added 2016/08/03 12:00 a.m.8 views

Schneider Electric PowerLogic PM8ECC Module Unauthorized Access Vulnerability

The Schneider Electric PowerLogic PM8ECC is a communication module for use in 800 series meters from Schneider Electric, France. An unauthorized access vulnerability exists in the Schneider Electric PowerLogic PM8ECC module that could be exploited by an attacker to gain full privileges to the web...

7AI score
SaveExploits0
seebug.org
seebug.org
added 2016/07/28 12:00 a.m.33 views

Schneider Electric PowerLogic PM8ECC XSS vulnerability

No description provided by source...

7.1AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2016/07/26 12:00 a.m.8 views

Schneider Electric GP-Pro EX ParseAPI Heap Buffer Overflow

A heap buffer overflow vulnerability exists in Schneider Electric GP-Pro EX. This is due to input validation errors when parsing project files. A remote attacker could exploit this vulnerability by enticing a user to open a specially crafted project file...

4.5AI score
SaveExploits0
ICS
ICS
added 2016/07/22 6:00 a.m.66 views

Schneider Electric PowerLogic PM8ECC Hard-coded Password Vulnerability

OVERVIEW Independent researcher He Congwen has identified a hard-coded password vulnerability in Schneider Electric’s PowerLogic PM8ECC device. Schneider Electric has produced a patch to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS The following...

9.8CVSS9.6AI score0.01944EPSS
SaveExploits0References10
Zero Day Initiative
Zero Day Initiative
added 2016/07/20 12:00 a.m.54 views

Schneider Electric SoMachine HVAC AxEditGrid ActiveX Control SetDataIntf Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric SoMachine HVAC. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists withi...

7.5CVSS2.5AI score0.04989EPSS
SaveExploits0References1
CNVD
CNVD
added 2016/07/20 12:00 a.m.12 views

Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers Arbitrary Code Execution Vulnerability

Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers is a set of programming software for M171/M172 controllers from Schneider Electric France. A security vulnerability exists in the ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M17...

7.5CVSS7.5AI score0.04989EPSS
SaveExploits0References1
CNVD
CNVD
added 2016/07/19 12:00 a.m.4 views

Multiple Vulnerabilities in Schneider Electric Automation Server Series

Schneider Electric Automation Server is a multifunctional automation deployment server from Schneider Electric France. Schneider Electric Automation Server Series 1.7 and earlier versions contain a security bypass vulnerability, an operating system command injection vulnerability, and a privilege...

8.1AI score
SaveExploits0References1
CNVD
CNVD
added 2016/07/18 12:00 a.m.13 views

Unspecified Vulnerability in Schneider Electric Pelco Digital Sentry Video Management System

Schneider Electric Pelco Digital Sentry Video Management System is a video recording system from Schneider Electric France. A security vulnerability exists in the Schneider Electric Pelco Digital Sentry Video Management System using firmware prior to version 7.13, which stems from the program's u...

10CVSS7.7AI score0.0579EPSS
SaveExploits0References1
NVD
NVD
added 2016/07/15 4:59 p.m.23 views

CVE-2016-5787

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

6.3CVSS6.1AI score0.00394EPSS
SaveExploits0References3
NVD
NVD
added 2016/07/15 4:59 p.m.31 views

CVE-2016-4529

An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFEFORUNTRUSTEDCALLER aka safe for scripting flag...

7.5CVSS7.6AI score0.04989EPSS
SaveExploits0References4
OSV
OSV
added 2016/07/15 4:59 p.m.13 views

CVE-2016-4529

An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFEFORUNTRUSTEDCALLER aka safe for scripting flag...

7.3CVSS6.1AI score0.04989EPSS
SaveExploits0References4
NVD
NVD
added 2016/07/15 4:59 p.m.23 views

CVE-2016-4520

Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors...

10CVSS9.7AI score0.0579EPSS
SaveExploits0References3
Prion
Prion
added 2016/07/15 4:59 p.m.26 views

Design/Logic Flaw

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

4.6CVSS6.7AI score0.00394EPSS
SaveExploits0References3Affected Software1
Prion
Prion
added 2016/07/15 4:59 p.m.23 views

Design/Logic Flaw

An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFEFORUNTRUSTEDCALLER aka safe for scripting flag...

7.5CVSS8.3AI score0.04989EPSS
SaveExploits0References4Affected Software1
Prion
Prion
added 2016/07/15 4:59 p.m.23 views

Hardcoded credentials

Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors...

10CVSS7.9AI score0.0579EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2016/07/15 4:00 p.m.38 views

CVE-2016-4520

Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors...

9.7AI score0.0579EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2016/07/15 4:00 p.m.46 views

CVE-2016-4529

An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFEFORUNTRUSTEDCALLER aka safe for scripting flag...

7.6AI score0.04989EPSS
SaveExploits0References4
CVE
CVE
added 2016/07/15 4:00 p.m.85 views

CVE-2016-4529

Schneider Electric SoMachine HVAC programming software for M171/M172 Controllers contains an unsafe ActiveX control (AxEditGrid) with a SetDataIntf dereference vulnerability. The flaw allows remote code execution via an attacker-supplied memory address in the untrusted pointer dereference within ...

7.5CVSS7.6AI score0.04989EPSS
SaveExploits0References4Affected Software1
CVE
CVE
added 2016/07/15 4:00 p.m.60 views

CVE-2016-4520

CVE-2016-4520 affects Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14, which contains hard-coded credentials that may allow remote attackers to gain access and, consequently, execute arbitrary code. The vulnerability is exploitable remotely over the netwo...

10CVSS9.4AI score0.0579EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2016/07/15 4:00 p.m.30 views

CVE-2016-5787

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

6.1AI score0.00394EPSS
SaveExploits0References3
Rows per page