74 matches found
Design/Logic Flaw
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users...
Session fixation
Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...
CVE-2018-8848
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...
CVE-2018-8842
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to...
CVE-2018-8848
Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-8848 due to incorrect default permissions that expose an object to an unintended actor. This CVE is categorized under CWE-276 (Incorrect Default Permissions). The issue was observed during installation and ...
CVE-2018-8850
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result ...
CVE-2018-8848
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...
CVE-2018-8856
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...
CVE-2018-8846
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users...
CVE-2018-14803
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to t...
CVE-2018-8844
Philips e-Alert Unit (non‑medical device), Version R2.1 and prior, contains a Cross‑Site Request Forgery (CSRF) weakness in which the web application does not sufficiently verify that a user’s request is intentional. This CSRF issue could allow an attacker to perform unauthorized operations when ...
CVE-2018-8854
CVE-2018-8854 affects Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The issue is Uncontrolled Resource Consumption (Resource Exhaustion): the software does not properly restrict the size/amount of resources requested, allowing an attacker to consume resources. Affects Philips...
CVE-2018-8852
Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-8852 (session fixation). When authenticating or establishing a new session, an attacker may steal authenticated sessions without invalidating existing session IDs, enabling session hijacking. Severity in CV...
CVE-2018-8850
Philips e-Alert Unit (non‑medical) Version R2.1 and prior is affected by CVE-2018-8850 due to improper input validation (CWE-20), which can cause unintended input, altered control flow, or arbitrary code execution. The vulnerability is documented with high to critical impact (NVD CVSS v3 base 9.8...
CVE-2018-8842
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to...
CVE-2018-14803
Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-14803 which describes an information-disclosure vulnerability: an attacker could obtain extraneous product information (e.g., OS/software components) via HTTP response headers that are normally not exposed....
CVE-2018-8852
Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...
CVE-2018-8844
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...
CVE-2018-8856
This CVE affects Philips e-Alert Unit (non-medical device), Versions R2.1 and prior. The issue is the use of a hard-coded cryptographic key for internal data encryption (CWE-798), which enables high-severity impact. Per the connected docs, CVSS v3 base score is 9.8 (critical) with remote/network ...
CVE-2018-8854
Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended...