Lucene search
K

40 matches found

ATTACKERKB
ATTACKERKB
added 2 days ago4 views

CVE-2019-25720

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score0.00024EPSS
Exploits0References3
Cvelist
Cvelist
added 2 days ago34 views

CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS0.00024EPSS
Exploits0References2
EUVD
EUVD
added 2 days ago7 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References3
NVD
NVD
added 3 days ago8 views

CVE-2025-15653

Dräger Zeus Infinity Empowered Zeus IE and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB interface manipulation. Attackers can exploit the unprotected USB interfaces to...

7CVSS0.00022EPSS
Exploits0References2
NVD
NVD
added 3 days ago11 views

CVE-2021-4481

Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges. Attackers can replace binaries or loaded modules on the host system to execu...

8.3CVSS0.00015EPSS
Exploits0References2
NVD
NVD
added 3 days ago9 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.00045EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 3 days ago5 views

CVE-2021-4480

Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges. Attackers can replace binaries or loaded modules on the host system to execu...

8.3CVSS6.2AI score0.00015EPSS
Exploits0References3
ATTACKERKB
ATTACKERKB
added 3 days ago6 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References3
CVE
CVE
added 3 days ago11 views

CVE-2021-4479

Dräger Atlan A350 vulnerable software versions 1.00–1.01 due to improper input handling in the Medibus interface. An attacker can send crafted non‑Medibus‑compliant data to trigger a denial of service by overloading the internal processor, potentially causing device operation disruption over seve...

6.3CVSS5.8AI score0.00043EPSS
Exploits0References2
Cvelist
Cvelist
added 3 days ago27 views

CVE-2021-4479 Dräger Atlan A350 1.00-1.01 DoS via Medibus Interface

Dräger Atlan A350 software versions 1.00 through 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed data to overload th...

6.3CVSS0.00043EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 3 days ago5 views

CVE-2019-25723

Dräger Perseus A500 software versions 2.00 through 2.02 contains an improper input handling vulnerability that allows external attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can overload the internal...

6.3CVSS5.8AI score0.00043EPSS
Exploits0References3Affected Software1
CVE
CVE
added 3 days ago7 views

CVE-2019-25723

CVE-2019-25723 describes an improper input handling vulnerability in Dräger Perseus A500 software 2.00–2.02 . An external attacker can cause a DoS by sending specially crafted, non-Medibus‑compliant data through the Medibus interface , flooding the internal processor and triggering a warm restart...

6.3CVSS5.8AI score0.00043EPSS
Exploits0References2
CVE
CVE
added 3 days ago8 views

CVE-2019-25722

The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...

7.6CVSS5.9AI score0.00043EPSS
Exploits0References2
Cvelist
Cvelist
added 3 days ago25 views

CVE-2019-25721 Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00016EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 3 days ago4 views

CVE-2019-25721 Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
EUVD
EUVD
added 3 days ago5 views

EUVD-2019-20157

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
EUVD
EUVD
added 3 days ago5 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 3 days ago5 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References4
EUVD
EUVD
added 3 days ago3 views

EUVD-2019-20155

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS5.8AI score0.00012EPSS
Exploits0References2
CVE
CVE
added 3 days ago8 views

CVE-2019-25717

CVE-2019-25717 affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. The vulnerability allows unauthenticated attackers over a network to access exposed log files, exposing device internals, location data, and wired network configuration details. No root cause or remediation detail...

5.3CVSS5.8AI score0.00012EPSS
Exploits0References2
Rows per page
Query Builder