Lucene search
+L

4140 matches found

ICS
ICS
added 2022/11/10 12:00 a.m.61 views

Delta Electronics DIAEnergie

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: DIAEnergie --------- Begin Update B part 1 of 5 --------- Vulnerabilities: Cross-site Scripting, SQL Injection, Authorization Bypass --------- End Update B part 1 of 5...

8.8CVSS8.7AI score0.26572EPSS
SaveExploits0References5
The Hacker News
The Hacker News
added 2022/11/04 10:01 a.m.150 views

CISA Warns of Critical Vulnerabilities in 3 Industrial Control System Software

The U.S. Cybersecurity and Infrastructure Security Agency CISA has published three Industrial Control Systems ICS advisories about multiple vulnerabilities in software from ETIC Telecom, Nokia, and Delta Industrial Automation. Prominent among them is a set of three flaws affecting ETIC Telecom's...

2.9AI score0.02283EPSS
SaveExploits0
CNNVD
CNNVD
added 2022/11/04 12:00 a.m.9 views

Delta Electronics Industrial Automation DIALink 路径遍历漏洞

Delta Electronics Industrial Automation DIALink is an industrial automation IoT device from Delta Electronics of Taiwan, China. A path traversal vulnerability exists in Delta Electronics Industrial Automation DIALink because it uses external input to construct a pathname that identifies a file or...

8.1CVSS7.6AI score0.02283EPSS
SaveExploits0References3
CISA
CISA
added 2022/11/03 12:00 a.m.10 views

CISA Releases Three Industrial Control Systems Advisories

CISA has released three 3 Industrial Control Systems ICS advisories on November 3, 2022. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories f...

2.5AI score
SaveExploits0References3
ICS
ICS
added 2022/11/03 12:00 a.m.40 views

Delta Industrial Automation DIALink

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Industrial Automation Equipment: DIALink Vulnerability: Path traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to place malicious code on the...

8.1CVSS7.8AI score0.02283EPSS
SaveExploits0References5
NVD
NVD
added 2022/10/31 8:15 p.m.27 views

CVE-2022-41644

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges...

8.8CVSS0.00732EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.12 views

CVE-2022-41779

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote...

9.8CVSS6AI score0.01138EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.10 views

CVE-2022-41776

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrativ...

7.5CVSS5.8AI score0.00545EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.13 views

CVE-2022-41657

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces APIs. This could create arbitrary files, which could be used in API operations and could ultimately...

9.8CVSS6.1AI score0.20898EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.45 views

CVE-2022-41776

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrativ...

7.5CVSS0.00545EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.25 views

CVE-2022-41779

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote...

9.8CVSS0.01138EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.37 views

CVE-2022-41629

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as...

9.1CVSS0.00628EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.20 views

CVE-2022-41772

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution...

9.8CVSS0.24945EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.12 views

CVE-2022-41772

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution...

9.8CVSS6AI score0.24945EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.79 views

CVE-2022-41657

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces APIs. This could create arbitrary files, which could be used in API operations and could ultimately...

9.8CVSS0.20898EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.32 views

CVE-2022-41688

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to th...

9.8CVSS0.00682EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.10 views

CVE-2022-41629

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as...

9.1CVSS5.8AI score0.00628EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.33 views

CVE-2022-38142

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization...

9.8CVSS0.18212EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.33 views

CVE-2022-40202

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication...

9.8CVSS0.01342EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.13 views

CVE-2022-40202

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication...

9.8CVSS6AI score0.01342EPSS
SaveExploits0References1
Rows per page
Query Builder