Lucene search
+L

18 matches found

RedhatCVE
RedhatCVE
•added 2026/05/07 8:21 p.m.•21 views

CVE-2026-8033

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit ha...

6.9CVSS5.5AI score0.00483EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2026/05/07 8:21 p.m.•19 views

CVE-2026-8032

A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMINKEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has...

7.5CVSS6.8AI score0.00472EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/05/06 9:31 p.m.•18 views

EUVD-2026-28203

A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMINKEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has...

7.5CVSS5.5AI score0.00472EPSS
SaveExploits0References5
Vulnrichment
Vulnrichment
•added 2026/05/06 7:30 p.m.•10 views

CVE-2026-8033 PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit ha...

6.9CVSS5.2AI score0.00483EPSS
SaveExploits0References4
NVD
NVD
•added 2026/05/06 7:16 p.m.•19 views

CVE-2026-8031

A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The...

6.9CVSS0.00675EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2026/05/06 7:00 p.m.•42 views

CVE-2026-8032 PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials

A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMINKEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has...

7.5CVSS0.00472EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2026/05/06 7:00 p.m.•12 views

CVE-2026-8032 PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials

A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMINKEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has...

7.5CVSS6.8AI score0.00472EPSS
SaveExploits0References4
CVE
CVE
•added 2026/05/06 7:00 p.m.•25 views

CVE-2026-8032

CVE-2026-8032 affects PicoTronica e-Clinic Healthcare System ECHS (v5.7). In echs.js (path: /cdemos/echs/priv/echs.js), an argument manipulation of ADMIN_KEY leads to hard-coded credentials exposed in the remote-access component. The issue enables remote exploitation with a published exploit; imp...

7.5CVSS6.8AI score0.00472EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2026/05/06 6:00 p.m.•14 views

CVE-2026-8031 PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication

A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The...

6.9CVSS5.8AI score0.00675EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2026/05/06 12:00 a.m.•37 views

PT-2026-38216

Name of the Vulnerable Software and Affected Versions PicoTronica e-Clinic Healthcare System ECHS version 5.7 Description A missing authentication flaw exists in the API Endpoint component within the file '/cdemos/echs/api/v2/patient-records'. This issue allows a remote attacker to bypass...

6.9CVSS6.1AI score0.00675EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2026/05/06 12:00 a.m.•34 views

PT-2026-38225

Name of the Vulnerable Software and Affected Versions PicoTronica e-Clinic Healthcare System ECHS version 5.7 Description An issue in the Response Header Handler component within the file '/cdemos/echs/api/v2/' allows for remote information disclosure. Recommendations Upgrade to version 5.7.1...

6.9CVSS6.1AI score0.00483EPSS
SaveExploits0References6
CNNVD
CNNVD
•added 2026/05/06 12:00 a.m.•22 views

PicoTronica e-Clinic Healthcare System ECHS 安全漏洞

PicoTronica e-Clinic Healthcare System ECHS is a medical clinic management system developed by the British company PicoTronica. Version 5.7 of the PicoTronica e-Clinic Healthcare System ECHS contains a security vulnerability. This vulnerability stems from an issue with the parameter ADMINKEY in t...

7.5CVSS7.1AI score0.00472EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/06 12:00 a.m.•3 views

CVE-2026-8031: Missing Authentication for Critical Function

A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The...

6.9CVSS5.3AI score0.00675EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2026/05/06 12:00 a.m.•20 views

PicoTronica e-Clinic Healthcare System ECHS 信息泄露漏洞

PicoTronica e-Clinic Healthcare System ECHS is a medical clinic management system developed by the British company PicoTronica. Version 5.7 of the PicoTronica e-Clinic Healthcare System ECHS contains a vulnerability related to information leakage. This vulnerability stems from an unknown function...

6.9CVSS6AI score0.00483EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/05/06 12:00 a.m.•29 views

PT-2026-38224

Name of the Vulnerable Software and Affected Versions PicoTronica e-Clinic Healthcare System ECHS version 5.7 Description A flaw in the file /cdemos/echs/priv/echs.js allows remote attackers to exploit hard-coded credentials through the manipulation of the ADMIN KEY argument. Recommendations...

7.5CVSS5.7AI score0.00472EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/06 12:00 a.m.•1 views

CVE-2026-8032: Use of Hard-coded Credentials

A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMINKEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has...

7.5CVSS5.3AI score0.00472EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/06 12:00 a.m.•1 views

CVE-2026-8033: Exposure of Sensitive Information to an Unauthorized Actor

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit ha...

6.9CVSS5.1AI score0.00483EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2026/05/06 12:00 a.m.•19 views

PicoTronica e-Clinic Healthcare System ECHS 授权问题漏洞

PicoTronica e-Clinic Healthcare System ECHS is a medical clinic management system developed by the British company PicoTronica. Version 5.7 of the PicoTronica e-Clinic Healthcare System ECHS contains an authorization vulnerability. This vulnerability stems from an unknown function in the API...

6.9CVSS6AI score0.00675EPSS
SaveExploits0References1
Rows per page
Query Builder