758 matches found
CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2022-4992
CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25722
The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...
CVE-2019-25722
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
EUVD-2019-20156
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
PT-2026-45739
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...
CVE-2019-25716
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...
Astra Linux - уязвимость в linux-5.10
In the Linux kernel, the following vulnerability has been resolved: octeonep: Fixed the issue where the host would hang during device reboot. When the host loses heartbeat messages from the device, the driver calls the device-specific ndostop function, which frees the resources. If the driver is...
TP-Link WR841N Router multiple vulnerabilities
RISK EVALUATION Multiple TP-Link products TP-Link Archer C20 V5, Archer C20 6.0, Archer AX53 v1.0 and TL-WR841N v13 are affected by multiple vulnerabilities. The most severe of these vulnerabilities could allow an adjacent, unauthenticated attacker to execute administrative commands. 2...
CVE-2026-5039
TP-Link TL-WR841N v13 uses DES-CBC encryption in the TDDPv2 debug protocol with a cryptographic key derived from default web management credentials, making the key predictable if device is left in default configuration. A network-adjacent attacker can exploit this weakness to gain unauthorized...
PT-2026-35507
A null pointer dereference vulnerability exists in the RTSP service of the MERCURY MIPC252W 1.0.5 Build 230306 Rel.79931n. During the processing of a SETUP request for the path rtsp://:554/stream1/track2, the device fails to properly validate the Transport header field. When this header is...
EUVD-2026-25899
A null pointer dereference vulnerability exists in the RTSP service of the MERCURY MIPC252W 1.0.5 Build 230306 Rel.79931n. During the processing of a SETUP request for the path rtsp://:554/stream1/track2, the device fails to properly validate the Transport header field. When this header is...
CVE-2026-31256
The CVE-2026-31256 entry describes a null pointer dereference in the RTSP service of the MERCURY MIPC252W (1.0.5 Build 230306 Rel.79931n). During processing of a SETUP request to rtsp://:554/stream1/track2, improper validation of the Transport header can cause a NULL pointer dereference in reques...