 Background Schneider Electric Interactive Graphical SCADA System IGSS is a supervisory control and data acquisition SCADA system designed to monitor and control industrial processes. The Data Collector DC.exe component listens on port...

10CVSS7.5AI score0.21262EPSS
SaveExploits9
Saint
Saint
added 2013/02/11 12:00 a.m.57 views

Schneider Electric Interactive Graphical SCADA System Data Collector Overflow

Added: 02/11/2013 CVE: CVE-2013-0657 BID: 57449 OSVDB: 89324 Background Schneider Electric Interactive Graphical SCADA System IGSS is a supervisory control and data acquisition SCADA system designed to monitor and control industrial processes. The Data Collector DC.exe component listens on port...

10CVSS7.5AI score0.21262EPSS
SaveExploits9
Rows per page