9 matches found
Eaton Network Shutdown Module 3.21 PHP Code Injection
!/usr/bin/env python Quick 'n' Dirty - Metasploit module didn't do it for me 2013 - Filip Waeytens - http://www.wsec.be Usage Example: $ python eaton.py 192.168.1.9 "net user" User accounts for \ ------------------------------------------------------------------------------- Guest LocalAdmin The...
Eaton Network Shutdown Module 3.21 PHP Code Injection
Eaton Network Shutdown module versions 3.21 and below suffer from a remote PHP code injection vulnerability. This is a python exploit for a previously disclosed finding. !/usr/bin/env python Quick 'n' Dirty - Metasploit module didn't do it for me 2013 - Filip Waeytens - http://www.wsec.be Usage...
Eaton Network Shutdown Module 3.21 - Remote PHP Code Injection
Eaton Network Shutdown Module 3.21 - Remote PHP Code Injection !/usr/bin/env python Quick 'n' Dirty - Metasploit module didn't do it for me 2013 - Filip Waeytens - http://www.wsec.be Usage Example: $ python eaton.py 192.168.1.9 "net user" User accounts for \...
Eaton Network Shutdown Module 3.21 - Remote PHP Code Injection
!/usr/bin/env python Quick 'n' Dirty - Metasploit module didn't do it for me 2013 - Filip Waeytens - http://www.wsec.be Usage Example: $ python eaton.py 192.168.1.9 "net user" User accounts for \ ------------------------------------------------------------------------------- Guest LocalAdmin The...
Eaton Network Shutdown Module Arbitrary PHP Code Execution Vulnerability
Eaton Network Shutdown Module is prone to a remote PHP code-execution vulnerability. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if...
Eaton Network Shutdown Module Detection
The remote web server is part of Network Shutdown Module, from Eaton Corporation formerly MGE Office Protection Systems. It is used to monitor UPS-protected computers and shut them down gracefully if AC power fails. C Tenable Network Security, Inc. include"compat.inc"; if description scriptid6008...
Eaton Network Shutdown Module Default Administrator Credentials
The remote Eaton Network Shutdown Module install uses a default set of credentials to control access to its administrative functionality. With this information, an attacker can gain complete access to the application. %NASLMINLEVEL 70300 C Tenable Network Security, Inc...
Eaton Network Shutdown Module view_list.php paneStatusListSortBy Parameter eval() Call Remote PHP Code Execution
The version of the Eaton Network Shutdown Module hosted on the remote web server does not sanitize user input to the 'paneStatusListSortBy' parameter of the 'viewlist.php' script before using it as part of a command to be executed via PHP's 'eval' function. An unauthenticated, remote attacker can...
Eaton Network Shutdown Module < 3.20 Authentication Bypass / Command Execution
According to its version number, the Network Shutdown Module install on the remote host is earlier than 3.20. It therefore reportedly fails to require authentication before allowing a remote attacker to add custom actions through the 'paneactionbutton.php' script and then execute them via the...