15 matches found
CVE-2020-12733
Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...
EUVD-2020-5021
Malware in sbrugna...
CVE-2020-12732
DEPSTECH WiFi Digital Microscope 3 has a default SSID of Jetionxxxxxxxx with a password of 12345678...
CVE-2020-12733
Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...
CVE-2020-12734
DEPSTECH WiFi Digital Microscope 3 allows remote attackers to change the SSID and password, and demand a ransom payment from the rightful device owner, because there is no way to reset to Factory Default settings...
Design/Logic Flaw
Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...
CVE-2020-12732
DEPSTECH WiFi Digital Microscope 3 has a default SSID of Jetionxxxxxxxx with a password of 12345678...
CVE-2020-12733
Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...
CVE-2020-12734
DEPSTECH WiFi Digital Microscope 3 allows remote attackers to change the SSID and password, and demand a ransom payment from the rightful device owner, because there is no way to reset to Factory Default settings...
PT-2021-9470
Name of the Vulnerable Software and Affected Versions DEPSTECH WiFi Digital Microscope version 3 Description The issue concerns the use of a default SSID and password in the WiFi Digital Microscope 3. The default SSID is 'Jetion xxxxxxxx' with a password of '12345678'. Recommendations For DEPSTEC...
PT-2021-9471
Name of the Vulnerable Software and Affected Versions DEPSTECH WiFi Digital Microscope 3 affected versions not specified Description The issue allows a TELNET connection with the molinkadmin password for the molink account. This is related to Certain Shenzhen PENGLIXIN components used by Shekar...
PT-2021-9472
Name of the Vulnerable Software and Affected Versions DEPSTECH WiFi Digital Microscope version 3 Description The issue allows remote attackers to change the SSID and password of the device, potentially leading to a ransom demand from the rightful device owner. This is due to the lack of a reset...
CVE-2020-12732: Initialization of a Resource with an Insecure Default
DEPSTECH WiFi Digital Microscope 3 has a default SSID of Jetionxxxxxxxx with a password of 12345678...
CVE-2020-12733: Incorrect Authorization
Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account...
CVE-2020-12734: Missing Authorization
DEPSTECH WiFi Digital Microscope 3 allows remote attackers to change the SSID and password, and demand a ransom payment from the rightful device owner, because there is no way to reset to Factory Default settings...