Lucene search
K

8 matches found

EUVD
EUVD
added 2025/10/03 8:7 p.m.3 views

EUVD-2025-7153

Malicious code in bioql PyPI...

9.8CVSS6.6AI score0.00517EPSS
Exploits0References3
RedhatCVE
RedhatCVE
added 2025/03/22 7:24 p.m.13 views

CVE-2025-29980

A SQL injection issue has been discovered in eTRAKiT.net release 3.2.1.77. Due to improper input validation, a remote unauthenticated attacker can run arbitrary commands as the current MS SQL server account. It is recommended that the CRM feature is turned off while on eTRAKiT.net release 3.2.1.7...

9.8CVSS8.7AI score0.00517EPSS
Exploits0References4
NVD
NVD
added 2025/03/20 7:15 p.m.8 views

CVE-2025-29980

A SQL injection issue has been discovered in eTRAKiT.net release 3.2.1.77. Due to improper input validation, a remote unauthenticated attacker can run arbitrary commands as the current MS SQL server account. It is recommended that the CRM feature is turned off while on eTRAKiT.net release 3.2.1.7...

9.8CVSS0.00517EPSS
Exploits0References2
OSV
OSV
added 2025/03/20 7:15 p.m.1 views

CVE-2025-29980

A SQL injection issue has been discovered in eTRAKiT.net release 3.2.1.77. Due to improper input validation, a remote unauthenticated attacker can run arbitrary commands as the current MS SQL server account. It is recommended that the CRM feature is turned off while on eTRAKiT.net release 3.2.1.7...

9.3CVSS5.9AI score
Exploits0References2
Vulnrichment
Vulnrichment
added 2025/03/20 7:3 p.m.8 views

CVE-2025-29980 Blind SQL Injection vulnerability in eTRAKiT.Net

A SQL injection issue has been discovered in eTRAKiT.net release 3.2.1.77. Due to improper input validation, a remote unauthenticated attacker can run arbitrary commands as the current MS SQL server account. It is recommended that the CRM feature is turned off while on eTRAKiT.net release 3.2.1.7...

9.8CVSS10AI score0.00517EPSS
Exploits0References2
CVE
CVE
added 2025/03/20 7:3 p.m.57 views

CVE-2025-29980

CVE-2025-29980 affects CentralSquare eTRAKiT.net 3.2.1.77, where an SQL injection due to improper input validation in the CRM feature allows a remote, unauthenticated attacker to run arbitrary commands as the current Microsoft SQL Server account. Impact is rated CRITICAL (CVSS v3.1: AV:N/AC:L/PR:...

9.8CVSS10AI score0.00517EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2025/03/20 7:3 p.m.9 views

CVE-2025-29980 Blind SQL Injection vulnerability in eTRAKiT.Net

A SQL injection issue has been discovered in eTRAKiT.net release 3.2.1.77. Due to improper input validation, a remote unauthenticated attacker can run arbitrary commands as the current MS SQL server account. It is recommended that the CRM feature is turned off while on eTRAKiT.net release 3.2.1.7...

9.8CVSS0.00517EPSS
Exploits0References2
ICS
ICS
added 2025/03/20 12:0 a.m.6 views

CentralSquare eTRAKiT.Net SQL injection vulnerability

RISK EVALUATION eTRAKiT is a public online portal that provides the public with easily accessible information related to permits, projects, licenses, code compliance, land, and inspections. An SQL injection vulnerability in the CRM feature of eTRAKiT.net release 3.2.1.77 allows a remote,...

9.8CVSS8.3AI score0.00517EPSS
Exploits0References1
Rows per page