Lucene search
K

15 matches found

RedhatCVE
RedhatCVE
added 2026/01/09 9:54 a.m.5 views

CVE-2020-12733

Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...

7.5CVSS7.2AI score0.00286EPSS
Exploits1References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-5020

Malware in sbrugna...

6.5CVSS6.5AI score0.00095EPSS
Exploits1References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2020-5021

Malware in sbrugna...

7.5CVSS7.5AI score0.00286EPSS
Exploits1References3
CNVD
CNVD
added 2021/07/16 12:0 a.m.18 views

Unspecified vulnerability in DEPSTECH WiFi Digital Microscope

DEPSTECH WiFi Digital Microscope is a wifi industrial endoscope from Shenzhen Shenhai Innovation Technology Co., Ltd. in China. DEPSTECH WiFi Digital Microscope 3 has a security vulnerability that allows remote attackers to change the SSID and password and demand a ransom from the legitimate devi...

8.1CVSS3.2AI score0.00345EPSS
Exploits1References1
CNVD
CNVD
added 2021/07/16 12:0 a.m.15 views

Unspecified vulnerability in DEPSTECH WiFi Digital Microscope (CNVD-2021-60544)

DEPSTECH WiFi Digital Microscope is a wifi industrial endoscope from Shenzhen Shenhai Innovation Technology Co., Ltd. in China. DEPSTECH WiFi Digital Microscope 3 has a security vulnerability that could be exploited by attackers to gain access to sensitive information...

6.5CVSS3.1AI score0.00095EPSS
Exploits1References1
NVD
NVD
added 2021/07/15 4:15 p.m.7 views

CVE-2020-12733

Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...

7.5CVSS0.00286EPSS
Exploits1References2
NVD
NVD
added 2021/07/15 4:15 p.m.8 views

CVE-2020-12734

DEPSTECH WiFi Digital Microscope 3 allows remote attackers to change the SSID and password, and demand a ransom payment from the rightful device owner, because there is no way to reset to Factory Default settings...

8.1CVSS0.00345EPSS
Exploits1References2
Prion
Prion
added 2021/07/15 4:15 p.m.15 views

Design/Logic Flaw

DEPSTECH WiFi Digital Microscope 3 allows remote attackers to change the SSID and password, and demand a ransom payment from the rightful device owner, because there is no way to reset to Factory Default settings...

4.8CVSS8AI score0.00345EPSS
Exploits1References2
Prion
Prion
added 2021/07/15 4:15 p.m.13 views

Design/Logic Flaw

Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...

5CVSS7.7AI score0.00286EPSS
Exploits1References2
CVE
CVE
added 2021/07/15 3:4 p.m.33 views

CVE-2020-12732

The CVE-2020-12732 entry concerns DEPSTECH WiFi Digital Microscope 3, which ships with a default SSID Jetion_xxxxxxxx and a default password 12345678. Multiple connected sources (Red Hat, CNVD, CVE lists, etc.) confirm a vulnerability tied to these default credentials enabling access to sensitive...

6.5CVSS6.5AI score0.00095EPSS
Exploits1References2Affected Software1
CVE
CVE
added 2021/07/15 3:4 p.m.36 views

CVE-2020-12733

Summary of CVE-2020-12733 : A vulnerability in DEPSTECH WiFi Digital Microscope 3 (uses Shenzhen PENGLIXIN components) allows a TELNET connection using the molinkadmin password for the molink account. Documented across multiple sources (NVD, Red Hat, CVE listings, CNNVD) with consistent descripti...

7.5CVSS7.6AI score0.00286EPSS
Exploits1References2Affected Software1
Cvelist
Cvelist
added 2021/07/15 3:4 p.m.13 views

CVE-2020-12733

Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...

7.7AI score0.00286EPSS
Exploits1References2
CVE
CVE
added 2021/07/15 3:3 p.m.33 views

CVE-2020-12734

DEPSTECH WiFi Digital Microscope 3 is affected. The vulnerability allows remote attackers to change the device’s SSID and password and potentially demand a ransom because there is no way to reset to Factory Default settings. The available documents describe the product and the insecure behavior b...

8.1CVSS8AI score0.00345EPSS
Exploits1References2Affected Software1
Cvelist
Cvelist
added 2021/07/15 3:3 p.m.11 views

CVE-2020-12734

DEPSTECH WiFi Digital Microscope 3 allows remote attackers to change the SSID and password, and demand a ransom payment from the rightful device owner, because there is no way to reset to Factory Default settings...

8.1AI score0.00345EPSS
Exploits1References2
CNNVD
CNNVD
added 2021/07/15 12:0 a.m.1 views

DEPSTECH WiFi Digital Microscope 安全漏洞

DEPSTECH WiFi Digital Microscope is a wifi industrial endoscope from Shenzhen Shenzhen Deepsea Innovation Technology Co. A security vulnerability exists in the DEPSTECH WiFi Digital Microscope 3, which stems from the device allowing TELNET connections using the molinkadmin password for the molink...

7.5CVSS7.3AI score0.00286EPSS
Exploits1References2