Lucene search
+L

8158 matches found

ICS
ICS
added 2014/10/09 6:00 a.m.42 views

Schneider Electric Telvent SAGE RTU DNP3 Improper Input Validation Vulnerability

OVERVIEW This advisory was originally posted to the US-CERT secure portal library on January 06, 2014, and is now being released to the NCCIC/ICS-CERT Web site. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation in the Schneider Electric...

5CVSS6.5AI score0.01358EPSS
SaveExploits1References10
NVD
NVD
added 2014/10/03 6:55 p.m.31 views

CVE-2014-0754

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...

10CVSS6.7AI score0.08978EPSS
SaveExploits0References5
Prion
Prion
added 2014/10/03 6:55 p.m.25 views

Directory traversal

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...

10CVSS7.2AI score0.08978EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2014/10/03 6:00 p.m.58 views

CVE-2014-0754 Schneider Electric

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...

10CVSS6.7AI score0.08978EPSS
SaveExploits0References3
CVE
CVE
added 2014/10/03 6:00 p.m.111 views

CVE-2014-0754

CVE-2014-0754 is a directory traversal vulnerability in Schneider Electric Modicon PLC Ethernet modules (SchneiderWEB). Affected Exec firmware/versions include 140CPU65x before 5.5, 140NOC78x before 1.62, 140NOE77x before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x before 6.0,...

10CVSS6.9AI score0.08978EPSS
SaveExploits0References5Affected Software1
Positive Technologies
Positive Technologies
added 2014/10/03 12:00 a.m.14 views

PT-2014-3817 · Schneider Electric · Modicon Plc Ethernet Modules +1

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec versions prior to 5.5 Schneider Electric Modicon PLC Ethernet modules 140NOC78x Exec versions prior to 1.62 Schneider Electric Modicon PLC Ethernet modules 140NOE77x Exec versions...

10CVSS7.3AI score0.08978EPSS
SaveExploits0References8
ThreatPost
ThreatPost
added 2014/10/01 11:01 a.m.7 views

Schneider Electric Fixes Remotely Exploitable Flaw in 22 Different PLCs

There’s a remotely exploitable directory traversal vulnerability in more than 20 individual products from Schneider Electric that can enable an attacker to gain control of an affected machine. The flaw allows attackers to bypass the authentication mechanism on the server and get access to resourc...

3AI score
SaveExploits0References2
NVD
NVD
added 2014/09/18 10:55 a.m.30 views

CVE-2014-5411

Multiple cross-site scripting XSS vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors...

4.9CVSS5.3AI score0.01287EPSS
SaveExploits0References3
NVD
NVD
added 2014/09/18 10:55 a.m.25 views

CVE-2014-5412

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account...

6.4CVSS6.5AI score0.01572EPSS
SaveExploits0References3
NVD
NVD
added 2014/09/18 10:55 a.m.26 views

CVE-2014-5413

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm...

6.4CVSS6.5AI score0.01028EPSS
SaveExploits0References3
Prion
Prion
added 2014/09/18 10:55 a.m.28 views

Code injection

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm...

5CVSS7AI score0.01028EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2014/09/18 10:55 a.m.25 views

Cross site scripting

Multiple cross-site scripting XSS vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors...

3.5CVSS5.6AI score0.01287EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2014/09/18 10:00 a.m.68 views

CVE-2014-5412

Schneider Electric SCADA Expert ClearSCADA/ ClearSCADA (2010 R3 through 2014 R1) contains an authentication bypass via the default guest account, enabling remote disclosure of database records. Root cause: guest user’s read access exposes sensitive data without login. Affected products/versions: ...

6.4CVSS6.7AI score0.01572EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2014/09/18 10:00 a.m.40 views

CVE-2014-5413 Schneider Electric SCADA Expert ClearSCADA Cryptographic Issues

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm...

6.4CVSS6.5AI score0.01028EPSS
SaveExploits0References2
CVE
CVE
added 2014/09/18 10:00 a.m.64 views

CVE-2014-5413

CVE-2014-5413 affects Schneider Electric StruxureWare SCADA Expert ClearSCADA (2010 R3 through 2014 R1). The root issue is weak cryptographic controls: the self-signed web certificate uses MD5, enabling potential cryptographic spoofing of servers. Additionally, ICS-CERT describes a cross-site scr...

6.4CVSS6.7AI score0.01028EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2014/09/18 10:00 a.m.44 views

CVE-2014-5412 Schneider Electric SCADA Expert ClearSCADA Improper Authentication

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account...

6.4CVSS6.5AI score0.01572EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2014/09/18 10:00 a.m.39 views

CVE-2014-5411 Schneider Electric SCADA Expert ClearSCADA Cross-site Scripting

Multiple cross-site scripting XSS vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors...

4.9CVSS5.3AI score0.01287EPSS
SaveExploits0References2
CVE
CVE
added 2014/09/18 10:00 a.m.56 views

CVE-2014-5411

Schneider Electric SCADA Expert ClearSCADA (ClearSCADA 2010 R3 through 2014 R1; SCADA Expert ClearSCADA 2013/2014 R1 variants) is affected by CVE-2014-5411, a cross-site scripting (XSS) vulnerability combined with an authentication bypass and a weak MD5-based self-signed certificate issue. The IC...

4.9CVSS5.4AI score0.01287EPSS
SaveExploits0References3Affected Software2
ICS
ICS
added 2014/09/18 6:00 a.m.77 views

Schneider Electric ProClima Command Injection Vulnerabilities

OVERVIEW NCCIC/ICS-CERT received a report from HP’s Zero Day Initiative ZDI concerning command injection vulnerabilities in Schneider Electric’s ProClima software package. These vulnerabilities were reported to ZDI by security researchers Ariele Caltabiano, Andrea Micalizzi, and Brian Gorenc...

10CVSS7.7AI score0.04436EPSS
SaveExploits0References10
ThreatPost
ThreatPost
added 2014/09/17 1:56 p.m.16 views

Series of Vulnerabilities Found in Schneider Electric SCADA Products

UPDATE–There are several unpatched, remotely exploitable vulnerabilities in a number of Schneider Electric’s SCADA products, one of which could be used to perform a shutdown of the SCADA server. Another of the vulnerabilities is an authentication bypass that could give an attacker access to...

2.1AI score
SaveExploits0References1
Rows per page
Query Builder