382 matches found
Siemens En100 Improper Authentication
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens Siprotec Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens Dnp3 Improper Input Validation
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
Siemens Dnp3 Improper Input Validation
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
Siemens En100 Missing Authentication for Critical Function
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module DNP3 variant All versions V1.04, EN100 Ethernet module PROFINET IO variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module IEC 104...
Siemens En100 Improper Authentication
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens Siprotec Unspecified Vulnerability
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Rockwell Automation/Allen-Bradley MicroLogix 1400 Series A <= 7 and Series B <= 15.000 DNP3 Remote DoS
Binary data 64.prm...
Siemens CP 1243-1 DNP3 Detection
Binary data 750159.prm...
Schneider Electric X80 RTU Detection
Binary data 762309.prm...
GE IC695EDM001 PACSystems RX3i DNP3 Ethernet Master Detection
Binary data 755488.prm...
Schneider Electric X80 RTU Detection
Binary data 762308.prm...
GE IC695EDS001 PACSystems RX3i DNP3 Ethernet Outstation Detection
Binary data 755489.prm...
CVE-2018-16563
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...
CVE-2018-16563
Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays are affected by CVE-2018-16563 due to improper input validation. Specially crafted packets sent to TCP port 102 can cause a denial-of-service, requiring a manual restart to restore EN100 module functionality. Exploitation requires ...
DNP3 Detection of Device attributes
Binary data scadadnp3devicedetect.nbin...
DNP3 Implementation Vulnerability (Update B)
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-13-291-01A DNP3 Implementation Vulnerability that was published November 21, 2013, on the NCCIC/ICS-CERT web site. Adam Crain of Automatak and Chris Sistrunk, Sr. Consultant for Mandiant, reported an improper input...
CVE-2018-11451
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
Design/Logic Flaw
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
CVE-2018-11452
CVE-2018-11452 affects Siemens EN100 Ethernet Module firmware variants (IEC 61850, PROFINET IO, Modbus TCP, DNP3 TCP, IEC104). The root cause is an improper handling of crafted packets to port 102/TCP that can trigger a Denial-of-Service condition when oscillographs are running, compromising avai...