Lucene search
+L

92 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•4 views

CVE-2024-25138: Plaintext Storage of a Password

In AutomationDirect C-MORE EA9 HMI, credentials used by the platform are stored as plain text on the device...

6.5CVSS5.8AI score0.00399EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•2 views

CVE-2024-25137: Stack-based Buffer Overflow

In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-service conditions...

4.3CVSS6.2AI score0.0045EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•5 views

CVE-2024-25136: Improper Limitation of a Pathname to a Restricted Directory

There is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without proper sanitizing of the content...

7.5CVSS5.8AI score0.00618EPSS
SaveExploits0References2
NVD
NVD
•added 2022/08/31 4:15 p.m.•39 views

CVE-2022-2006

AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to...

7.8CVSS0.00356EPSS
SaveExploits0References1
NVD
NVD
•added 2022/08/31 4:15 p.m.•29 views

CVE-2022-2005

AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73;...

7.5CVSS0.00524EPSS
SaveExploits0References1
Prion
Prion
•added 2022/08/31 4:15 p.m.•28 views

Code injection

AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73;...

5CVSS7.3AI score0.00524EPSS
SaveExploits0References1Affected Software12
Prion
Prion
•added 2022/08/31 4:15 p.m.•34 views

Code injection

AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to...

4.4CVSS7.6AI score0.00356EPSS
SaveExploits0References1Affected Software12
Cvelist
Cvelist
•added 2022/08/31 3:33 p.m.•35 views

CVE-2022-2005 AutomationDirect C-more EA9 HMI Cleartext Transmission

AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73;...

7.5CVSS7.6AI score0.00524EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2022/08/31 3:33 p.m.•49 views

CVE-2022-2006 AutomationDirect C-more EA9 HMI Uncontrolled Search Path Element

AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to...

7.8CVSS7.8AI score0.00356EPSS
SaveExploits0References1
CVE
CVE
•added 2022/08/31 3:33 p.m.•73 views

CVE-2022-2005

AutomationDirect C-more EA9 HMI contains a vulnerability in its HTTP webserver that transmits credentials in an insecure, cleartext-like mechanism. Affected products include EA9-T6CL/6CL-R, T7CL/7CL-R, T8CL, T10CL/T10WCL, T12CL, T15CL/T15CL-R, RHMI, PGMSW prior to firmware 6.73. Exploitation coul...

7.5CVSS7.4AI score0.00524EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2022/08/31 3:33 p.m.•25 views

CVE-2022-2006 AutomationDirect C-more EA9 HMI Uncontrolled Search Path Element

AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to...

7.8CVSS7.7AI score0.00356EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/08/31 12:00 a.m.•7 views

CVE-2022-2005: Cleartext Transmission of Sensitive Information

AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73;...

7.5CVSS7.2AI score0.00524EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2022/07/22 12:00 a.m.•15 views

多款AutomationDirect产品安全漏洞

AutomationDirect C-more EA9 HMI and so on are products of AutomationDirect, Inc.AutomationDirect C-more EA9 HMI is a series of touch screen panels.AutomationDirect DirectLOGIC is a programmable logic AutomationDirect SIO-MB04RTDS is a programmable logic controller. A security vulnerability exists...

9.6CVSS7.3AI score0.00522EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
•added 2022/07/13 12:00 a.m.•16 views

The vulnerability of the DLL library of the Microprogramming Software for Sensor Panels from AutomationDirect C-More series EA9 HMI allows a hacker to execute arbitrary code during the installation process.

The vulnerability of the DLL library of C-More sensor panel microprogramming systems series EA9 HMI is related to an uncontrolled search path element. Exploiting this vulnerability could allow a attacker to execute arbitrary code during the installation process...

7.8CVSS7.6AI score0.00356EPSS
SaveExploits0References3Affected Software12
Positive Technologies
Positive Technologies
•added 2022/06/16 12:00 a.m.•20 views

PT-2022-3487 · Automationdirect · C-More Ea9

Name of the Vulnerable Software and Affected Versions: AutomationDirect C-more EA9 versions prior to 6.73 Description: The issue is related to the insecure mechanism used by the AutomationDirect C-more EA9 HTTP webserver to transport credentials from the client to the web server. This may allow a...

7.8CVSS7.3AI score0.00524EPSS
SaveExploits0References3
OSV
OSV
•added 2020/07/23 4:15 p.m.•15 views

CVE-2020-10922

This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issu...

7.5CVSS5.8AI score
SaveExploits0References1
OSV
OSV
•added 2020/07/23 4:15 p.m.•15 views

CVE-2020-10921

This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lac...

9.8CVSS7.4AI score0.02808EPSS
SaveExploits0References1
NVD
NVD
•added 2020/07/23 4:15 p.m.•39 views

CVE-2020-10921

This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lac...

9.8CVSS9.7AI score0.02808EPSS
SaveExploits0References1
NVD
NVD
•added 2020/07/23 4:15 p.m.•43 views

CVE-2020-10922

This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issu...

7.5CVSS7.5AI score0.03674EPSS
SaveExploits0References1
NVD
NVD
•added 2020/07/23 4:15 p.m.•38 views

CVE-2020-10918

This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due t...

7.5CVSS7.8AI score0.02728EPSS
SaveExploits0References1
Rows per page
Query Builder