1767 matches found
CVE-2026-0827
During an internal security assessment, a potential vulnerability was discovered in Lenovo Diagnostics and the HardwareScanAddin used in Lenovo Vantage that, during installation or when using hardware scan, could allow a local authenticated user to perform an arbitrary file write with elevated...
CVE-2026-25787
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
CVE-2026-50211
Leftover engineering diagnostics and factory-level diagnostic software remain exposed on retail builds, giving malicious apps write privileges to internal NVRAM registers...
CVE-2026-9844
Use of default credentials vulnerability in Roche Diagnostics navify Digital Pathology RabbitMQ Management interface modules allows Default Usernames and Passwords. This issue affects navify Digital Pathology: from 2.0.0 before 2.4.1...
PT-2026-46988
Summary managementServer.CreateSchematic internal/backend/grpc/schematics.go passes the caller-controlled TalosVersion field directly to imageFactoryClient.OverlaysVersions, which embeds it verbatim into a fmt.Sprintf"/version/%s/overlays/official", talosVersion path template. url.URL.JoinPath...
EUVD-2026-34247
This vulnerability exists in GX Earth ONT models due to improper handling of user-supplied input in multiple diagnostic functions in its web management interface. An authenticated remote attacker could exploit this vulnerability by injecting arbitrary and executing OS commands on the targeted...
CVE-2026-45431
This vulnerability exists in GX Earth ONT models due to improper handling of user-supplied input in multiple diagnostic functions in its web management interface. An authenticated remote attacker could exploit this vulnerability by injecting arbitrary and executing OS commands on the targeted...
CVE-2026-50211
Leftover engineering diagnostics and factory-level diagnostic software remain exposed on retail builds, giving malicious apps write privileges to internal NVRAM registers...
CVE-2026-50211 Exposed Factory Testing App Boundaries
Leftover engineering diagnostics and factory-level diagnostic software remain exposed on retail builds, giving malicious apps write privileges to internal NVRAM registers...
CVE-2026-50211
Leftover engineering diagnostics and factory-level diagnostic software remain exposed on retail builds, giving malicious apps write privileges to internal NVRAM registers...
EUVD-2026-34223
Leftover engineering diagnostics and factory-level diagnostic software remain exposed on retail builds, giving malicious apps write privileges to internal NVRAM registers...
CVE-2026-50211 Exposed Factory Testing App Boundaries
Leftover engineering diagnostics and factory-level diagnostic software remain exposed on retail builds, giving malicious apps write privileges to internal NVRAM registers...
CVE-2026-50211
Technical details about CVE-2026-50211 are not publicly provided in the supplied documents. Monitor for updates as additional data may reveal affected products, root cause, and mitigations.
PT-2026-46194
This vulnerability exists in GX Earth ONT models due to improper handling of user-supplied input in multiple diagnostic functions in its web management interface. An authenticated remote attacker could exploit this vulnerability by injecting arbitrary and executing OS commands on the targeted...
PT-2026-46163
Name of the Vulnerable Software and Affected Versions Acer Connect M6E 5G Portable WiFi Router affected versions not specified Description Engineering diagnostics and factory-level diagnostic software are exposed on retail builds. This allows malicious applications to obtain write privileges to...
VMware NSX SD-WAN Edge - Command Injection
VMware NSX SD-WAN Edge formerly VeloCloud Edge before 3.1.2 contains an unauthenticated command injection in the local web UI diagnostic tools Ping/Traceroute. This template detects it reliably by injecting 'id', 'whoami', and a random marker. id: CVE-2018-6961 info: name: VMware NSX SD-WAN Edge ...
CVE-2026-9844
Use of default credentials vulnerability in Roche Diagnostics navify Digital Pathology RabbitMQ Management interface modules allows Default Usernames and Passwords. This issue affects navify Digital Pathology: from 2.0.0 before 2.4.1...
GHSA-9G8X-92Q2-P28F NodeVM observability builtins leak host process and HTTP request data
Summary NodeVM exposes some process-wide observability builtins when they are allowed through require.builtin. The following builtins are not blocked by the dangerous builtin denylist: text diagnosticschannel asynchooks perfhooks These modules are process-wide, not sandbox-local. Sandboxed code c...
NodeVM observability builtins leak host process and HTTP request data
Summary NodeVM exposes some process-wide observability builtins when they are allowed through require.builtin. The following builtins are not blocked by the dangerous builtin denylist: text diagnosticschannel asynchooks perfhooks These modules are process-wide, not sandbox-local. Sandboxed code c...
Incomplete List of Disallowed Inputs
Overview vm2 is a sandbox that can run untrusted code with whitelisted Node's built-in modules. Affected versions of this package are vulnerable to Incomplete List of Disallowed Inputs via the NodeVM builtin allowlist in lib/builtin.js. An attacker can read host-process state by supplying a sandb...