4143 matches found
MAL-2025-37533 Malicious code in ugli-delta-charlie-yuiof (npm)
The package ugli-delta-charlie-yuiof was found to contain malicious code...
MAL-2025-30427 Malicious code in project-oovdk-delta (npm)
The package project-oovdk-delta was found to contain malicious code...
MAL-2025-38317 Malicious code in victor-kiwi-delta-wqevr (npm)
The package victor-kiwi-delta-wqevr was found to contain malicious code...
MAL-2025-39804 Malicious code in xigua-delta-xbyl (npm)
The package xigua-delta-xbyl was found to contain malicious code...
MAL-2025-40149 Malicious code in yam-delta-ivqo (npm)
The package yam-delta-ivqo was found to contain malicious code...
MAL-2025-31944 Malicious code in redshift-delta-8zf3 (npm)
The package redshift-delta-8zf3 was found to contain malicious code...
MAL-2025-18213 Malicious code in delta-charlie-bylt (npm)
The package delta-charlie-bylt was found to contain malicious code...
MAL-2025-39933 Malicious code in xray-delta-dyhf (npm)
The package xray-delta-dyhf was found to contain malicious code...
MAL-2025-20668 Malicious code in flare-delta-dz9g (npm)
The package flare-delta-dz9g was found to contain malicious code...
MAL-2025-18255 Malicious code in delta-watermelon-umxw (npm)
The package delta-watermelon-umxw was found to contain malicious code...
MAL-2025-38306 Malicious code in victor-delta-kilo-lxsvv (npm)
The package victor-delta-kilo-lxsvv was found to contain malicious code...
MAL-2025-32040 Malicious code in reject-stub-nu-long-delta (npm)
The package reject-stub-nu-long-delta was found to contain malicious code...
Delta Electronics DIAView Directory Traversal Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Electronics DIAView. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web service, which listens on TCP port 80 by default. The issue...
Delta Electronics DIAView Directory Traversal Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DIAView. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web service, which listens on TCP port 80 by default. The issue results fr...
Delta Electronics DIAView Catalog Traversal Vulnerability
Delta Electronics DIAView is an industrial configuration software from Delta Electronics China. A directory traversal vulnerability exists in Delta Electronics DIAView, which stems from a lack of validity checking of paths used by the program to process directory requests, and can be exploited by...
CISA Releases Ten Industrial Control Systems Advisories
CISA released ten Industrial Control Systems ICS advisories on August 7, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-219-01 Delta Electronics DIAView ICSA-25-219-02 Johnson Controls FX80 and FX90...
Delta Electronics DIAView
RISK EVALUATION Successful exploitation of this vulnerability may allow a remote attacker to read or write files on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations...
PT-2025-31895 · Daview · Diaview
Name of the Vulnerable Software and Affected Versions: DIAView versions prior to 4.2.0 Description: DIAView software contains a directory traversal flaw that could lead to information disclosure. Recommendations: Update DIAView to a version later than 4.2.0...
Delta Electronics DIAView 安全漏洞
Delta Electronics DIAView is an industrial configuration software from Delta Electronics China. A directory traversal vulnerability exists in Delta Electronics DIAView, which stems from a lack of validity checking of paths used by the program to process directory requests, and can be exploited by...
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on July 29, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-210-01 National Instruments LabVIEW ICSA-25-210-02 Samsung HVAC DMS ICSA-25-210-03 Delta...