Lucene search
K

46 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2018-20462

Malware in sbrugna...

7.5CVSS7.8AI score0.01345EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2018-20464

Malware in sbrugna...

9.8CVSS9.5AI score0.00366EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2018-20460

Malware in sbrugna...

8.8CVSS8.8AI score0.00635EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2018-20452

Malware in sbrugna...

8.8CVSS8.8AI score0.00149EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2018-20458

Malware in sbrugna...

9.8CVSS9.5AI score0.02264EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2018-20450

Malware in sbrugna...

8.8CVSS8.8AI score0.00413EPSS
Exploits0References4
NVD
NVD
added 2018/09/26 7:29 p.m.9 views

CVE-2018-8856

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...

9.8CVSS8.1AI score0.00366EPSS
Exploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.1 views

CVE-2018-8856

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...

9.8CVSS5.8AI score
Exploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.9 views

CVE-2018-8854

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended...

7.5CVSS7.4AI score0.01345EPSS
Exploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.8 views

CVE-2018-8850

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result ...

9.8CVSS8.2AI score0.02264EPSS
Exploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.8 views

CVE-2018-8852

Philips e-Alert Unit non-medical device, Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier...

8.8CVSS7.7AI score0.00635EPSS
Exploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.2 views

CVE-2018-8850

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result ...

9.8CVSS6AI score
Exploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.8 views

CVE-2018-8846

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users...

6.1CVSS6.2AI score0.00345EPSS
Exploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.3 views

CVE-2018-8844

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.8CVSS5.8AI score
Exploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.1 views

CVE-2018-8848

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

7.5CVSS5.8AI score0.00565EPSS
Exploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.9 views

CVE-2018-8848

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

7.5CVSS7.5AI score0.00565EPSS
Exploits0References3
NVD
NVD
added 2018/09/26 7:29 p.m.11 views

CVE-2018-8844

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.8CVSS7.8AI score0.00149EPSS
Exploits0References3
OSV
OSV
added 2018/09/26 7:29 p.m.1 views

CVE-2018-8846

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users...

6.1CVSS5.8AI score0.00345EPSS
Exploits0References3
ATTACKERKB
ATTACKERKB
added 2018/09/26 7:29 p.m.1 views

CVE-2018-8856

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data...

9.8CVSS5.4AI score0.00366EPSS
Exploits0References4
Prion
Prion
added 2018/09/26 7:29 p.m.9 views

Code injection

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

5CVSS7.9AI score0.00565EPSS
Exploits0References3Affected Software1