Lucene search
+L

713 matches found

NVD
NVD
added 2020/09/01 9:15 p.m.23 views

CVE-2020-16208

The affected product is vulnerable to cross-site request forgery, which may allow an attacker to modify different configurations of a device by luring an authenticated user to click on a crafted link on the N-Tron 702-W / 702M12-W all versions...

9.3CVSS8.8AI score0.01238EPSS
SaveExploits1References3
Metasploit
Metasploit
added 2020/08/20 5:41 p.m.18 views

Arista Configuration Importer

This module imports an Arista device configuration. Module Options msf use auxiliary/admin/networking/aristaconfig msf auxiliaryaristaconfig show actions ...actions... msf auxiliaryaristaconfig set ACTION msf auxiliaryaristaconfig show options ...show and set options... msf auxiliaryaristaconfig...

7.1AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2020/08/20 12:00 a.m.9 views

The vulnerability of software for configuring devices and monitoring SoMove metrics, related to errors in using standard permissions, allows a perpetrator to increase their privileges.

The vulnerability of software for configuring devices and monitoring SoMove metrics is related to errors in the use of standard permissions. Exploiting this vulnerability can allow an attacker to enhance their privileges...

4CVSS7.2AI score0.00327EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2020/07/16 6:15 p.m.30 views

CVE-2020-3150

A vulnerability in the web-based management interface of Cisco Small Business RV110W and RV215W Series Routers could allow an unauthenticated, remote attacker to download sensitive information from the device, which could include the device configuration. The vulnerability is due to improper...

5.9CVSS0.015EPSS
SaveExploits0References1
Prion
Prion
added 2020/07/16 6:15 p.m.26 views

Authorization

A vulnerability in the web-based management interface of Cisco Small Business RV110W and RV215W Series Routers could allow an unauthenticated, remote attacker to download sensitive information from the device, which could include the device configuration. The vulnerability is due to improper...

4.3CVSS5.6AI score0.015EPSS
SaveExploits0References1Affected Software2
NVD
NVD
added 2020/07/02 5:15 a.m.26 views

CVE-2020-3391

A vulnerability in Cisco Digital Network Architecture DNA Center could allow an authenticated, remote attacker to view sensitive information in clear text. The vulnerability is due to insecure storage of certain unencrypted credentials on an affected device. An attacker could exploit this...

6.5CVSS0.01307EPSS
SaveExploits0References1
Prion
Prion
added 2020/07/02 5:15 a.m.19 views

Design/Logic Flaw

A vulnerability in Cisco Digital Network Architecture DNA Center could allow an authenticated, remote attacker to view sensitive information in clear text. The vulnerability is due to insecure storage of certain unencrypted credentials on an affected device. An attacker could exploit this...

4CVSS6.3AI score0.01307EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/07/02 4:20 a.m.67 views

CVE-2020-3391

Cisco DNA Center Information Disclosure (CVE-2020-3391): An authenticated remote attacker could view credentials stored insecurely, by accessing device configuration. Affected product: Cisco DNA Center. Root cause: insecure storage of unencrypted credentials. Impact: potential exposure of credent...

6.5CVSS6.3AI score0.01307EPSS
SaveExploits0References1Affected Software1
Metasploit
Metasploit
added 2020/06/21 8:41 p.m.56 views

Ubiquiti Configuration Importer

This module imports an Ubiquiti device configuration. The db file within the .unf backup is the data file for Unifi. This module can take either the db file or .unf. This module requires Metasploit: https://metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework...

7.4AI score
SaveExploits0
NVD
NVD
added 2020/06/10 5:15 p.m.33 views

CVE-2020-7589

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated...

9.1CVSS0.0199EPSS
SaveExploits0References2
CVE
CVE
added 2020/06/10 4:24 p.m.89 views

CVE-2020-7589

CVE-2020-7589 affects Siemens LOGO! 8 BM (including SIPLUS variants). The root cause is missing authentication for a critical function, allowing an unauthenticated attacker with network access to Port 135/TCP to read/modify device configuration and access project files, impacting confidentiality ...

9.1CVSS8.9AI score0.0199EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/06/10 4:24 p.m.37 views

CVE-2020-7589

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated...

9.1AI score0.0199EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2020/06/10 12:00 a.m.11 views

The vulnerability of the microprogrammed control module software for Schneider Electric Easergy T300 (HU250) automation systems in transformer substations lies in the storage and transmission of critical data in unencrypted form. This allows a intruder to obtain information about the device’s configuration.

The vulnerability of the microprogrammed control module software for Schneider Electric Easergy T300 HU250 automation systems in transformer substations relates to the storage and transmission of critical data in unencrypted form. Exploiting this vulnerability could allow an attacker, operating...

7.8CVSS7.2AI score0.00815EPSS
SaveExploits0References2Affected Software1
Cisco
Cisco
added 2020/06/03 4:00 p.m.28 views

Cisco IOS XE Software Web UI Command Injection Vulnerability

A vulnerability in the web-based user interface web UI of Cisco IOS XE Software could allow an authenticated, remote attacker with read-only privileges to inject IOS commands to an affected device. The injected commands should require a higher privilege level in order to be executed. The...

8.8CVSS2.3AI score0.01812EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/02 6:31 p.m.44 views

CVE-2020-12017

GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute...

10AI score0.02331EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/05/08 12:00 a.m.12 views

WAVLINK WL-WN530HG4 Information Disclosure Vulnerability

WAVLINK WL-WN530HG4 is a wireless network signal extender from China RuiYin Technology WAVLINK. A security vulnerability exists in the /cgi-bin/ExportALLSettings.sh file in WAVLINK WL-WN530HG4 M30HG4.V5030.191116 version. An attacker can exploit this vulnerability with the help of a specially...

7.5CVSS6.6AI score0.07552EPSS
SaveExploits0References1
OSV
OSV
added 2020/05/07 6:15 p.m.7 views

CVE-2020-10974

An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3,...

7.5CVSS5.8AI score0.01685EPSS
SaveExploits0References4
Prion
Prion
added 2020/05/07 6:15 p.m.18 views

Information disclosure

An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3,...

5CVSS7.6AI score0.01685EPSS
SaveExploits0References4Affected Software2
CVE
CVE
added 2020/05/07 5:42 p.m.65 views

CVE-2020-10974

The CVE-2020-10974 entry describes an information-disclosure flaw in a device backup feature: a crafted POST request can return the current device configuration in cleartext, including the administrator password, without any authentication. Affected devices include WAVLINK WN575A3, WN579G3, WN531...

7.5CVSS7.5AI score0.01685EPSS
SaveExploits0References4Affected Software1
OSV
OSV
added 2020/04/27 3:15 p.m.9 views

CVE-2020-12266

An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed...

7.5CVSS7.1AI score0.01722EPSS
SaveExploits0References5
Rows per page