Lucene search
K

11 matches found

RedhatCVE
RedhatCVE
added 2026/01/09 9:53 a.m.3 views

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.8CVSS8AI score0.09013EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-3061

Malware in sbrugna...

7.5CVSS7.5AI score0.00697EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.4 views

EUVD-2020-3059

Malware in sbrugna...

9.8CVSS9.2AI score0.09013EPSS
Exploits0References3
RedhatCVE
RedhatCVE
added 2025/05/22 4:7 p.m.3 views

CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...

7.5CVSS6.5AI score0.00697EPSS
Exploits0References1
NVD
NVD
added 2020/04/15 7:15 p.m.9 views

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.8CVSS9.8AI score0.09013EPSS
Exploits0References2
Prion
Prion
added 2020/04/15 7:15 p.m.7 views

Type confusion

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

7.5CVSS9.8AI score0.09013EPSS
Exploits0References2Affected Software1
Prion
Prion
added 2020/04/15 7:15 p.m.7 views

Design/Logic Flaw

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...

5CVSS7.4AI score0.00697EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2020/04/15 6:36 p.m.14 views

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.7AI score0.09013EPSS
Exploits0References2
CVE
CVE
added 2020/04/15 6:36 p.m.52 views

CVE-2020-10611

CVE-2020-10611 is a real, externally exploitable type-confusion vulnerability in Triangle MicroWorks SCADA Data Gateway (DNP3 Data Sets). The Red Hat and NVD entries confirm it affects versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122, enabling remote code execution with no authentication required...

9.8CVSS9.7AI score0.09013EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2020/04/15 6:30 p.m.41 views

CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway is affected by CVE-2020-10613 (and related CVEs) in versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122 due to an out-of-bounds read from improper validation of user-supplied data in DNP3 Data Sets. The vulnerability allows remote attackers to disclose sensitiv...

7.5CVSS7.3AI score0.00697EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2020/04/15 6:30 p.m.13 views

CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...

7.3AI score0.00697EPSS
Exploits0References2
Rows per page