Lucene search
K

811 matches found

NVD
NVD
added 2026/06/16 10:16 a.m.6 views

CVE-2026-10825

A denial-of-service vulnerability exists in the WebSocket API due to insufficient validation and handling of JSON-based requests. A low-privileged authenticated attacker can send a specially crafted request that causes service disruption and may result in an unexpected device reboot...

7.1CVSS0.0031EPSS
Exploits0References1
EUVD
EUVD
added 2026/06/16 8:51 a.m.5 views

EUVD-2026-37043

A denial-of-service vulnerability exists in the WebSocket API due to insufficient validation and handling of JSON-based requests. A low-privileged authenticated attacker can send a specially crafted request that causes service disruption and may result in an unexpected device reboot...

7.1CVSS5.3AI score0.0031EPSS
Exploits0References1
Cvelist
Cvelist
added 2026/06/16 8:51 a.m.24 views

CVE-2026-10825 Improper JSON Input Validation in WebSocket API Leads to Denial of Service

A denial-of-service vulnerability exists in the WebSocket API due to insufficient validation and handling of JSON-based requests. A low-privileged authenticated attacker can send a specially crafted request that causes service disruption and may result in an unexpected device reboot...

7.1CVSS0.0031EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2026/06/05 7:19 p.m.7 views

CVE-2026-1871

TP-Link Tapo C200 v5 contains a stack-based buffer overflow flaw in RTSP authentication handling due to improper validation of Authorization header field lengths, which can be triggered by a crafted authentication request. Successful exploitation causes the affected RTSP core service process to...

7.1CVSS5.9AI score0.00305EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2026/06/03 4:56 p.m.6 views

CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score0.00199EPSS
Exploits0References2
Cvelist
Cvelist
added 2026/06/02 9:6 p.m.31 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.0016EPSS
Exploits0References2
CVE
CVE
added 2026/06/02 9:6 p.m.16 views

CVE-2022-4992

CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...

8.8CVSS5.8AI score0.0016EPSS
Exploits0References2
NVD
NVD
added 2026/06/02 8:16 p.m.9 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00187EPSS
Exploits0References2
Cvelist
Cvelist
added 2026/06/02 7:11 p.m.32 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00175EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2026/06/02 6:44 p.m.5 views

CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00193EPSS
Exploits0References2
CVE
CVE
added 2026/06/02 6:44 p.m.11 views

CVE-2019-25722

The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...

7.6CVSS5.9AI score0.00193EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2026/06/02 6:44 p.m.7 views

CVE-2019-25722

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00193EPSS
Exploits0References4
ATTACKERKB
ATTACKERKB
added 2026/06/02 2:0 p.m.7 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References4
Cvelist
Cvelist
added 2026/06/02 2:0 p.m.37 views

CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS0.00132EPSS
Exploits0References2
EUVD
EUVD
added 2026/06/02 2:0 p.m.12 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2026/06/02 12:0 a.m.10 views

PT-2026-45739

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
Exploits0References3
ATTACKERKB
ATTACKERKB
added 2026/06/01 9:15 p.m.6 views

CVE-2019-25716

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS5.8AI score0.002EPSS
Exploits0References4
Cvelist
Cvelist
added 2026/06/01 9:15 p.m.28 views

CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.002EPSS
Exploits0References2
ICS
ICS
added 2026/04/29 2:27 p.m.4 views

TP-Link WR841N Router multiple vulnerabilities

RISK EVALUATION Multiple TP-Link products TP-Link Archer C20 V5, Archer C20 6.0, Archer AX53 v1.0 and TL-WR841N v13 are affected by multiple vulnerabilities. The most severe of these vulnerabilities could allow an adjacent, unauthenticated attacker to execute administrative commands. 2...

8.8CVSS5.7AI score0.00401EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2026/04/29 1:44 a.m.5 views

CVE-2026-5039

TP-Link TL-WR841N v13 uses DES-CBC encryption in the TDDPv2 debug protocol with a cryptographic key derived from default web management credentials, making the key predictable if device is left in default configuration. A network-adjacent attacker can exploit this weakness to gain unauthorized...

8.8CVSS5.3AI score0.0013EPSS
Exploits0References1
Rows per page