22 matches found
EUVD-2026-29427
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
CVE-2026-25787
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
CVE-2026-25787
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
EUVD-2018-18145
Malware in sbrugna...
EUVD-2025-18999
Malicious code in bioql PyPI...
CVE-2025-41427
WRC-X3000GS, WRC-X3000GSA, and WRC-X3000GSN contain an improper neutralization of special elements used in an OS command 'OS Command Injection' vulnerability in Connection Diagnostics page. If a remote authenticated attacker sends a specially crafted request to the affected product, an arbitrary ...
CVE-2024-42756
An issue in Netgear DGN1000WW v.1.1.00.45 allows a remote attacker to execute arbitrary code via the Diagnostics page...
CVE-2024-42756
An issue in Netgear DGN1000WW v.1.1.00.45 allows a remote attacker to execute arbitrary code via the Diagnostics page...
CVE-2024-42756
An issue in Netgear DGN1000WW v.1.1.00.45 allows a remote attacker to execute arbitrary code via the Diagnostics page...
CVE-2024-42756
CVE-2024-42756 affects Netgear DGN1000WW v1.1.00.45, with a remote code execution flaw exploitable via the Diagnostics page. The root cause is described as incorrect code generation management. Impact is: attacker can execute arbitrary commands. Mitigation offered in connected material is to upgr...
PT-2024-8677 · NetGear · Netgear Dgn1000
Name of the Vulnerable Software and Affected Versions: Netgear DGN1000WW version 1.1.00.45 Description: The issue in Netgear DGN1000WW allows a remote attacker to execute arbitrary code via the Diagnostics page. This is related to incorrect code generation management. Exploitation of the issue ma...
CVE-2023-43890
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability in the diagnostic tools page. This vulnerability is exploited via a crafted HTTP request...
Linksys AX3200 V1.1.00 - Command Injection
Exploit Title: Linksys AX3200 V1.1.00 - Command Injection Date: 2022-09-19 Exploit Author: Ahmed Alroky Author: Linksys Version: 1.1.00 Authentication Required: YES CVE : CVE-2022-38841 Tested on: Windows Proof Of Concept: 1 - login into AX3200 webui 2 - go to diagnostics page 3 - put...
CloudBees Jenkins Active Directory Plugin Authorization Issue Vulnerability (CNVD-2020-61922)
CloudBees Jenkins Hudson Labs is the United States CloudBees company's set of Java-based development of continuous integration tools . The product is mainly used to monitor the continuous software version release/testing projects and some timed tasks . Active Directory Plugin is used in which an...
iBall iB-WRA150N Multiple Vulnerabilities
Exploit for hardware platform in category web applications Vulnerabilities summary The following advisory describes two 2 vulnerabilities found in iB-WRA150N devices, firmware 1.2.6 build 110401 Rel.47776n. iB-WRA150N is “a powerful solution to Internet connectivity at home, small offices and wor...
Design/Logic Flaw
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices allow remote authenticated users to execute arbitrary OS commands via shell metacharacters in the ping test arguments on the Diagnostics page...
CVE-2018-6388
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices allow remote authenticated users to execute arbitrary OS commands via shell metacharacters in the ping test arguments on the Diagnostics page...
CVE-2018-6388
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices allow remote authenticated users to execute arbitrary OS commands via shell metacharacters in the ping test arguments on the Diagnostics page...
CVE-2018-6388
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices allow remote authenticated users to execute arbitrary OS commands via shell metacharacters in the ping test arguments on the Diagnostics page...
iBall WRA150N - Multiple Vulnerabilities
iBall WRA150N - Multiple Vulnerabilities Vulnerabilities summary The following advisory describes two 2 vulnerabilities found in iB-WRA150N devices, firmware 1.2.6 build 110401 Rel.47776n. iB-WRA150N is “a powerful solution to Internet connectivity at home, small offices and work stations. The ke...