8154 matches found
CVE-2013-0662
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...
PT-2015-14: Password Access in Schneider Electric InduSoft Web Studio and InTouch Machine Edition 2014
The specialists of the Positive Research center have detected a Password Access vulnerability in Schneider Electric InduSoft Web Studio and InTouch Machine Edition 2014. Systems do not encrypt user passwords, which allows attackers to access them. How to fix Update your system up to the latest...
Schneider Electric产品基于栈的缓冲区溢出漏洞
Bugtraq ID:66500 CVE ID:CVE-2013-0662 施耐德电气为100多个国家的能源及基础设施、工业、数据中心及网络、楼宇和住宅市场提供整体解决方案。 Schneider Electric多个产品使用的Modbus Serial驱动监听TCP 27700端口,当处理连接时,Modbus应用头字段会最先读入缓冲区,当在头字段指定超大缓冲区大小时可触发基于栈的缓冲区溢出,成功利用漏洞可以以应用程序上下文执行任意代码。 0 Schneider Electric TwidoSuite Versions 2.31.04 Schneider Electric PowerSui...
CVE-2013-0662
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...
CVE-2013-0662
The CVE-2013-0662 vulnerability affects Schneider Electric’s Modbus Serial Driver (ModbusDrv.exe) used by multiple Schneider Electric products. A stack-based buffer overflow is triggered when a large value is specified in the Modbus Application Header, enabling remote code execution with the user...
Patch Available for Schneider Electric Serial Modbus Driver
Schneider Electric, a leading provider of industrial control systems, recently patched a remotely exploitable vulnerability in a driver found in 11 of its products. The Industrial Control Systems Computer Emergency Response Team ICS-CERT released an advisory yesterday alerting users to the...
Default FTP Credentials (ntpupdate / ntpupdate)
It is possible to log into the remote FTP server by providing default credentials. A remote attacker could exploit this to gain access to the remote server. These credentials are known to apply to Schneider Electric Modicon M340 for Ethernet devices; however, they may apply to other FTP services ...
CVE-2014-0779
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
Design/Logic Flaw
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
CVE-2014-0779 Schneider Electric StruxureWare SCADA Expert ClearSCADA Improper Restriction of Operations within the Bounds of a Memory Buffer
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build...
CVE-2014-0779
The CVE-2014-0779 issue affects the Kepware KepServerEX V4 PLC Driver in the ServerMain.exe component of Schneider Electric StruxureWare SCADA Expert ClearSCADA, impacting multiple release/build combos listed in the NVD entry (2010 R2, 2010 R2.1, 2010 R3, 2010 R3.1, 2013 R1, 2013 R1.1, 2013 R1.1a...
Institute for Electric Grid Cybersecurity Girds Utilities
Critical infrastructure policymakers are advocating the foundation of a new entity, the Institute for Electric Grid Cybersecurity, along with a new set of guidelines, to better protect the North American electric grid from cyber-attacks and determine how to respond if the grid is ever compromised...
Schneider Electric Patches SCADA, ICS Security Vulnerabilities
The Industrial Control Systems Cyber Emergency Response Team ICS-CERT last week issued advisories warning of serious vulnerabilities in Schneider Electric SCADA gear. Schneider Electric is a supplier of energy management control products that are used in a number of critical industries in North...
Schneider Electric Floating License Manager权限提升漏洞
BUGTRAQ ID: 65873 CVECAN ID: CVE-2014-0759 Schneider Electric Floating License Manager是许可证管理器。 Schneider Electric Floating License Manager在实现上存在“未引用搜索路径或元素”漏洞,如果服务的可执行路径包含空格,攻击者可利用此漏洞执行恶意程序。 0 Schneider Electric Floating License Manager 1.0.0 - 1.4.0 厂商补丁: Schneider Electric ------------------...
CVE-2014-0774
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server OFS TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file...
CVE-2014-0759
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character...
Design/Logic Flaw
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character...
Stack overflow
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server OFS TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file...
CVE-2014-0774 Schneider Electric OFS Stack Buffer Overflow
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server OFS TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file...
CVE-2014-0759
CVE-2014-0759 affects Schneider Electric Floating License Manager versions 1.0.0–1.4.0. The root cause is an unquoted service path in a Windows service, so if the executable path contains a space, a local user can trigger execution of a Trojan horse and gain privileges by starting a malicious pro...