31761 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56704)
9p/xen: A fix release of IRQ Kernel logs indicate an IRQ was double- freed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504663;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41089)
drm/nouveau/dispnv04: null pointer dereference in nv17tvgethdmodes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504576; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49895)
drm/amd/display: vulnerability caused by adding a check to ensure the index 'i' is within bounds before accessing transfer function points in cmhelpertranslatecurvetodegammahwformat, preventing buffer overflow errors. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56739)
rtc: check if rtcreadtime was successful in rtctimerdowork If the rtcreadtime call fails, the struct rtctime tm; may contain uninitialized data, or an illegal date/time read from the RTC hardware. When calling rtctmtoktime later, the result may be a very large value possibly KTIMEMAX. If there ar...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46755)
wifi: mwifiex: Do not return unused priv in mwifiexgetprivbyid. mwifiexgetprivbyid returns the priv pointer corresponding to the bssnum and bsstype, but without checking if the priv is actually currently in use. Unused priv pointers do not have a wiphy attached to them which can lead to NULL...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50082)
blk-rq-qos: vulnerability in blk-rq-qos can cause a crash due to a race condition between rqqoswait and rqqoswakefunction, which is fixed by ensuring the waitqueue entry is accessed in the correct order. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56562)
i3c: master: miss free initdynaddr at i3cmasterputi3caddrs. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504562; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40983)
tipc: possible crash before doing decryption. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504584; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50268)
usb: typec: fix potential out of bounds in ucsiccgupdatesetnewcamcmd. The cmd variable can be controlled by the user via debugfs. That means newcam can be as high as 255 while the size of the uc-updated array is UCSIMAXALTMODES 30. The call tree is: ucsicmd // val comes from simpleattrwritexsigne...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53104)
media: uvcvideo: Skip parsing frames of type UVCVSUNDEFINED in uvcparseformat This can lead to out of bounds writes since frames of this type were not taken into account when calculating the size of the frames buffer in uvcparsestreaming. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-45008)
Input: missing limit on max slots results in too large allocation at inputmtinitslots. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504733;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49957)
ocfs2: null-ptr-deref when journal load failed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504593; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56746)
fbdev: sh7760fb: vulnerability involves a potential memory leak in sh7760fballocmem where sh7760fbfreemem does not release memory correctly if info-screenbase is not ready, which is fixed by calling dmafreecoherent instead. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50013)
exfat: memory leak in exfatloadbitmap If the first directory entry in the root directory is not a bitmap directory entry, 'bh' will not be released and reassigned, which will cause a memory leak. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
METZ CONNECT多款产品 安全漏洞
METZ CONNECT Energy-Controlling EWIO2-M and others are products of METZ CONNECT, Germany.METZ CONNECT Energy-Controlling EWIO2-M is a high performance data logger.METZ CONNECT Energy- Controlling EWIO2-M-BM is a high performance data logger.METZ CONNECT Ethernet-IO EWIO2-BM is a sensor and actuat...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42092)
gpio: davinci: There can be out of chips-irqs array boundaries access in davincigpioprobe. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504610;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46702)
thunderbolt: Mark XDomain as unplugged when router is removed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504670; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50267)
USB: serial: ioedgeport: fix use after free in debug printk The devdbg&urb-dev-dev, ... which happens after usbfreeurburb is a use after free of the urb pointer. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41041)
udp: small race window. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504778; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56615)
bpf: OOB devmap writes when deleting elements against XSKMAP which also applies to DEVMAP - the index used for accessing map entry, due to being a signed integer, causes the OOB writes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...