Lucene search
+L

8158 matches found

ThreatPost
ThreatPost
added 2015/06/23 10:47 a.m.35 views

TCP Vulnerability Haunts Wind River VxWorks Embedded OS

There is a TCP prediction vulnerability in Wind River’s widely deployed VxWorks embedded software that can enable an attacker to disrupt or spoof the TCP connections to and from target devices. VxWorks is an embedded operating system that’s used in a large number of ICS products that are deployed...

1.3AI score
SaveExploits0References1
ICS
ICS
added 2015/06/18 6:00 a.m.69 views

Schneider Electric StruxureWare Building Expert Plaintext Credentials Vulnerability

OVERVIEW Independent researcher Artyom Kurbatov has identified a cleartext transmission vulnerability in Schneider Electric’s StruxureWare Building Expert product. Schneider Electric has produced a new firmware version that mitigates this vulnerability. Artyom Kurbatov has tested the new firmware...

5CVSS6.4AI score0.01199EPSS
SaveExploits0References10
Tenable Nessus
Tenable Nessus
added 2015/06/18 12:00 a.m.38 views

Schneider Electric InduSoft Web Studio < 7.1.3.4 Multiple Information Disclosures (SEVD-2015-054-01)

Binary data scadaindusoftwebstudioSEVD2015-054-01.nbin...

5CVSS6.8AI score0.02383EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2015/06/18 12:00 a.m.30 views

Schneider Electric InduSoft Web Studio Detection

Binary data scadaappindusoftwebstudiodetect.nbin...

7.3AI score
SaveExploits0References1
ICS
ICS
added 2015/06/18 12:00 a.m.118 views

Wind River VXWorks TCP Predictability Vulnerability in ICS Devices (Update B)

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-169-01A Wind River VxWorks TCP Predictability Vulnerability in ICS Devices that was published November 5, 2015, on the NCCIC/ICS-CERT web site. Raheem Beyah, David Formby, and San Shin Jung of Georgia Tech, via a...

5.8CVSS0.03743EPSS
SaveExploits0References19
CNVD
CNVD
added 2015/06/07 12:00 a.m.15 views

Beckwith Electric TCP Incorrectly Generates TCP ISN Values Security Bypass Vulnerability

Beckwith Electric is an American transformer. A security bypass vulnerability exists in multiple Beckwith Electric products due to a program failing to properly generate the TCP initial sequence number ISN value, allowing remote attackers to exploit the vulnerability to predict the ISN value to...

6.4CVSS7AI score0.01528EPSS
SaveExploits0References1
ICS
ICS
added 2015/06/06 6:00 a.m.44 views

Schneider Electric Modicon PLC Vulnerabilities

OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-15-224-02 Schneider Electric Modicon M340 PLC Station P34 Module VulnerabilitiesICS-CERT ALERT, https://ics-cert.us-cert.gov/alerts/ICS-ALERT-15-224-02, web site last accessed September 3, 2015. that was published August 12, 2015...

6.2AI score
SaveExploits0References10
Prion
Prion
added 2015/06/05 10:59 a.m.21 views

Code injection

Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank...

6.4CVSS7.3AI score0.01528EPSS
SaveExploits0References1Affected Software5
NVD
NVD
added 2015/06/05 10:59 a.m.24 views

CVE-2014-9201

Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank...

6.4CVSS6.7AI score0.01528EPSS
SaveExploits0References1
CVE
CVE
added 2015/06/05 10:00 a.m.75 views

CVE-2014-9201

The CVE-2014-9201 issue affects Beckwith Electric devices that generate TCP initial sequence numbers (ISNs) insecurely, enabling TCP session spoofing due to predictable ISN values. Affected products include the M-6200 and M-6200A Digital Voltage Regulator Controllers (firmware before D-0198V04.07...

6.4CVSS6.9AI score0.01528EPSS
SaveExploits0References1Affected Software12
Cvelist
Cvelist
added 2015/06/05 10:00 a.m.35 views

CVE-2014-9201

Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank...

6.7AI score0.01528EPSS
SaveExploits0References1
ICS
ICS
added 2015/05/14 6:00 a.m.49 views

Schneider Electric IMT25 DTM Vulnerability

OVERVIEW Alexander Bolshev, Gleb Cherbov, and Svetlana Cherkasova of Digital Security have identified a memory corruption vulnerability in Schneider Electric IMT25 DTM component. Schneider Electric has produced a patch that mitigates this vulnerability. Digital Security has tested this patch to...

7.7CVSS8.1AI score0.01079EPSS
SaveExploits0References10
ICS
ICS
added 2015/05/02 6:00 a.m.58 views

Schneider Electric InduSoft Web Studio and InTouch Machine Edition 2014 Password Storage Vulnerability

OVERVIEW Gleb Gritsai, Alisa Esage Shevchenko, Ilya Karpov, and the team from Positive Technologies Security have found sensitive information stored in clear text in the Schneider Electric InduSoft Web Studio and InTouch Machine Edition 2014 products. Schneider Electric has released new patches t...

1.7CVSS6.7AI score0.00315EPSS
SaveExploits0References10
Tenable Nessus
Tenable Nessus
added 2015/05/01 12:00 a.m.32 views

Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX Object Multiple Buffer Overflows DoS

Binary data scadaopcfactoryserveractivex.nbin...

7.8CVSS7.3AI score0.02471EPSS
SaveExploits0References3
Check Point Advisories
Check Point Advisories
added 2015/04/14 12:00 a.m.47 views

ESF pfSense status_captiveportal Cross Site Scripting (CVE-2015-2294)

A cross-site scripting vulnerability has been reported in Electric Sheep Fencing pfSense firewall. The vulnerability is due to insufficient validation of the zone variable in the statuscaptiveportal page. A remote attacker can exploit the XSS vulnerability to execute arbitrary scripts in the user...

4.3CVSS2.5AI score0.24009EPSS
SaveExploits5
CNVD
CNVD
added 2015/04/07 12:00 a.m.15 views

Schneider Electric VAMPSET Buffer Overflow Vulnerability

Schneider Electric VAMPSET is a suite of software from Schneider Electric, France, deployed in the energy industry to configure and maintain multiple relays and arc monitors. A buffer overflow vulnerability exists in Schneider Electric VAMPSET version 2.2.145 and earlier. A local attacker can...

4.4CVSS7.5AI score0.00518EPSS
SaveExploits1References1
NVD
NVD
added 2015/04/03 10:59 a.m.36 views

CVE-2014-8390

Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a 1 CFG or 2 DAT file...

4.4CVSS6.6AI score0.00518EPSS
SaveExploits1References5
Prion
Prion
added 2015/04/03 10:59 a.m.24 views

Buffer overflow

Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a 1 CFG or 2 DAT file...

4.4CVSS7.2AI score0.00518EPSS
SaveExploits1References5Affected Software1
CVE
CVE
added 2015/04/03 10:00 a.m.65 views

CVE-2014-8390

Schneider Electric VAMPSET software (Schneider Electric VAMPSET) is affected by CVE-2014-8390. A stack-based and a heap-based buffer overflow can be triggered by opening specially crafted COMTRADE disturbance-recording files (CFG/DAT) in vulnerable versions, allowing local privilege escalation. E...

4.4CVSS6.7AI score0.00518EPSS
SaveExploits1References5Affected Software1
Cvelist
Cvelist
added 2015/04/03 10:00 a.m.48 views

CVE-2014-8390

Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a 1 CFG or 2 DAT file...

6.6AI score0.00518EPSS
SaveExploits1References5
Rows per page
Query Builder